LVCN210-Series

Ultrasonic Level Transmitter and Controller

Models In Stock
  • Level Detection, Switch and Control Functions Up to 3 m (9.8')
  • Fast and Easy Configuration Via Free Software Download and USB Adaptor
  • Narrow 5.08 cm (2') Beam Width and Short 10 cm (4') Dead Band
  • Four Programmable Relays
LVCN210-Series
From C$ 1,082.18
Models In Stock
Ultrasonic Level Transmitter and Controller LVCN210-Series LVCN210-Series
loading all models
Product Overview
  • Accuratezza ± 0.2 %
  • Larghezza del raggio 2 in
  • Lunghezza cavo 48 in
  • Tipo di cavo Schermato isolato
  • Configurazione PC Windows® USB 2.0 gratuito. Il sensore di livello è configurabile tramite il nostro software PC gratuito e l'adattatore USB. I sensori sono offerti con e senza connettori USB. I connettori possono essere utilizzati per configurare molti prodotti di livello compatibili. Scarica la tua copia gratuita su
  • Sicurezza in caso di guasto dei contatti Interruzione di corrente: Mantieni ultimo
  • Interfaccia dati USB
  • Diametro 3.06 in
  • Potenza elettrica da 4 a 20 mA
  • Classificazioni della custodia NEMA Tipo 13
  • Altezza 4.9 in
  • Isolamento Poliuretano
  • Resistenza del circuito 400 Ω max
  • Materiali FKM, fluoroelastomero, policarbonato, polivinilidene, fluoruro
  • Isteresi media Selezionabile
  • Campo di misura, max 9.8 ft
  • Campo di misura, min 0 ft
  • Memoria Non volatile
  • Numero di fili 2
  • Pressione operativa, max 30 psi
  • Temperatura di esercizio, max 60 °C
  • Temperatura di esercizio minima -35 °C
  • Uscita segnale Corrente
  • Dimensioni attacco al processo 1 pollice
  • Tipo di attacco al processo NPT maschio
  • Temperatura di processo, max 60 °C
  • Temperatura di processo, min. -7 °C
  • Risoluzione 0,039 in
  • ID serie LVCN210-Series
  • Segnale di sicurezza 4 mA, 20 mA, 21 mA, 22 mA o mantieni l'ultimo valore
  • Inversione del segnale Da 4 a 20 mA o da 20 a 4 mA
  • Tensione di alimentazione 24 Vcc
  • Valore nominale dell'interruttore 60 VA, 1 A max
  • Tipo di interruttore SPST
  • Compensazione della temperatura Automatico

Supported Applications

The Omega LVCN210 Series is an ultrasonic level transmitter and controller designed for continuous measurement in small to medium tanks. As a non-contact sensor, it replaces float, conductance, and pressure sensors that may fail due to contact with dirty, sticking, or scaling media. The series supports general-purpose applications including day tank, skid, IBC, sump, machine, tool, and process tank level monitoring.

Operating Conditions & Performance

The LVCN210 Series provides a measurement range of 3 m (9.8') with an accuracy of ±0.2% of range and a resolution of 1 mm (0.039"). The sensor operates within a process temperature range of -7 to 60°C (20 to 140°F) and an ambient temperature range of -35 to 60°C (-31 to 140°F). It features automatic temperature compensation.

Performance specifications include a dead band of 10 cm (4") and a beam width of 5.08 cm (2"). The unit is rated for a Maximum Working Pressure (MWP) of 2 bar (30 psi). The enclosure carries a Type 6P rating, described as encapsulated, corrosion resistant, and submersible.

Configuration Options

The series offers configurable outputs, switching capabilities, and mounting options to accommodate specific installation needs. Key configuration parameters include:

  • Signal Output: 4 to 20 mA two-wire loop powered by 24 Vdc (loop). Signal invert is available as 4 to 20 mA or 20 to 4 mA.
  • Fail-Safe Logic: Configurable signal fail-safe options include 4 mA, 20 mA, 21 mA, 22 mA, or hold last. Contact fail-safe logic for power loss is set to Hold last; echo loss can be configured as Open, close, or hold last.
  • Relay Outputs: Four (4) SPST relays with a contact rating of 60 VA, 1A maximum. Hysteresis is selectable for the LVCN210 model.
  • Process Connection: Standard 1 NPT thread; optional 1" G thread available by adding "-G" to the model number.
  • Housing & Materials: Polycarbonate enclosure with a PVDF transducer. The mount gasket is FKM, and the cable jacket is Polyurethane (9-conductor, shielded).

The sensor includes non-volatile memory for configuration retention. Configuration is performed via free PC Windows® USB 2.0 software using an optional USB connector.

Key Product Differences

The LVCN210 Series distinguishes itself within the broader family by its specific range and output integration:

  • LVCN210: Includes a level transmitter with 4 to 20 mA signal, four relays, and an integrated USB connector for configuration.
  • LVCN210-B: Level transmitter with 4 to 20 mA signal and four relays; requires the separate LVCN414-USB accessory for software configuration.

The series is distinct from other family members (LVCN318, LVCN414) which offer different measurement ranges up to 5.5 m or alternative output signals such as voltage and frequency. The LVCN210 Series specifically targets the 3 m range with integrated relay control.

Accessories

installation hardware

Side Mount Bracket
C$97.72 / each
0 In Stock
2 G bracket
C$97.72 / each
0 In Stock
1 NPT SIDE MOUNT BRACKET
C$125.38 / each
0 In Stock
2 NPT X 1 NPT for Schedule 40
C$39.67 / each
0 In Stock
2 NPT X 1 NPT - SCH80
SGD116.10 / each
0 In Stock
3 NPT X 2 NPT for Schedule 40
/ each
0 In Stock
3 NPT X 2 NPT for Schedule 80
/ each
0 In Stock
Rated 4 out of 5 by from Useful I've used this in my college as a proof of concept. Love the easy to use system and plug and play setup.
Date published: 2017-04-10
Rated 1 out of 5 by from Not happy with this product We have 16 of this installed on 16 genset tanks, and we can get them to give an accurate reading when the units are not running, and we had to buy voltage regulators to stabilize the spikes we get from voltage reading.
Date published: 2019-04-02
Rated 2 out of 5 by from Quit Working We bought this item, installed it and it quit working the next day.
Date published: 2017-11-27
  • y_2026, m_10, d_5, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_LVCN210, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT

Is the LVCN210 suitable for use in a sewage lift station, i.e. intrinsically safe and material certified for use in a sewage environment?

Asked by: GrantL
Thank you for your inquiry. Unfortunately, this level controller does not have a rating for hazardous applications or ATEX approval.
Answered by: Applications Engineer JJC
Date published: 2024-01-24
  • y_2026, m_10, d_5, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_LVCN210, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 42ms
  • QUESTIONS, PRODUCT
en-CA
fr
Save Configuration