Brand
Accuracy ± 2 %
Additional Features 1 Dual Channel; NEMA 4X (IP65) front and back with optional NEMA 4X (IP65) rear cover kit
Conductivity Measurement 0.055 to 400,000 µS/cm
Display Type 2 x 16 Alphanumeric LCD
Display Type Note Alphanumeric 2 x 16 LCD Contrast: User selected, 5 levels Update rate: 1.5 seconds
Enclosure Ratings IP65, NEMA Type 4X
Frequency 50/60 Hz
Materials PBT, Polycarbonate
Number of Relays None
Operating Range Note Resistivity: 10 kΩ/cm to 18.26 MΩ/cm (0.055 to 100 μS/cm); TDS: 0.001 to 999999 ppm or ppb (display limit)
Operating Temperature, Max 120 °C
Operating Temperature, Min -25 °C
Output Detail Current Outputs: (3 each) 4 to 20 mA, isolated, fully adjustable and reversible Max Loop Impedance: 150 Ω @ 12V, 450 Ω @ 18V, 750 Ω @ 24V Update Rate: Approx. 100 mS Accuracy: ±0.03 mA @ 25°C, 24 Vdc Open Collector Outputs: (2 each) Isolated, 50 mA sink or source, 30 Vdc max pull-up voltage Operational Settings: Hi, Lo, USP, Pulse, Off Hysteresis: User adjustable Time Delay: 0 to 6400 seconds Maximum Pulse Rate: 400 pulses/minute
Power Consumption 20 VA
Relay Note (up to 4 each) SPDT Relays Maximum Voltage Ratings: 5A @ 30 Vdc or 5A @ 250 Vac Operational Settings: Hi, Lo, USP, Pulse, Off Hysteresis: User adjustable Time Delay: 0 to 6400 seconds Maximum Pulse Rate: 400 pulses/minute
Resistivity Measurement Range 10 kΩ/cm to 18.26 MΩ/cm
Series ID CDCN91-Controller
Temperature Accuracy ± 0.5 °C
Weight 581 g
See All Specs Show Less
Dual Channel Conductivity/ResistivityController CDCN91-Controller CDCN91-Controller

Accessories

consumables

1500 µS/cm conductivity solution
TWD798 / each
37 In Stock
450 µS/cm conductivity solution
TWD798 / each
49 In Stock
4500 µS/cm conductivity solution
TWD879 / each
70 In Stock

installation hardware

TRANSMITTER COVER NEMA 4X
/ each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.

sensors

Conductivity Cells
TWD19,326 / each
8 In Stock
Conductivity Cells
TWD20,148 / each
8 In Stock
Conductivity Cells
/ each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
en-TW
en_TW
Save Configuration