Passer à la recherche Passer au contenu principal Passer à la navigation

Besoin d'aide? Appelez-nous: 1-800-663-4209

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

FLD-Nitrogen-Series

Compteurs de débit à zone variable à lecture directe, montés sur panneau pour l'azote

Modèles en stock
  • Panel-mount variable area flow meter calibrated specifically for nitrogen flow
  • Precision ±5% FS accuracy with 10:1 turn-down ratio for flexible monitoring
  • Wetted parts in 316 SS or aluminum, compatible with pure gas systems
  • Rated for up to 200 psi process pressure and industrial use temperature range
FLD-Nitrogen-Series
À partir de C$ 527.36
Modèles en stock
Compteurs de débit à zone variable à lecture directe, montés sur panneau pour l'azote FLD Nitrogen-Series FLD Nitrogen-Series
loading all models
Aperçu du produit
  • Précision ± 5 %
  • Plaque arrière Acryliques blancs de 1/8" d'épaisseur
  • Type de flotteur Carboloy
  • Compatibilité avec les fluides Gaz inertes / non réactifs
  • Montage Montage sur panneau
  • Raccords de montage en contact avec les fluides Acier inoxydable 316, Aluminium, Anodisé noir
  • Nombre de tubes 1
  • Pression de Fonctionnement, max 200 psi
  • Taille du raccordement au process 1/8 po
  • Type de raccordement au process NPT femelle
  • Température maximale du processus 121 °C
  • Répétabilité ± 0,25 %
  • Échelle Lecture directe
  • ID de série FLD Nitrogen-Series
  • Rapport de réduction 10:1
  • Type de valve No Valve

Supported Applications

The Omega FLD Series comprises direct read variable area flow meters (rotameters) calibrated for specific gases and liquids. The series is designed for metering carrier gases in chromatography, indicating and controlling gases in manufacturing processes, liquid and gas measurement in laboratories and pilot plants, as well as general flow and level indication.

While the broader FLD family supports Air, Water, Argon, Carbon Dioxide, Helium, Hydrogen, Oxygen, and Nitrogen, this specific series is calibrated for Nitrogen (N2). The instruments feature rib-guided or fluted metering tubes to ensure stable readings.

Operating Conditions & Performance

The FLD Series operates within defined pressure and temperature limits suitable for laboratory and process environments. Key performance specifications include:

  • Accuracy: Standard accuracy is plus/minus 5% of full scale (FS).
  • Repeatability: Plus/minus 0.25%.
  • Useful Flow Range: Minimum 10:1; the minimum flow rate is 10% of the maximum rate shown for a specific model.
  • Maximum Operating Pressure: 200 psig/13.8 bars.
  • Maximum Operating Temperature: 121 C (250 F).

Note that NIST traceable calibration is not available for this series.

Configuration Options

The Nitrogen-calibrated models are offered in two tube lengths, 65 mm and 150 mm, with a variety of float materials to accommodate different flow ranges. The series supports the following configuration options:

Housing and Mounting

  • Frames: Aluminum (black anodized) or 316 stainless steel.
  • Mounting Style: Standard panel mount with two retaining nuts supplied; convertible to bench mounting using optional FLTR-1, FLTR-2, or FLTR-3 acrylic tripods with built-in spirit levelers and leveling screws.
  • Dimensions (Panel Mount): Drill two 15 mm (0.59 in) holes; maximum panel thickness is 9.5 mm (0.375 in).

Sensor Elements and Wetted Materials

  • Floats: Available materials include glass, red sapphire, 316 stainless steel, carboloy, and tantalum.
  • Flow Tubes: Heavy walled borosilicate glass with interchangeable tubes for easy exchange.
  • O-Rings/Packing: Buna O-rings in aluminum/brass models; FKM O-rings in stainless steel meters. Optional perfluoroelastomer and EPR are available.

Valves and Connections

  • Process Connection: 1/8 NPT female inlet and outlet connections.
  • Standard Valve: Built-in 6-turn needle valve (inlet mounted standard).
  • Valve Options: -NV suffix for units without a valve; -HRV suffix for a 16 turn high resolution non-rising stem metering valve on 150 mm meters.
  • Orientation Notes: For liquids, valves may be at inlets or outlets (top); for vacuum services, valves must be mounted at outlets. If unspecified, units ship with valves at the inlet.

Special Service Options

  • -02CLEAN: Oxygen cleaning option available.

Key Product Differences

The FLD Nitrogen-Series is distinguished by its specific calibration for N2 and the availability of different frame materials. Models are grouped in ordering tables by tube length (65 mm or 150 mm) and fluid type.

  • Float Suffixes: Model numbers indicate float material via suffix: G for glass, ST for 316SS, C for carboloy, and SA for red sapphire.
  • Nitrogen Ranges (65 mm): Models such as FLDN3301ST through FLDN3306S cover ranges including 12 L/min down to 6 mL/min and up to 200 mL/min, utilizing a 316 SS frame.
  • Nitrogen Ranges (150 mm): Models such as FLDN3501ST through FLDN3506S cover ranges including 1.6 scfm down to 2 L/min and up to 500 mL/min, also utilizing a 316 SS frame.
  • No-Valve Variants: Specific SKUs (e.g., FLDN3504C-NV) are available with the -NV suffix for applications requiring no valve assembly.
Rated 5 out of 5 by from I got Flow Control... Omega always has a great selection of products & technical data so you can find what you need...and this was no exception. The right flow range for the job.
Date published: 2018-12-12
Rated 5 out of 5 by from Quality Product Meets our needs as expected. Quality product and excellent delivery.
Date published: 2025-02-10
Rated 5 out of 5 by from Rotameter Flow Meter Dwyer Omega FLDN3505C Is a good product it flow meter Rotameter from Dwyer Omega
Date published: 2025-02-03
Rated 5 out of 5 by from Direct Read Flow Meter Great flow meter and you cant beat the price. I have bought several of these over the years and they always perform well.
Date published: 2024-10-21
Rated 5 out of 5 by from Wonderful product Wonderful product with exact presision, also has an excellent duration
Date published: 2024-05-31
Rated 5 out of 5 by from Hydrogen Flowmeter Thank you Omega for custom suppling me the Hydrogen Flow meter, which is not available on the market, in a very short time , even beating the estimated time, one again I can't thank you enough. Kevork
Date published: 2024-04-30
Rated 5 out of 5 by from Flow Meter Great product for measuring liquid or gas. Comes in handy.
Date published: 2024-04-15
  • y_2026, m_8, d_8, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_CA, sid_FLDN3301ST, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

For the product FLDN3305G, the readings are in STANDARD LPM?

Asked by: PE1234
Thank you for your inquiry. The FLDN3305G has a range of up to 120mL/min. The units on the scale will be in mL/min.
Answered by: AS Engineer
Date published: 2020-04-29

Where do I reed the ball on the FLDA3214G-NV flow meter. The top or the center?

Asked by: Dgo1
Thank you for your inquiry about the rotameters. The Rule of Thumb is to read the flow rate at the highest and widest part of the float and in this case, a sphere will be the center.
Answered by: Application Engineer JC
Date published: 2023-08-15

Hi. Can I assume that all FLD series meters are volumetric, or is there an option to order them so that they are standardized?

Asked by: Bria
Thank you for your inquiry. They are calibrated at standard conditions, yet, no options for a calibration certificate.
Answered by: Applications Engineer JJC
Date published: 2024-10-07

Ordered an FLDA3420C-NV rotameter. Per spec sheet it has a max flow of 10 L/min. But now see the website says the units are SCFM and the readings on the meter go to 10. Which is the correct measurement unit?

Asked by: Remote Alaska
Thanks for your question? The part number, FLDA3420C-NV, rota-meter with no valve has been confirmed to have a max flow capacity of 10 LPM.
Answered by: application engineer je
Date published: 2019-07-15

Is the connection 1/8 pipe size? or 1/8'' Outer Diameter?

Asked by: Wfreer
Thank you for your inquiry. The process connection is 1/8 inch NPT
Answered by: Applications Engineer JJC
Date published: 2024-11-20

Is there an option available that can be sanitized in place using peroxyacetic acid?

Asked by: Richy
Thank you for your inquiry. If you would like to use the acid in question to clean, please consult a Chemical compatibility handbook to determine if the wetted materials are chemically compatible.
Answered by: Applications Engineer JJC
Date published: 2025-01-23

Certificate Traceable to NIST

Asked by: DoctorKong
Thank you for your inquiry for this rotameter. Unfortunately, there is no option for a NIST certificate for this series, you may consider the FL-3600, 3700, 3800, and 3900 series.
Answered by: Application Engineer JC
Date published: 2021-01-26

How do I read the flow meter / take the reading of FLDA3212ST model? Do I read the float at the top, middle or bottom? The model we got is FLDA3212ST

Asked by: Cathy2023
Thank you for your inquiry about the rotameters. The Rule of Thumb is the highest and widest part of the float.
Answered by: Application Engineer JC
Date published: 2023-03-11
  • y_2026, m_8, d_9, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_en_CA, sid_FLDN3301ST, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration