日本 +81 3 6822 0370 | 新しいウェブサイトへようこそ。問題やバグを見つけましたか?こちらからご報告ください
FL-10-Series
液体用可変面積流量計
- 化学的に不活性な濡れた部品
- 取り外し可能な保護シールド
- 個別にリークテスト済み
- 直接読み取りスケール
製品の概要
- 精度 ± 5 %
- 最大空気流量 0 m³/s
- 寸法に関する注意事項 低流量:長さ144 mm x 外径32 mm;高流量:長さ267 mm x 外径51 mm
- 真空下でのリーク率 10⁻⁷ cc He/s未満
- 材料 ポリプロピレン、PTFE、パーフルオロアルコキシ
- 材料、湿潤 PCTFE(ポリクロロトリフルオロエチレン), PTFE
- 対応媒体 プロセス水/冷却水
- 動作圧力(最大) 100 psi
- プロセス接続タイプ NPT メス
- プロセス温度(最高) 121 °C
- スケール ダイレクトリード
- スケール長の注記 0~10の目盛り
- シリーズID FL-10-Series
Supported Applications
The Omega FL-10 Series consists of variable area flow meters designed for liquid flow measurement. The series is engineered with chemically inert wetted components, making it suitable for high-purity applications and corrosive liquids.
Operating Conditions & Performance
Performance specifications are defined by the specific model range selected:
- Accuracy: ±5% of full scale
- Scales: 0 to 10 markings
- Maximum Temperature: 121°C (250°F)
- Maximum Pressure: 6.7 bar (100 psig)
- Leak Integrity: Individually leak tested and certified to a rating of 1 x 10-7 sccs of Helium
The series covers two primary flow envelopes: Low Flow models range from 125 mL/min to 5000 mL/min, while High Flow models cover 13 L/min to 45 L/min.
Configuration Options
The FL-10 Series is available in configurations with or without a standard valve for flow monitoring or control. Model numbers follow the pattern FL-10X-V (with valve) and FL-10X (no valve), where X denotes the specific range.
Materials of Construction
- Tube Shields: Polycarbonate
- Flow Tubes: PTFE, PFA
- Floats: PTFE
- Wetted Parts: PTFE end fittings, PCTFE guide rods
Process Connections & Dimensions
The series offers FNPT connections in sizes ranging from ¼ to ¾. Physical dimensions vary by flow capacity:
- Low Flow Models: 144 L x 32 mm OD (5¹¹⁄₁₆ x 1¼")
- High Flow Models: 267 L x 51 mm OD (10½ x 2")
Options & Accessories
The following options are available by adding suffixes to the model number for additional cost:
- Oxygen Cleaning: Add “-02CLEAN”
- NIST Calibration: Add “-NIST”
The series includes an operator's manual and features a removable protective shield. Units are factory-sealed in polyethylene bags to prevent contamination.
Key Product Differences
Variants within the FL-10 Series differ primarily by maximum flow capacity, connection size, and overall dimensions. Models with valve suffixes (e.g., -V) include a built-in needle valve at the outlet for control applications, while non-valve models are intended for monitoring only.
- Low Flow Range: Models FL-10A through FL-10J cover 125 mL/min to 5000 mL/max with ¼ or ⅜ FNPT connections.
- High Flow Range: Models FL-10K through FL-10P cover 13 L/min to 45 L/min with ½ or ¾ FNPT connections.
PDFとマニュアル
FL-10A10B10C10D10E10F10G10H10J10K10L10M10N10P-V