LC8300

3 in OD Through-Hole, Compression Load Cells

  • 5 Point NIST Traceable Calibration with
    59 kOhm Shunt Cal Data
  • Low Profile
  • All Stainless Steel Construction
  • Rugged Industrial Design
LC8300
From TWD 31,484
3 in OD Through-Hole, Compression Load Cells LC8300 LC8300
loading all models
Product Overview
  • 5-Point Calibration 0%, 50%, 100%, 50%, 0%
  • Cable Length 5 ft
  • Calibration Option 5 POINT NIST
  • Electrical Connection Cable
  • Electrical Output 2 mV/V
  • Force Type Compression
  • Full Scale Deflection 0.003 in
  • Height 1 in
  • Input Resistance 360 Ω min
  • Linearity ± 0.5%
  • Load Cell Type Through Hole
  • Materials 17-4 PH Stainless Steel
  • Operating Temperature, Max 121 °C
  • Operating Temperature, Min -54 °C
  • Outer Diameter 3 in
  • Output Resistance 350 ± 5 Ω
  • Overload, Max 300% FS
  • Process Temperature, Max 71 °C
  • Process Temperature, Min 16 °C
  • Repeatability ± 0.1%
  • Safe Overload 150% FS
  • Series ID LC8300
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect ± 0.018% rdg/°C
  • Thermal Zero Effect ± 0.009% FSO/°C
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error ± 2%

Supported Applications

The Omega LC8300 Series consists of compact, through-hole compression load cells designed for measuring compressive forces. The series is engineered with a low profile and rugged industrial design suitable for applications including clamping forces and bolt loading.

Operating Conditions & Performance

The LC8300 operates within an ambient temperature range of 16 to 71°C (60 to 160°F) and a process temperature range of -54 to 121°C (-65 to 250°F). The load cells feature a nominal output signal of 2 mV/V with an excitation voltage requirement of 10 Vdc, up to a maximum of 15V. Performance specifications include an accuracy class of ±0.5% FSO and repeatability of ±0.1% FSO.

Thermal effects are specified as Zero: ±0.009% FSO/°C and Span: ±0.018% FSO/°C, with a zero balance tolerance of ±2.0% FSO. Each unit is supplied complete with 5-point NIST-traceable calibration data and includes 59 kΩ shunt data.

Physical Dimensions

  • Overall Height (H): 25.4 mm (1.00")
  • Outer Diameter (OD): 76.3 mm (3.00")

Configuration Options

The LC8300 series offers a wide selection of configurations defined by capacity and inside diameter (ID). The load cells are constructed from 17-4 PH stainless steel housing material.

Capacity Ranges

  • Imperial: 0 to 1,000 lb through 0 to 100,000 lb
  • Metric: 0 to 455 kgf through 0 to 45,372 kgf

Selectable Inside Diameters (ID)

The series supports selectable inside diameters ranging from 0.250" to 1.50", allowing integration into existing mechanical assemblies with specific bore requirements.

  • Available ID sizes include: 0.250", 0.375", 0.500", 0.625", 0.750", 0.875", 0.938", 1.00", 1.13", 1.25", 1.38", and 1.50".

Electrical Connection & Compliance

  • Cable: Includes a 1.5 m (5') 4-conductor shielded cable.
  • Wire Color Code: Green (+Output), White (-Output), Black (-Input), Red (+Input).
  • Approvals: NIST and RoHS compliant.