CL514-PLUS

Automated Universal RTD Calibrator

Choisir une variante

operating-temperature-max

$1,944.60 / each

Item# CL514-PLUS

Spécifications du produit

<< Voir tous les modèles de produit
Marque
Accuracy ± 0.025 %
Accuracy Detail ± (0.025% of reading + 0.05 Ω)
Additional Features 1 Read & Source Signals
Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
Battery life 50 hr
Display Type LCD
Display Type Note High contrast graphic liquid crystal display, LED backlighting for use in low lit areas
GrossWeightValue 1.56
Height 40.64 mm
Length 143 mm
Operating Temperature Note Nominal Temperature: 23°C
Operating Temperature, Max 60 °C
Operating Temperature, Min -25 °C
Protection Over-voltage protection to 60 V dc (rated for 30 seconds) (Protection against misconnection)
Relative Humidity Note 10% ≤RH ≤90% (0 to 35°C), non-condensing 10% ≤RH≤ 70% (35 to 60°C), non-condensing, Nominal Relative Humidity: 70%
Relative Humidity, Max 0.9
Relative Humidity, Min 10%
Series ID CL514-PLUS-series
Supply Voltage 1.5 Vdc
Temperature Drift ± 0.01%
Temperature Drift Note ± 0.01% of span outside of 23°C ± 10°C (73°C ± 18°F
Thermocouple Type N/A
Type of RTD Signal 100 Ω, 1000 Ω
Voltage Read Excitation Current: 0.5 mA nominal Normal Mode Rejection: 50/60 Hz, 50 dB Common Mode Rejection: 50/60 Hz, 120 dB
Voltage Source Accuracy From 1 to 10.2 mA External Excitation Current: ± (0.025% of Reading + 0.05 Ω) Below 1 mA of External Excitation Current: ± (0.025% of Reading + 0.025 mV/ mA Excitation Current + 0.05 Ω) Resistance Ranges: 0.00 to 410.00, 410.1 to 2001.0 Ω Allowable Excitation Current Range: <410 Ω: 10.2 mA max; steady or pulsed/intermittent 410 to 2001 Ω: 1 mA max; steady or pulsed/intermittent Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width
Weight 12.1 oz
Weight Note 12.1 oz (including boot and batteries)
Width 76.2 mm
operating-temperature-max 60 °C
Pays d'origine United States
Voir toutes les spécifications Montrer moins
Automated Universal RTD Calibrator CL514-PLUS CL514-PLUS
Rated 4 out of 5 by from Great Product Great device, fast shipping. Does exactly as described. Do note that the Sourcing capabilities have a current limit that prevented us from working with some of our devices.
Date published: 2026-06-01
  • y_2026, m_11, d_15, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.50
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_CL514-PLUS, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
en