TX13-Smart-Temp-Tx

Emetteurs thermocouple en-tête

Modèles en stock
  • Entrées thermocouple K, J, N, E, T, R, S et mV
  • Configuration via touches
  • 56 plages préprogrammées prêts-à-utiliser
  • Fonction Trim - annuler erreur de capteur
  • Usure programmable avec indicateur de panne du capteur
  • Isolation galvanique
TX13-Smart-Temp-Tx
À partir de C$ 219.71
Modèles en stock
Emetteurs thermocouple en-tête TX13-Smart-Temp-Tx TX13-Smart-Temp-Tx
loading all models
Aperçu du produit
  • Précision ± 5 µA
  • Précision (sortie mA/2000) ou 5 µA (le plus élevé des deux)
  • Homologations BS EN 61326 ; 1998 – Équipements électriques pour la mesure et le contrôle ANNEXE A ; ANNEXE F
  • Étalonnage Bouton-poussoir
  • Compensation de jonction froide ±0,05°C/°C
  • Précision de la température de la jonction froide ±0,5 °C
  • Diamètre 43 mm
  • Connexion électrique Borne à vis
  • Puissance électrique 4 à 20 mA
  • Hauteur 21 mm
  • Échelle d'humidité 10 à 90 % HR sans condensation
  • Précision d'entrée ± 0,5 °C
  • Température de fonctionnement, max 85 °C
  • Température de fonctionnement, min -40 °C
  • Charge de sortie [(Vsupply-10)/20] kΩ
  • Longueur de la sonde 0 mm
  • Fonctions programmables décalage, Échelle, Indication de brûlure du capteur, Type de capteur
  • Temps de réponse 1 s
  • Effet d'auto-échauffement 0,2 uA/V
  • Type du capteur Transmetteur
  • ID de série TX13-Smart-Temp-Tx
  • Commandes de configuration Bouton-poussoir, la LED de programmation clignotera par rafales
  • Matériau de la gaine N/A
  • Stabilité Offset : 0,1°C/°C ; Plage : 0,05°C/°C
  • Temps de démarrage I out < 4 mA pendant le démarrage
  • Température de stockage, max 90 °C
  • Température de stockage, min -50 °C
  • Type d'approvisionnement électrique CC
  • Tension d'alimentation 10 à 30 Vcc
  • Échelle d'entrée de température K : -200 à 1370 °C ; J : -100 à 1200 °C ; E : -100 à 1000 °C ; N : -180 à 1300 °C ; T : -100 à 400 °C ; R -10 à 1760 °C ; S : -10 à 1760 °C
  • Effets thermiques 1 uA/°C
  • Fréquence de mise à jour, max 500 ms
  • Temps de chauffe 1 min pour une précision complète
  • Poids 31 g
Le transmetteur de thermocouple à montage intégré TX13 convertit une entrée de thermocouple sur une plage configurée en un signal de transmission industriel standard (4 à 20 mA). Un fonctionnement simple permet à l'utilisateur de sélectionner le type de thermocouple, le sens de brûlage, de sélectionner des échelles fixes et de régler les points 4 et 20 mA. Le transmetteur intégré à la tête intègre les dernières technologies numériques pour garantir des performances précises et sans dérive.
Le calibrage d'usine par défaut est pour une échelle de 0 à 1000 °C et une entrée de thermocouple de type K, avec brûlure à l'échelle supérieure. 

Accessoires

cables

Câbles blindés à 2 conducteurs, 30 m (100 pi)
C$86.07 / each
2 En stock
Rated 5 out of 5 by from Great buy Excellent device for tight applications. I put it inside a 3" junction box and fit perfectly.
Date published: 2016-02-15
Rated 3 out of 5 by from Beginner I like the transmitter that you guys have, as it's very versatile. I am new to the field and I'm teaching myself setup and calibration. I thought that it would have been nice to know that I would have to expect to do that in advance and with more direction. The device certainly needed trimmed to the (-100C / 100C) range of the T type thermocouple. I thought that it would be a lot closer to the 4mA & 20mA output than it was. I had to buy a calibrator and learned how to operate the new machine and was able to trim that device to exactly (-100C / 100C) to 4mA & 20mA, and that was fun, and the device was easy to configure. It was so far off though it surprised me, it seems the true zero and span for the T type was actually set to something other than (-100C / 100C) so it's not plug and play, and maybe they never are. I'm a beginner, and now maybe a novice! What I've learned I will be able to apply to many things in our facility and I certainly like the easy configuration that your product offers, now that I know how it all works. The Best School is the School of Hard Knocks!
Date published: 2016-03-18
Rated 5 out of 5 by from TX13 Easy Integration. No problems calibrating the sensor either
Date published: 2025-01-29
Rated 5 out of 5 by from Smart Temperature Transmitters Review Came in very timely manner, Will be used in a chemical environment
Date published: 2024-06-10
  • y_2026, m_5, d_11, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_TX13, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

What is the country of origin for your TX13 transmitters?

Asked by: judib63
Thank you for the inquiry. TX13 origin is Great Britain. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-03-27

Could you please share reliability data (FIT/MTBF) for the TX13-TX-SCALED? Thank you

Asked by: RM2021
Hi RM2021, Thank you for the inquiry. Unfortunately we do not offer requested data on the requested product. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-10-27

To use with Omega SA2C-K, type K TC with -50 to 200C range: -50 to to 200 is not one of the preconfigured ranges for TX13. What is the PN to order if we want the transmitter come with -50 to 200 reconfiguration?

Asked by: emali53
Thank you for the inquiry. You can add factory configuration option to a new TX13 with part# TX13-TX-SCALED. When placing order add scaling detail to description on PO copy. Else, if placing order via web site, add scaling details to Special Instructions box in line item details in shopping cart. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-08-13

Can you use any type of TC on this TX? ex. J or T if it only states K on the device?

Asked by: NCJOe
Thank you for your inquiry NCJOe. TX13 is compatible with K, J, N, E, T, R, S Thermocouples.
Answered by: Application Engineer SP
Date published: 2022-08-10
  • y_2026, m_5, d_11, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_TX13, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration