Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OS-TX-USB-Series

Modbus IR Transmitter with 4-20 mA and USB outputs

  • IR Transmitter with MODBUS over USB for use with other software or devices
  • PC configuration, real-time display, charting and CSV text file logging via free software
  • Features Max, Min, Average and Instantaneous Readings Peak or Valley Hold Reflected Energy Compensation
  • Stainless Steel Housing, Sealed to IP65
OS-TX-USB-Series
From C$ 1,070.70
Modbus IR Transmitter with 4-20 mA and USB outputs OS-TX-USB-Series OS-TX-USB-Series
loading all models
Product Overview
  • Cable Length 1 m
  • Data Interface USB
  • Data Interface Note USB 2.0 (removable USB cable and software included) using the Modbus protocol
  • Display No
  • Emissivity, Max 1
  • Emissivity, Min 0.1
  • Enclosure Ratings IP65
  • Housing Material Stainless Steel
  • Impedance 900 Ω
  • Intrisically Safe No
  • Laser Output false
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min 0 °C
  • Relative Humidity Note 95% max. non-condensing
  • Repeatability ± 0.5°C
  • Repeatability Note ± 0.5°C or 0.5% of readi ng, whichever is greater
  • Response Time 200 ms
  • Sensing head Mounting 20 mm
  • Sensor Voltage 6 Vdc
  • Series ID OS-TX-USB-Series
  • Span, Max Full temperture Range
  • Span, Min 100 °C
  • Supply Voltage 24 to 28 Vdc
  • USB Cable Length 1.8 m
  • Weight 155 g

Supported Applications

The Omega OS-TX-USB-Series consists of fixed infrared (IR) temperature transmitters designed for non-contact surface temperature measurement. The series offers two primary spectral response configurations to address different material emissivities: general-purpose models with an 8 to 14 µm wavelength and short-wavelength models at 2.2 µm.

General-purpose (USB suffix, 8-14 µm) sensors are suitable for high-emissivity materials including paper, thick plastics, food, pharmaceuticals, rubber, asphalt, and painted surfaces. These models support sub-zero measurements applicable to the food, logistics, and storage industries. Short-wavelength (2USB suffix, 2.2 µm) sensors provide accurate readings on low-emissivity reflective metals and high-temperature targets. Additionally, short-wavelength models are capable of measuring through glass viewports.

Operating Conditions & Performance

The series operates within an ambient temperature range of 0°C to 70°C; air/water cooled housing options (WC) are available for higher temperatures. The enclosure carries an IP65 rating and functions in relative humidity up to 95% max. non-condensing.

Measurement ranges vary by model configuration:

  • -40°C to 1000°C: Available on all models (general-purpose).
  • 45°C to 300°C: LT range, available for OS151A-2USB-LT only.
  • 250°C to 1000°C: MT range.
  • 450°C to 2000°C: HT range.

Accuracy is specified as ± 2°C or 1% of reading, whichever is greater for short-wavelength models (2.2 µm), and ± 1°C or 1% of reading, whichever is greater for general-purpose models (8-14 µm). Repeatability is listed at ± 0.5°C or 0.5% of reading, whichever is greater. The response time is 200 ms.

Electrical Specifications

The transmitters require a power supply of 24 V DC (maximum 28 V DC) with a minimum sensor voltage of 6 V DC. Maximum loop impedance for the analog output is 900 Ω @ 24 V DC.

Configuration Options

The OS-TX-USB-Series provides dual outputs: a linear, 2-wire 4 to 20 mA signal compatible with indicators, controllers, recorders, or data loggers, and USB 2.0 communications using the Modbus protocol (removable cable included). Emissivity is configurable from 0.1 to 1.0.

Configuration options include:

  • Spectral Response: General-purpose (8-14 µm) or short-wavelength (2.2 µm).
  • Optics: Divergent optics ratios of 15:1, 25:1, 30:1, and 75:1; close-focus optics with focal spot sizes of 5 mm at 100mm distance or 7.5 mm at 500mm distance.
  • Temperature Ranges: LT (45°C to 300°C), MT (250°C to 1000°C), HT (450°C to 2000°C), and standard (-40°C to 1000°C).
  • Cooling: Standard sensor without cooling or air/water cooled jacket with air purge collar.
  • Mounting & Accessories: Fixed mounting bracket, adjustable mounting bracket, laser sighting tool (OSUSB-LST), and extended 4-20 mA output cables up to 30 m maximum length.

The housing is constructed of stainless steel with overall dimensions of Ø 27.6 x length 61 mm including cable glands. The process connection is M20 x 1 mm pitch, length 15 mm. Standard output cable length is 1 m; USB cable length is 1.8 m.

Key Product Differences

The series distinguishes between general-purpose and short-wavelength models via the spectral response code in the model number (USB vs. 2USB). General-purpose models cover -40°C to 1000°C, while short-wavelength models offer selectable ranges from 45°C to 300°C up to 450°C to 2000°C.

Optics codes define the target spot size and distance capabilities: 151A (15:1 divergent), 251A (25:1 divergent), 751A (75:1 divergent), 301A (30:1 divergent), and 801A (close-focus). The LT temperature range is restricted to the OS151A-2USB-LT model. Cooling options are indicated by a blank code for standard sensors or WC for air/water cooled jackets with an air purge collar.

Accessories

accessories

The air purge collar is used to keep dust, fumes, moisture and other contaminants away from the lens. Air flows into the fitting on the side and out of the aperture at the front.
C$188.50 / each
0 In Stock
L’outil de visée laser montre précisément où le capteur est dirigé. Une fois centré sur la cible, l’outil de visée laser peut être retiré.
C$747.39 / each
0 In Stock

installation hardware

Le support de montage fixe en forme de L offre un support rigide pour le capteur et permet un réglage fin de la rotation autour d’un axe.
C$36.25 / each
0 In Stock
Adjustable bracket for IR-USB
$66.00 / each
5 In Stock
Rated 5 out of 5 by from Perfect for what it was purchased for. Does exactly what we needed it to, will purchase again.
Date published: 2024-11-05
  • y_2026, m_11, d_15, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.50
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_OS151A-2USB-LT, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT

Can this unit be calibrated?

Asked by: Jen1
It does not appear to have been calibrated in the past but send a follow up to temp@dwyeromega.com and it can be reviewed.
Answered by: ApplicationEngineerANB
Date published: 2024-06-07
  • y_2026, m_11, d_15, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.50
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_OS151A-2USB-LT, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
OS151A251A301A751A801A-2USB-USB-LT-MT-HT
Optics
USB Output Version
Temperature Range
en-CA
en_CA
Save Configuration