Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

PX2780

Barometric Pressure Transducers with Terminal Strip

Models In Stock
  • Systèmes de surveillance environnementale
  • Systèmes de mesure météorologique
  • Enregistrement des données environnementales
  • Surveillance des laboratoires et des stations d'essai
PX2780
From $ 1,144.26
Models In Stock
Barometric Pressure Transducers with Terminal Strip PX2780 PX2780
loading all models
Product Overview
  • Pression d'éclatement 29 psi maximum
  • Température compensée, max 60 °C
  • Température compensée, min -40 °C
  • Connexion électrique Borne à vis amovible
  • Puissance électrique 0 à 5 V
  • Compatibilité avec les fluides Air sec propre / gaz inerte, Gaz combustibles, Air ambiant / CVAC, Gaz inertes / non réactifs
  • Montage Plaque de montage
  • Température de fonctionnement, max 60 °C
  • Température de fonctionnement, min -40 °C
  • Résistance de sortie <10 Ω
  • Signal de sortie Tension
  • Taille du raccordement au process 1/8 po
  • Type de raccordement au process Raccord cannelé
  • Pression d'épreuve Jusqu'à 1500 hpa
  • Résolution 0,1 hPa
  • Temps de réponse <100 ms>
  • Effet de sensibilité <± 0,09 % de l’échelle complète/50°C>
  • ID de série PX2780
  • Plage de réglage de l'amplitude ± 5 mV
  • Stabilité <± 0,1
  • Remarque sur la stabilité Stabilité à long terme : <± 0,1 hPa (mb)/an
  • Température de stockage, max 120 °C
  • Température de stockage, min -60 °C
  • Approvisionnement Remarque 9,5 à 28 Vcc (3 mA en mode fonctionnement, 1 µA en mode veille) circuit à 3 ou 4 fils
  • Tension d'alimentation 9,5 à 28 Vcc
  • Effet thermique sur l'erreur d'étendue, max ± 1 % pleine échelle
  • Décalage de préchauffage <0,1 hPa (mb) maximum
  • Temps de chauffe <1 sec>
  • Poids 137 g
  • Erreur de zéro/équilibre <± 0,18 % de l’échelle complète/50°C>
  • Échelle de réglage du zéro ± 5 mV

Supported Applications

The Omega PX2780 Series consists of high accuracy barometric pressure transducers designed for applications in industry and science where accuracy, fast dynamic response, and long-term stability are important. These units sense absolute pressure and convert it to a proportional high-level analog output. The series is intended for use with non-condensing air or gas.

Operating Conditions & Performance

The PX2780 operates within an ambient temperature range of -40 to 60°C (-40 to 140°F) and a process temperature range of -40 to 60°C (-40 to 140°F). Storage temperatures are rated from -60 to 120°C (-76 to 248°F). The unit features a response time of <100 ms. Accuracy varies by barometric range and temperature, expressed as RSS (Root Sum Square) of end point non-linearity, hysteresis, non-repeatability, and calibration uncertainty:

  • 500 to 1100 hPa (mb) Range: ±0.6 hPa at 20°C; ±2.5 hPa across -40 to 60°C.
  • 600 to 1100 hPa (mb) or 600 to 1060 hPa (mb) Range: ±0.5 hPa at 20°C; ±2.0 hPa across -40 to 60°C.
  • 800 to 1100 hPa (mb) or 800 to 1060 hPa (mb) Range: ±0.3 hPa at 20°C; ±1.5 hPa across -40 to 60°C.

The sensor resolution is 0.1 hPa (mb). The pressure rating is 1500 hPa (mb) with a burst pressure of 2000 hPa (mb).

Electrical Specifications

  • Excitation Voltage: 9.5 to 28 Vdc.
  • Output Signal: 0 to 5 Vdc (available with 3- or 4-wire circuit).
  • Power Consumption: 3 mA in operate mode; 1 µA in sleep mode.

Configuration Options

The series is packaged in a rugged stainless steel and polyester case. A removable 5-pin terminal strip (BL 3.5 screw clamp) facilitates connections, with four-wire connection recommended to avoid voltage drop in the negative power line.

  • Process Connection: ¼" barbed fitting (0.290 in diameter).
  • Housing Dimensions: Depth: 90.3 mm (3.56 in); Height: 76.7 mm (3.02 in); Width: 59.9 mm (2.36 in). Mounting hole diameter is 0.140 in.
  • Weight: 137 g (4.8 oz).

The unit includes a sleep mode that draws only 1 micro amp, allowing almost instant turn-on and reading for remote applications. It is shipped in sleep mode and requires an external trigger to activate; terminal 1 can be jumpered to terminal 4 for continuous operation.

Key Product Differences

The PX2780 series offers five specific model configurations distinguished by barometric range:

  • PX2780-500B5V: 500 to 1100 hPa (mb).
  • PX2780-600B5V: 600 to 1100 hPa (mb).
  • PX2780-600NB5V: 600 to 1060 hPa (mb).
  • PX2780-800B5V: 800 to 1100 hPa (mb).
  • PX2780-800NB5V: 800 to 1060 hPa (mb).

All models feature a high accuracy ceramic sensor coupled with a digital compensation circuit using a custom ASIC. Each unit comes complete with an NIST traceable calibration certificate and operator's manual.

Accessories

Pressure Snubbers to Protect Against Pressure Surges
From SGD32.92
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration