Australia +61-2-4272 2055 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-PULSE101A-Logger
Pulse Input Data Logger
Models In Stock
- 10 Year Battery Life
- 10 KHz Pulse Rate
- Multiple Start/Stop Function
- Ultra High Speed Download
OM-CP-PULSE101A-Logger
From
$
155.24
Models In Stock
Product Overview
- Accuracy ± 1 min/month
- Accuracy Detail ±1 minute/month at 20°C, stand alone data logging
- Battery life up to 10 yr
- Battery Size and Type 3.6V Li-ion
- Baud Rate 115200
- Data Interface USB
- Display Measuring Units °C, °F, ft/min, k/h, kts, m/s, mph
- Electrical Connection Removable Screw Terminal
- Height 2.5 in
- Impedance Input >60 kΩ
- Internal Weak Pull-Up <60 μA
- LED Indicators Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
- Length 0.6 in
- Materials ABS, Aluminum
- Memory 500,000 readings; software configurable memory wrap 250,000 readings in multiple start/stop mode
- Memory Modes Yes
- Multi Start/Stop Mode Note To start the device press and hold the pushbutton for 5 seconds, the device has started logging; to stop the device press and hold the pushbutton for 5 seconds while the device is logging, the device has stopped logging
- Number of Measurements 1
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -40 °C
- Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
- Pulse Rates 10 kHz
- Pulse Width, Min ≥ 10 µsec
- Real Time Recording The device may be used with PC to monitor and record data in real-time
- Relative Humidity 0 to 95% RH non-condensing
- Samples,Max 1 sec
- Sampling Rate 1 Hz (1 update/second)
- Series ID OM-CP-PULSE101A-Logger
- Software XP SP3/Vista/7 and 8 (32 and 64-bit)
- Start Modes Delayed Start, Immediate Start, Push-button
- Supply Power Type Battery
- Voltage Input Range 0 to 30 vdc
- Weight 0.9 oz
- Width 1.4 in
Supported Applications
The Omega OM-CP-PULSE101A is a pulse input data logger designed to sense and record pulses or contact closures from external sources. Documented applications include monitoring gas, water, and electric meters via transducers or pulse initiators. The device transforms these inputs into engineering units, allowing users to store user-defined units such as gallons/min or scale outputs for flow rate and wind speed.
Operating Conditions & Performance
The OM-CP-PULSE101A operates within an ambient temperature range of -40 to 80°C (-40 to 176°F) and a humidity rating of 0 to 95% RH non-condensing. It accepts pulse inputs in the continuous voltage range of 0 to 30 Vdc with a maximum frequency of 0 to 10 KHz. The device features an accuracy of ±1 minute/month at 20°C (68°F) and includes a real-time clock for time-stamping data.
Memory capacity supports up to 500,000 readings. Data recording intervals are selectable from 1 second to 24 hours in adjacent 'time bin' periods. The unit is powered by an included user-replaceable 3.6V lithium battery with a typical life of 10 years, dependent upon frequency and duty cycle.
Configuration Options
The series offers configurable options for connectivity, environmental protection, and maintenance:
- Housing & Enclosure: The data logger features an ABS plastic housing. An optional weatherproof NEMA 4 (IP65) enclosure (OM-CP-WATERBOX101A), constructed from black anodized aluminum, is available for outdoor or harsh environments.
- Data Interface & Software: Data download and configuration require a USB interface cable. The OM-CP-IFC200 accessory includes Windows software and a 3.7 m (12') USB interface cable necessary to operate the logger.
- Pow er Supply Options: A replacement 3.6V lithium battery is available as part number OM-CP-BAT105.
- Maintenance Kits: The OM-CP-WATERBOX101A-KIT provides a maintenance kit for the weatherproof enclosure.
The device includes an electrical connection via removable screw terminals. Optional password protection restricts access to configuration options, though data can be read out without the password status indicator LEDs provide visual feedback: Green LED blinks at 10-second rate (logging) or 15-second rate (delay start); Red LED indicates low battery/full memory (10-second blink) or alarm condition (1-second blink).
Key Product Differences
The OM-CP-PULSE101A is the primary model in this series, defined as a pulse input data logger with USB interface. The product line includes specific accessory models to support installation and operation:
- OM-CP-PULSE101A: Pulse input data logger.
- OM-CP-IFC200: Windows software and USB interface cable (required for operation).
- OM-CP-BAT105: Replacement battery.
- OM-CP-WATERBOX101A: Weatherproof enclosure.
The data logger dimensions are 64 L x 36 W x 16 mm D (2.5 x 1.4 x 0.6") with a weight of 24 g (0.9 oz). The optional waterbox enclosure measures 74 H x 148 W x 39 mm D (2.9 x 5.8 x 1.5").
PDFs & Manuals
Software & Drivers