Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

CN8200-Series

1/16 DIN Universal Input Autotune Controller with Ramp & Soak

Models In Stock
  • Field-Configurable Universal Inputs
  • Autotuning, Direct or Reverse-Acting for Both Outputs
  • User-Selectable Ramp to Setpoint
  • 8 Ramp and 8 Soak Segments
CN8200-Series
From TWD 18,553
Models In Stock
1/16 DIN Universal Input Autotune Controller with Ramp & Soak CN8200-Series CN8200-Series
loading all models
Product Overview
  • Accuracy ± 0.2 %
  • Accuracy Detail ± 0.2% FS, ± 1 digit
  • CMRR 100 dB
  • Cold Junction Compensation 0.05°C/°C ambient
  • Contacts Twin bifurcated
  • Control Characteristics Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel
  • Cutout Dimensions 45 x 45 mm
  • Depth Behind Panel 100 mm
  • Display Size 9.2 mm (.36 in)
  • Display Type 4 Digit LED
  • Display Type Note Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36")
  • Electrical Connection Screw Terminal
  • Enclosure Ratings IP65, NEMA Type 4X
  • Events/Alarms 1 to 8
  • Form factor 1/16 DIN
  • Hardware and Software Requirements, Min CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers
  • Height 53.3 mm
  • Input Type Thermocouple, RTD, mA, Voltage
  • Input Type Note Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable
  • Length 8.21 mm
  • Loops 0 to 99
  • Measurement Type Current, Temperature, Voltage
  • Measuring Range Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable
  • Memory Backup Solid State
  • Number of Inputs 1
  • Operating Temperature, Max 55 °C
  • Operating Temperature, Min 0 °C
  • Ramp and Soak 8 Ramp & Soak
  • Ramp Setpoint 1 to 9999 minutes
  • Ramp/Soak Time 0 to 9999 minutes
  • Relative Humidity 90% RH, non-condensing
  • Repeatability ± 1 count
  • Sampling Rate 10 Hz (10 updates/second)
  • Series ID CN8200-Series
  • Series Mode Rejection >70 dB
  • Setpoint Resolution 1 count/0.1 count
  • Supply Power Note 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional)
  • Temperature Stability 5 μV/°C Max
  • Weight 226 g
  • Width 53.3 mm

Supported Applications

The Omega CN8200 Series comprises 1/16 DIN universal temperature and process controllers designed for applications requiring precise autotuning, ramp-to-setpoint control, and multi-segment programming. The series supports field-configurable universal inputs including thermocouples (J, K, T, N, R, S, B, C, E), RTDs (3-wire 100 Ω Pt), Platinel II, voltage, current, and millivolt signals.

Key functional capabilities include:

  • Ramp/Soak Control: Configurable for up to 8 ramp segments followed by 8 soak segments.
  • Dual Display: Simultaneous Process Value (PV) and Setpoint (SV) indication with individual status LEDs.
  • Remote Monitoring: Compatible with CN8-SW software for remote monitoring and control via RS232/485 communications options.

Operating Conditions & Performance

The controller operates within an ambient temperature range of 0 to 55°C (32 to 131°F) at a maximum humidity of 90% RH, non-condensing. The front panel features a NEMA 4X (IP65) enclosure rating.

Performance specifications include:

  • Accuracy: ±0.2% FS, ±1 digit for rated accuracy conditions.
  • Response Time: 10 Hz (100 ms).
  • Hysteresis: Adjustable from 1 to span of sensor.
  • Resolution: 1 count or 0.1 count depending on range selection.

The series supports a wide array of measurement ranges, including -270 to 1354°C (-454 to 2469°F) for specific thermocouple types and scalable electrical inputs from -1999 to 9999. Load resistance is limited to 100 Ω maximum for rated accuracy on analog outputs.

Configuration Options

Power Supply Options

The standard power supply supports a universal range of 100 to 250 Vac and 120 to 250 Vdc. An optional low-voltage configuration (-LV suffix) is available for 24 Vac/24 Vdc operation.

Input Types

The universal input capability covers the following sensor types:

  • Thermocouples: J, K, T, N, R, S, B, C, E (including CHROMEGA®-ALOMEGA®, OMEGALLOY®, and W/5%Re-W/26%Re).
  • RTDs: 3-wire 100 Ω Pt.
  • Analog Signals: Voltage (0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V), Current (4 to 20 mA, 0 to 20 mA), and Millivolt ranges.

Output Configurations

The series is available in single-output (CN8201) or dual-output (CN8202) models. Output types include:

  • Mechanical Relay: 5 A @ 120 Vac, 3 A @ 240 Vac.
  • Solid State Relay (SSR): 1 A continuous, 10 A surge @ 25°C.
  • DC Pulse: 20 Vdc pulse output.
  • Analog Current/Voltage: 4 to 20 mA (up to 800 Ω or 1000 Ω maximum depending on suffix), 0 to 5V, 0 to 10V, and various mV ranges.

Additional Options

The series supports a single additional option per controller. Available options include:

  • Alarms: Single-alarm mechanical relay (-AL1), dual alarms with AC SSR (-AL2), or dual DC level alarms at 24 Vdc (-AL3).
  • Communications: RS232 (-C2) or RS485 (-C4). The -C4 option can be configured for MODBUS® protocol and includes variants with digital inputs (switch closed, switch open, or 0/5V logic).
  • Remote Setpoint: Switch-based or voltage-based remote setpoints.
  • Transducer Excitation: Available at 15 Vdc (-XP1), 12 Vdc (-XP2), 10 Vdc (-XP3), or 5 Vdc (-XP4).

Key Product Differences

The CN8200 Series is differentiated by model number and output configuration:

  • CN8201-(-*): Single-output ramp/soak controller.
  • CN8202-(-*)-(-*): Dual-output ramp/soak controller, allowing independent selection of first and second output types (e.g., Relay + SSR).

The ordering suffix structure defines the specific configuration: <MODEL> - <FIRST OUTPUT SUFFIX> - <SECOND OUTPUT SUFFIX> - <LOW VOLTAGE SUFFIX> - <ADDITIONAL OPTION SUFFIX>. For example, a dual-output model with DC pulse and relay outputs configured for low voltage and an alarm would follow the pattern CN8202-DC1-R2-LV-AL3.

The series includes UL US and C UL US approvals. A 2-year warranty is standard, with OMEGACARE™ extended warranty programs available.