Skip to search Skip to main content Skip to navigation

Taiwan 0809 090 375 | Intl +65 6415 5353 | Welcome to our new site - found a bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-I2-1

Immersion Temp Probes for Water Monitoring with Stainless Steel Thermowells

  • Direct wall mounting
  • 6´cable
  • 1/2" internal NPT accepts conduit for more industrial installation
Series-I2-1
From TWD 1,035
Immersion Temp Probes for Water Monitoring with Stainless Steel Thermowells Series-I2-1 Series-I2-1
loading all models
Product Overview
  • Cable Length 6 ft
  • Mounting Orientation 1/2 in Threaded Connection to Fit Series IW2 Thermowell
  • Operating Temperature, Max 240 °F
  • Operating Temperature, Min -32 °F
  • Probe Diameter 0.25 in
  • Series ID Series-I2-1
  • Sheath Material 304 Stainless Steel

Supported Applications

The Dwyer Series I2-1 Immersion Temperature Probes are designed to monitor hot and chilled water lines throughout a building's water distribution loop. These sensors feature multiple temperature sensor outputs that allow connection to virtually any digital building controller.

A critical operational requirement is the use of a Series IW2 Thermowell on pressurized air and water lines to prevent leakage around the probe. The thermowells enable replacement of the temperature sensors without draining the water line.

Operating Conditions & Performance

The series operates within a process temperature range of -32 to 240°F (-35.5 to 115.5°C). Accuracy specifications vary by sensor element type:

  • Platinum RTD: ±0.6% @ 32°F (0°C)
  • Nickel RTD: ±0.5°F @ 32°F (0°C)
  • Balco RTD: ±0.1% @ 32°F (0°C)
  • Thermistors: ±0.36°F from 32 to 158°F (0 to 70°C)

Configuration Options

The Series I2-1 offers a broad selection of sensor technologies and insertion lengths configured for specific controller interfaces.

Sensor Types & Outputs

Available output signals include RTD and Thermistor elements. Specific model configurations support:

  • Pt 100 Ω RTD (e.g., I2-11062, I2-11042)
  • PT 1000 Ω RTD
  • Ni 1000 Ω RTD
  • Balco 1000 Ω RTD
  • Thermistors: 3K Ω, 5K Ω, 10K Ω Type 2, 10K Ω Type 3, 20K Ω, 100K Ω, and 2252 Ω

Dimensions & Construction

The probes feature a 1/4" (6.3 mm) diameter with insertion lengths of 4" or 6". Overall length is L = 7.000" for the 6" thermowell and L = 5.000" for the 4" thermowell. The process connection utilizes a 1/2" threaded interface to fit Series IW2 thermowells.

Materials

  • Sheath Material: 304 SS
  • Thermowell Material (Series IW2): 304 SS

Key Product Differences

Variants within the series are distinguished by sensor element type and insertion length. The model number guide follows the format I2-<SENSOR_TYPE>-<INSERTION_LENGTH>. For example, models ending in 62 indicate a 6" insertion length (e.g., I2-15062), while those ending in 42 indicate a 4" insertion length (e.g., I2-15042). The Series IW2 thermowells are available as separate components, such as the IW2-262 for 6" and IW2-242 for 4" applications.

Accessories

accessories

IW2-242 4" SS THERMOWELL
TWD1,430 / each
0 In Stock
IW2-262 6" SS THERMOWELL
TWD1,372 / each
0 In Stock
en-TW
en_TW
Save Configuration