Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
CN8201-F1
1/16 Din Universal Temperature & Process Controllers with 8 Segment Ramp/Soak Capability
Choose a Variant
Control Output
Supply Voltage
Remote Setpoint
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| Accuracy | ± 0.2 % |
| Accuracy Detail | ± 0.2% FS, ± 1 digit |
| CMRR | 100 dB |
| Cold Junction Compensation | 0.05°C/°C ambient |
| Contacts | Twin bifurcated |
| Control Characteristics | Set point Limits: Limited to configured range for thermocouple and RTD; limited to scaled range; Alarms: Adjustable for high/low; selectable process or deviation; Rate (Derivative): 0 to 2400 seconds; Reset (Integral): 0 to 9600 seconds; Cycle Time: 0.2 to 120 seconds; Proportional Band: 1 to span of sensor; Dead band: Negative span to positive span of sensor; Hysteresis: 1 to span of sensor; Autotune Damping: Adjustable (low, normal, or high); Ramp to Set point: 1 to 9999 minutes; Autotune: Operator-initiated from front panel; Manual Control: Operator-initiated from front panel |
| Control Output | Analog Curent |
| Cutout Dimensions | 45 x 45 mm |
| Data Interface | None |
| Depth Behind Panel | 100 mm |
| Display Size | 9.2 mm (.36 in) |
| Display Type | 4 Digit LED |
| Display Type Note | Dual LED—4-digit, orange: process display; green: menu/parameter display; 9.2 mm (0.36") |
| Electrical Connection | Screw Terminal |
| Enclosure Ratings | IP65, NEMA Type 4X |
| Events/Alarms | 1 to 8 |
| Form factor | 1/16 DIN |
| GrossWeightValue | 0.62 |
| Hardware and Software Requirements, Min | CN8-SW (Optional Software): Minimum Hardware and Software Requirements: IBM PC or 100% compatible, Windows 95/98/NT; RS485 interface or RS232 to RS485 converter; Software Compatibility: CN8200 Series controllers; Software Capability: Supports up to 254 CN8200 Series controllers |
| Height | 53.3 mm |
| Input Type | Thermocouple, RTD, mA, Voltage |
| Input Type Note | Input Type: See input table on next page Digital Input: For remote setpoint, remote standby or ramp/soak run and hold Thermocouple Lead Resistance: 100 Ω maximum for rated accuracy Decimal Position: Selectable |
| Length | 8.21 mm |
| Loops | 0 to 99 |
| Measurement Type | Current, Temperature, Voltage |
| Measuring Range | Type J (Iron-Constantan): -200 to 760°C, Type K (CHROMEGA®-ALOMEGA®): -270 to 1354°C, Type T (Copper-Constantan): -270 to 400°C, Type N (OMEGALLOY®) : -268 to 1300°C, Type R (Pt/13%Rh-Pt) : -50 to 1768°C, Type S (Pt/10%Rh-Pt) : -50 to 1768°C, Type B (Pt/30%Rh-Pt/6%Rh) : 0 to 1820°C, Type C (W/5%Re-W/26%Re) : 0 to 2315°C, Type E (CHROMEGA®-Constantan) : -150 to 1000°C, NNM 18% molybdenum vs nickel -06% cobalt : 0 to 1410°, Platinel II : -100 to 1232°C, RTD ((3-wire) 100 Ω Pt) : -200 to 850°C, RTD ((3-wire) 100 Ω Pt) : -199.9 to 375.0°C, 0 to 1V : Scalable (-1999 to 9999) selectable 1 to 5V : Scalable (-1999 to 9999) selectable 0 to 5V : Scalable (-1999 to 9999) selectable 0 to 10V : Scalable (-1999 to 9999) selectable 10 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 50 mV : Scalable (-1999 to 9999) selectable 0 to 10 mV : Scalable (-1999 to 9999) selectable 0 to 100 mV : Scalable (-1999 to 9999) selectable 4 to 20 mA : Scalable (-1999 to 9999) selectable 0 to 20 mA : Scalable (-1999 to 9999) selectable |
| Memory Backup | Solid State |
| Number of Control Outputs | 1 |
| Number of Inputs | 1 |
| Operating Temperature, Max | 55 °C |
| Operating Temperature, Min | 0 °C |
| Output Detail | 4 to 20mA (500 ohm max.);Output #1: Reverse- or direct-acting, configured from menu Output #2: Reverse- or direct-acting, configured from menu Mechanical Relay: Rated 5 A @120 Vac, 3 A @ 240 Vac, normally open (NO), normally closed (NC) (output 1); rated 5 A @120 Vac, 3 A @ 240 Vac, NO (output 2) Current: 4 to 20 mA, 500 Ω maximum (suffix F1, F2); 4 to 20 mA, 1000 Ω maximum (suffix FH1, FH2) Voltage: 20 Vdc pulse Solid State Relay: SSR, 120/240 Vac, zero voltage switched, rated 1 A continuous, 10 A surge @ 25°C (77°F) Transducer Power Supply: 5, 10, 12, 15 Vdc ± 10% ;Alarm Output:Mechanical relay rated 5 A @ 120 Vac, 3 A @ 240 Vac, NO; optically isolated SSR rated 1 A, 120/240 Vac @ 25°C (77°C); DC alarms, 24 Vdc |
| Output Signal | Current |
| Ramp Setpoint | 1 to 9999 minutes |
| Ramp and Soak | 8 Ramp & Soak |
| Ramp/Soak Time | 0 to 9999 minutes |
| Relative Humidity | 90% RH, non-condensing |
| Remote Setpoint | N/A |
| Repeatability | ± 1 count |
| Sampling Rate | 10 Hz (10 updates/second) |
| Series ID | CN8200-Series |
| Series Mode Rejection | >70 dB |
| Setpoint Resolution | 1 count/0.1 count |
| Supply Power Note | 100 to 250V, 50/60 Hz (single-phase); 120 to 250 Vdc, 24 Vac/24 Vdc (optional) |
| Supply Power Type | AC |
| Supply Voltage | 100 to 250 Vac |
| Temperature Stability | 5 μV/°C Max |
| Weight | 226 g |
| Width | 53.3 mm |
| Country of Origin | United States |
| See All Specs | |