Asense-GH
Sensor de Dióxido de Carbono, Invernadero, 0-2000 PPM, Temperatura y Relé, PCB con Recubrimiento Conformal, con Pantalla
- Invernaderos
- Casas de cultivo
- Cervecerías
- Agricultura interior
- Granjas de champiñones y horticultura
Asense-GH
Desde
Resumen del Producto
- Exactitud ± 30 ppm, ±3 %
- Detalle de Exactitud CO2
- Homologaciones Directiva RoHS 2011/65/UE, EMC 2004/108/CE, 92/31/CEE incluyendo las enmiendas de la Directiva de marcado CE 93/68/CEE
- Calibración Algoritmo Senseair ABC (Corrección Automática de Línea Base)
- Rango de medición de CO2 0 a 2000 PPM
- Salida de control 1 x SPDT
- Resolución DAC 10 bits, 10 mV / 0,016 mA
- Banda muerta 100 ppm
- Tipo de pantalla LCD
- Conexión eléctrica Terminal de tornillo
- Salida eléctrica 0 a 20 mA, 4 a 20 mA, 0 a 10 Vcc, 2 a 10 Vcc
- Material del alojamiento ABS, policarbonato
- Nota sobre los materiales del alojamiento Caja; mezcla de PC y ABS, clasificación IP65, inflamabilidad UL94V-0 Tapa; plástico Makrolon® 6555, clasificación de inflamabilidad UL94V-0
- Clasificaciones del alojamiento IP65, UL94 V-0
- Altura 5.95 in
- Instalación 4-6 pies del suelo
- Longitud 1.85 in
- Opción de construcción de los materiales ninguno
- Rango de medición Máximo 7500 sq. ft.
- Orientación de montaje de montaje Soporte industrial para pared - Espacio
- Humedad de funcionamiento 0 a 95 % HR, sin condensación
- Temperatura de operación, máx. 122 °F
- Temperatura de operación mínima 32 °F
- Detalle de salida Out 1 (CO2): 0/2-10V, 0/4-20 mA, 0-2000 ppm Out 2 (Temp): 0/2-10V, 0/4-20 mA, 32º a 122ºF / 0º a 50ºC Out 3 Relay: N.O.; 1A @ 50 Vca / 24 Vcc
- Consumo de energía 3 W
- Protección Fusible PTC (auto restablecimiento) en retorno de señal M, seguro contra cortocircuitos
- Repetibilidad ±20 ppm ±1 % del valor medido
- Tiempo de respuesta <10 segundos a 30 cc / caudal mínimo, <3 minutos tiempo de difusión
- Tiempo de muestreo Nota Tiempo de difusión (T1/e): < 3 minutos
- ID de serie Asense-GH
- Temperatura de almacenamiento, máx. 158 °F
- Temperatura de almacenamiento, mínima -40 °F
- Tensión de alimentación 19 a 29 VCA/VCC
- Rango de medición de temperatura -4 a 140 °F
- Punto de disparo Nota 1000 ppm (ajuste de fábrica)
- Peso 0.812 lb
- Ancho 3.33 in
- Deriva del cero ± 10 ppm
Supported Applications
The ACI aSENSE GH series is a CO₂ and temperature transmitter designed for monitoring carbon dioxide levels in areas with elevated concentrations, specifically greenhouses. The product overview identifies additional applications including grow houses, breweries, indoor agriculture, mushroom farms, and horticultural settings.
Operating Conditions & Performance
The series utilizes non-dispersive infrared (NDIR) technology with Eternal Quality Coating (EQC). Standard measurement ranges are 0 to 2000 ppm for CO₂ and -4° to 140°F (-20° to 50°C) for temperature. Extended CO₂ ranges of 2000 to 10,000 ppm are available via factory set or programming cable.
Performance specifications include an accuracy of ±30 ppm ±3% of reading for standard CO₂ measurements and ±1.8°F (1°C) for temperature. Extended range accuracy is listed as +/- 30 ppm and +/- 5% of reading. The relay deadband/hysteresis is factory set to 100 ppm, with a trip point at 1000 ppm.
Operating conditions require an ambient temperature between 32°F to 122°F (0°C to 50°C) and relative humidity of 0 to 85% RH non-condensing. The unit features an IP65 enclosure rating with a flammability rating of UL94V-0 for both the PC & ABS blend box and Makrolon® 6555 plastic cover.
Response time (T1/e) is less than 3 minutes, with a warm-up time under 1 minute to reach full specifications in 15 minutes. The sensor life exceeds 15 years, and annual zero drift is less than +/-10 ppm. Pressure deviation impacts readings at +1.6% per 0.145 psi (1 kPa) from normal pressure.
Configuration Options
The aSENSE GH series supports configurable outputs, housing options, and communication interfaces to meet specific installation needs:
- Outputs: Out 1 provides CO₂ data (0/2-10V or 0/4-20 mA); Out 2 provides temperature data (0/2-10V or 0/4-20 mA, covering 32° to 122°F / 0° to 50°C). Out 3 is a Normally Open relay rated at 1A @ 50 VAC / 24 VDC.
- Display: A 4-digit, 7-segment LCD displays ppm and °F. Status LED indicators include Yellow for Maintenance Support and Red for Closed Relay.
- Housing & Protection: The unit features a conformally coated PCB and filter-equipped housing to protect against dust and high humidity. Electrical connections use 0.00232 in² (1.5 mm²) screw terminals with PTC fuse protection on signal return M.
- Communication Options: An optional Modbus RS485 communication board is available for data integration.
Key Product Differences
The primary model in the series is ASENSE-GH-LCD (Item #144119), described as an aSENSE Greenhouse unit with CO₂, Temperature, Relay, and Display. The datasheet notes that voltage outputs are recommended for temperature measurements to maintain specified accuracy.
Configuration changes can be made using the TTL-232R-3V3 programming cable (Item #134207) and UIP5 software. Custom calibration is available as an accessory (A/CUSTOM CAL GAS*, Item #140970). The series includes approvals for RoHS directive 2011/65/EU, EMC 2004/108/EC, and 92/31/EEG including amendments by the CE-marking Directive 93/68/EEC.