Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | International +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Series-Mark

Item# Series-Mark

In Stock

Lead Time (If not in stock): 0 week

Product Specs

<< See all Product Models
Brand
Altitude,Max 2000 m
Electrical Connection 3/4 in NPT female Conduit with Screw Terminal block
Electrical Connection Note Screw terminal. Optional factory sealed leads that are 36˝ (914.4 mm) of 16 AWG, Conduit Connection: Standard: one 3/4˝ female NPT; optional one to two 1/2˝ female NPT; WirelessHART® models: two 1/2˝ female NPT; Optional: M25 X 1.5 or M20 X 1.5 connections may be supplied in lieu of 3/4˝ and 1/2˝ female NPT for all models.
Enclosure Ratings Hazardous Location Rated, NEMA Type 1, NEMA Type 12, NEMA Type 13, NEMA Type 2, NEMA Type 3, NEMA Type 3R, NEMA Type 3s, NEMA Type 4, NEMA Type 4X, NEMA Type 6, NEMA Type 7, NEMA Type 9
Enclosure Ratings Note Product Ratings: Weatherproof and flameproof. NEMA 1, 2, 3, 3R, 3S, 4, 4X, 6, 7, 9, 12, 13. UL rated: class I, div. 1 and 2, groups B, C, D (some units available for group A, consult factory); class II, div. 1 and 2, groups E, F, and G. CSA rated: class I, div. 1 and 2, groups A, B, C, D; class II, div.1 and 2, groups E, F, and G. Submersible to 15 meters (IP68);It is up to the end user to source the proper fittings to ensure a watertight seal. ATEX Compliant: -B suffix, directive 2014/34/EU, KEMA 03ATEX2391 X, 2813 II 2G Ex db IIC T6 Gb for -25°C/-40°C/-50°C ≤ Tamb ≤ 63°C and T5 for -25°C/-40°C/-50°C ≤ Tamb ≤ 63°C, optional wording depending on output and switch type selected. Compliant per EN 60079-0, EN 60079-1.-IS suffix, directive 2014/34/EU, KEMA 03ATEX1392 X, 2813 II 1G Ex ia IIC T4 Ga. Compliant per EN EN 60079-0, EN 60079-11. IECEx Compliant: -IE suffix, IECEx DEK 11.0056X Ex db IIC T6 Gb for -25°C/-40°C/-50°C ≤ Tamb ≤ 63°C and T5 for -25°C/-40°C/-50°C ≤ Tamb ≤ 63°C, optional wording depending on output and switch type selected. Compliant per IEC 60079-0,IEC 60079-1. -II suffix, IECEx DEK 11.0061X Ex ia IIC T4 Ga. Compliant per IEC 60079-0, IEC 60079-11, IEC 60079-26. UKEX Compliant: -BX suffix: DEKRA 21UKEX0274X, Ex db IIC T6 Gb for -25°C/-40°C/-50°C ≤ Tamb ≤ 63°C depending on output and switch type selected. Compliant per EN 60079-0 and EN 60079-1. -ISX suffix: DEKRA 21UKEX0333X, Ex ia IIC T4 Ga, compliant per EN 60079-0 and EN 60079-11.
Mounting Orientation Not Position Sensitive
Operating Temperature, Max 176 °F
Operating Temperature, Min -58 °F
Operational Life Over 10,000,000 Cycles
Series ID Series-Mark
Set Point Adjustment 5 to 360°
Switch Note 15 A @ 125/250/480 VAC (~) ; 1/8 hp @ 125 VAC (~), 1/4 hp @ 250 VAC (~), 1/2 A @ 125 VDC, 1/4 A @ 250 VDC
Weight 6 lb
See All Specs Show Less
Weatherproof Position Indicators for Rotary/Linear Valves & Actuators Series-Mark Series-Mark

Accessories

accessories

1 pt bottle of red gage fluid, .826 sp. gr.
€ 51,93 / each
0 In Stock
Clear flexible vinyl tubing, 3/16" ID x 5/16" OD, lengths to 500'; 45 psi maximum pressure @ 73°F.
€ 0,83 / foot
0 In Stock
en-NL
en_NL
Save Configuration