United Kingdom 0800 488 488 | Intl +44 (0) 161 777 6611 | Welcome to our new website, found an issue or bug? Please report it here
OM-CP-PRTEMP1000IS-Series-invalid
Intrinsically Safe Rugged Pressure and Temperature Recorder
- Intrinsically Safe
- Rugged
- Programmable Start Time
- Real-Time Operation
OM-CP-PRTEMP1000IS-Series-invalid
From
£
675.49
Product Overview
- Accuracy Detail Calibration Accuracy : Pressure: 2% FSR, 0.25% @ 25°C typical; Time Accuracy : 1 minute/month at 20°C, (RS-232 port not in use); Pressure Repeatability : ± 0.5% FSR; ± 0.2% typical
- Approvals CE, FM
- Battery life up to 1 yr
- Battery Size and Type 3.6V Li-ion
- Baud Rate 2400
- Calibration Digital calibration through software and automatically recorded within device
- Calibration Accuracy Temperature : ±0.5°C, Pressure : 2%
- Data Interface USB, RS232
- Diameter 33 mm
- Frequency Response Pressure Response Time: 0.1 ms
- Humidity Range 0 to 100% RH
- Length 163 mm
- Materials Stainless Steel
- Measuring Temperature Range, Max 80 °C
- Measuring Temperature Range, Min -40 °C
- Memory 16,383 Readings
- Millivolt Range N/A
- Number of Measurements 2
- Operating Temperature, Max 80 °C
- Operating Temperature, Min -40 °C
- Measurement Pressure, Max 500 psi
- Measurement Pressure, Min 0 psi
- Pressure Repeatability ± 0.5%
- Pressure Sensor Type Silicon Strain Gage
- Measurement Pressure Type Absolute
- Process Connection Size 1/4 in
- Process Connection Type NPT Male
- Real Time Recording The device may be used with PC to monitor and record data in real-time
- Resolution Pressure : 0.05 psi, Temperature: 0.1°C
- Sampling Rate 0.5 Hz (2 seconds between updates)
- Sampling Rate Note 1 reading every 2 seconds, to 1 every 12 hours
- Series ID OM-CP-PRTEMP1000IS-Series-invalid
- Software Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit)
- Start Modes Delayed Start, Immediate Start
- Supply Power Type Battery
- Temperature Sensor Type Silicon Diode
- Time Accuracy 1 minute/month
- Weight 338 g
Supported Applications
The Omega OM-CP-PRTEMP1000IS is an Intrinsically Safe Rugged Pressure and Temperature Recorder, part of the NOMAD® Family. Designed for hazardous environments, this series accurately monitors and records pressure and temperature in air conditioning systems, chilled water, hot water, air, gas, oil, and steam pressure systems.
Operating Conditions & Performance
The recorder operates within an ambient and process temperature range of -40 to 80°C (-40 to 176°F) with a humidity rating of 0 to 100% RH. It utilizes a semiconductor temperature sensor and a rugged stainless steel pressure strain gauge.
- Accuracy: Temperature accuracy is ±0.5°C; Pressure accuracy is 2% FSR, or 0.25% @ 25°C typical.
- Repeatability: ± 0.5% FSR; ± 0.2% typical.
- Response Time: 0.1 ms (10 to 90% FSR).
- Safety Certification: FM Certified Intrinsically Safe for Class I, Division 1 groups A, B, C and D; non-incendive for Class I, Division 2, groups A, B, C and D. CE marked.
Configuration Options
The series supports multiple pressure ranges configured via model suffixes:
- psia Ranges: 0 to 30 psia, 0 to 100 psia, 0 to 300 psia, 0 to 500 psia, 0 to 1000 psia, and 0 to 5000 psia.
- psig Ranges: 0 to 30 psig, 0 to 100 psig, 0 to 300 psig, and 0 to 500 psig.
Data is stored in non-volatile memory with a capacity of up to 16,383 readings. Reading intervals are user-programmable from once every two seconds to once every twelve hours. The device features a common ¼" male NPT process connection and can be adapted to almost any pressure fitting.
Key Product Differences
The OM-CP-PRTEMP1000IS series is distinguished by its intrinsically safe certification for hazardous locations, differentiating it from standard data loggers. The housing material is stainless steel with overall dimensions of 32 x 163 mm (1.25 x 6.4") and a weight of 338 g (12 oz).
Power is supplied by an included 3.6V lithium battery; the OM-CP-BAT102 replacement part number applies for future maintenance. Data retrieval requires an interface cable, such as the OM-CP-IFC200 Windows software and 1.8 m (6') USB interface cable, connecting via PC serial, RS-232C COM or USB at 2400 baud.
Optional configurations include:
- NIST Calibration: Add suffix “-CERT” to the model number for a NIST calibration certificate (temperature only).
- FDA Compliance Package: OM-CP-SVP-SYSTEM provides an FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook and software package.
Software & Drivers