Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here
LC302
0.75 in Diameter, Miniature Button Compression Load Cell
Models In Stock
- Small 0.75' (19 mm) Dia.
- Low 0.5' (13 mm) Profile
- Robotic and Test Bench Applications
- Built in Load Button for Easy Installation
LC302
From
TWD
19,802
Models In Stock
Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Accuracy ± 0.5 %
- Bridge Resistance 350 Ω
- Cable Length 5 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 1 mV/V
- Enclosure Ratings IP54
- Force Type Compression
- Full Scale Deflection 0.003 in
- Hysteresis ± 0.5%
- Linearity ± 0.5%
- Load Cell Type Button
- Materials Stainless Steel
- Operating Temperature, Max 107 °C
- Operating Temperature, Min -54 °C
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.5%
- Safe Overload 150% FS
- Series ID LC302
- Supply Power Note 5 Vdc, 15 Vdc max
- Supply Voltage 5 Vdc
- Thermal Span Effect 0.036% FSO/°C
- Thermal Zero Effect 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
Supported Applications
The Omega LC302 series comprises miniature button compression load cells designed for robotic and test bench applications. These sensors feature a low profile of 12.7 mm (0.50") height with an integrated built-in load button to facilitate easy installation in compact spaces.
Operating Conditions & Performance
The LC302 series delivers high accuracy performance with combined linearity, hysteresis, and repeatability of ±0.5% FSO. Each unit includes a 19 mm (0.75") diameter stainless steel housing rated IP54 for environmental protection.
- Measurement Range: Standard models cover 25 lb to 1,000 lb; Metric models range from 100 N to 5,000 N.
- Operating Temperature (Ambient): 16 to 71°C (60 to 160°F).
- Process Temperature: -54 to 107°C (-65 to 225°F).
- Excitation Voltage: 5 Vdc, with a maximum of 15 Vdc.
- Output Signal: Nominal 1 mV/V.
The series includes a built-in temperature compensation board and comes complete with 5-point NIST-traceable calibration data along with 59 kΩ shunt data for verification.
Configuration Options
The LC302/LCM302 Series is available in two distinct model families to accommodate different unit preferences, each offering specific capacity steps and compatible meter options.
Standard Models (LC302)
- Capacities: 25 lb (111 N), 50 lb (222 N), 100 lb (445 N), 250 lb (1,112 N), 500 lb (2,224 N), and 1,000 lb (4,448 N).
- Compatible Meters: DPiS, DP41-S, DP25B-S.
Metric Models (LCM302)
- Capacities: 100 N (22.5 lb), 200 N (45 lb), 500 N (112 lb), 1,000 N (225 lb), 2,000 N (450 lb), and 5,000 N (1,124 lb).
- Compatible Meters: iSeries, DP41-S, DP25B-S.
All variants feature a load resistance of 350 Ω minimum and are supplied with a 1.5 m (5') 4-conductor insulated cable for electrical connection.
Key Product Differences
The primary distinction within the series lies between the LC302 standard models, which prioritize pound-force capacities up to 1,000 lb, and the LCM302 metric models, which provide Newton-based ranges extending to 5,000 N. While both families share identical physical dimensions—19 mm (0.75") diameter with a spherical radius of 5.08 mm (0.200")—they differ in their specific capacity increments and the compatible meter series listed for each model number.