Accuracy ± 0.05 %
Accuracy Detail Thermocouple K: ±0.05% ±0.5°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), E: ±0.05% ±0.7°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), J: ±0.05% ±0.7°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), T: ±0.05% ±0.7°C (±20 Mv), R,B: ±0.05% ±1°C (±20 Mv), U,L: ±0.05% ±1°C, W-WRe26, PrRh40-PtRh20, NiMo-Ni: ±0.1% ±1°C, N: ±0.1% ±0.1°C, Platinel II: ±0.1% ±0.1°C (±20 Mv), ±0.1% ±1°C (±40 mV, ±80 mV), RTD: ±0.05% ±0.3°C, DC Voltage: ±0.05% ±1 digit
Alarm Note Alarm Types: High limit, low limit, Alarm Setting Method: Individual setting for each point four levels/ channels
Approvisionnement Remarque Power Voltage: 90 to 264V, Power Frequency: 50/60Hz ±2%
Battery Size and Type Li-ion
Battery life up to 5 yr
CMRR 130 dB
Chart Length 20000 mm
Chart Note Fan-fold type; overall width 318 mm (12.5"), total length 20 m (65.6'); effective recording width 250 mm (10") (analog recording)
Chart Speed 1 to 1,500 mm/h
Chart Width 250 mm
Common Mode Voltage 30 Vac
Couleur d'enregistrement Analog Recording: Red, Purple-Red, Orange, Brown, Green, Yellow-Green, Blue-Green, Purple, Purple-Blue, black, Digital Recording and Logging: Black
Cutout Dimensions 388 x 248 mm
Data Interface USB
Data Interface Note Inside of front door, USB1.1, full speed 12 mbps, bulk transfer, Control transfer and Parameter setting for exclusive application
Dielectric Strength Between Primary Terminals and Protective Conductor Terminals: 1 minute at 1500 Vac, Between Secondary Terminals and Protective Conductor Terminals:1 minute at 500 Vac, Between Primary Terminals and Secondary Terminals: 1 minute at 1500 Vac
Display Note Color LCD panel RGB (640 x 240 dot), Size: 149.8 W x 57.4 mm H, Setting Display: Common to digital display Display Contents: Digital display, Channel Display: One-point/multiple points continuous/sequential indication change, Display Measuring Value of Each Channel: One-point/multiple points continuous/sequential indication change, Clock Display: Hour/Minute/ Second/Tag/Unit. Alarm Display: Occurrence CH No, data is displayed in red when alarm occurs
Display Type LCD
Dérive de température 0.1%/10°C
Détails relatifs au transport et au stockage Transportation Condition: Ambient Temperature/Humidity ,Range: -20 to 60°C (-4 to 140°F), 5 to 90%RH (no dew condensation),Vibration: 10 to 60 Hz, 4.9 m (16')/ S2 (0.5G or less),Impact: 392 m (1.3')/S2 (approx. 40G or less); Storage Condition: Ambient Temperature: -20 to 60°C (-4 to 140°F), 5 to 90% RH (no dew condensation),
Détection de rupture du capteur Thermocouple Burn-Out: Select with/without burnout for each input
Electrical Connection Note Terminal Board: Detachable type, removable for wire connection
Fréquence d'échantillonnage 0.1 sec/channel
GrossWeightValue 0.15
Height 260 mm
Humidité relative 20 to 80% RH
ID de série RD5100-Series
Input Note Input Correction: Zero/span correction and shift correction for each channel
Input Resistance 1 MΩ
Insulation Resistance Between Primary Terminals and Protective Conductor Terminals:20MΩ or more at 500 Vdc, Between Secondary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc, Between Primary Terminals and Secondary Terminals: 20MΩ or more at 500 Vdc
Interface de données USB
LED Indicators Record On: Lights during recording; LED, Key Lock: Lights during key lock, Alarm: Lights during alarm activated; LED, Chart End: Lights just before record ending, Fail: Lights during unit abnormal time
Largeur 400 mm
Length 300 mm
Loop Resistance, Max Thermocouple Inputs, DC Voltage Input (10 mV): 500Ω or less (without burnout), DC Voltage Input (Except 10 mV): 100Ω or less Resistance, Thermometer Inputs: 10Ω or less/ line, three lines are common, Pt100, JPt100
Materials ABS, Soda glass, Steel
Measurement Range Note Thermocouple: K: Reference Range: ±20 mV: -200 to 500°C, ±40 mV: -200 to 900°C, ±80 mV: -200 to 1370°C, E: Reference Range: ±20 mV: - -200 to 250°C, ±40 mV: -200 to 500°C, ±80 mV: -200 to 900°C, J : Reference Range: ±20 mV: - -200 to 350°C, ±40 mV: -200 to 700°C, ±80 mV: -200 to 1200°C, T: Reference Range: ±20 mV: - -200 to 400°C, R: Reference Range: ±20 mV: 0 to 1760°C, B: Reference Range: ±20 mV: 0 to 1300°C, N : Reference Range: ±20 mV: 0 to 600°C, ±40 mV: 0 to 1000°C, ±80 mV: 0 to 1300°C, W-WRe26: Reference Range: ±80 mV: 0 to 2315°C, W-WRe26: Reference Range: ±80 mV: 0 to 2315°C, PtRh20-PrRh40: Reference Range: ±20 mV: 0 to 1888°C, U : Reference Range: ±20 mV: -200 to 350°C, ±40 mV: -200 to 600°C, L : Reference Range: ±20 mV: -200 to 350°C, ±40 mV: -200 to 700°C, ±80 mV: -200 to 900°C, Nimo-Ni: Reference Range: ±80 mV: -50 to 1310°C, Platinel II: Reference Range: ±20 mV: 0 to 500°C, ±80 mV: 0 to 950°C, 0 to 1395°C RTD: Reference Range: 50Ω: -50 to 50°C , 100Ω: -100 to 130°C, 200Ω: -200 to 250°C, 300Ω: -200 to 550°C Voltage: ±10 mV, ±20 mV, ±40 mV, ±80 mV, ±1.5 V, ±2.5 V, ±5 V, ±10 V
Measurement Type Thermocouple, RTD, Voltage
Mounting Panel Mount
NMRR 50 dB
Nombre de canaux 24
Nombre de relais N/A
Number of Channels 24
Number of Relays N/A
Operating Environment Reference Operating Condition: Ambient Temperature/Humidity Range: 21 to 25 °C (70 to 77°F), 45 to 65% RH,Power Voltage: 90 to 264V,Power Frequency: 50/60Hz ±2%,Attitude: Forward/Backward/left/right within 3°,Warm-Up Time: 1 hour or longer; Normal Operating Condition: Ambient Temperature/Humidity ,Range: 0 to 40 °C (32 to 104°F), 20 to 80% RH,Power Voltage: 90 to 264V,Power Frequency: 50/60Hz ±2%,Attitude: Forward/backward/left/right within 3°
Operating Temperature, Max 40 °C
Operating Temperature, Min 0 °C
Plage de mesure de la température K: -200 to 1370°C, E: -200 to 900°C, J: -200 to 1200°C, T: -200 to 400°C, R: 0 to 1760°C, B: 0 to 1300°C, N: 0 to 1300°C, W-WRe26: 0 to 2315°C, B: 0 to 1888°C, L: -200 to 900°C, Nimo-Ni: -50 to 1310°C, Platinel II: 0 to 1395°C, RTD: -200 to 550°C
Plage de mesure de tension ± 10 mV, ± 20 mV, ± 40 mV, ± 80 mV, ± 1.5 V, ± 2.5 V, ± 5 V, ± 10 V
Poids 15 kg
Power Consumption 100 VA
Puissance nominale du commutateur 3 A @ 100 to 240 Vac
Remarque concernant l'enregistrement Recording System: Raster scan system, 10-color wire dot printing; Compensation: Independent setting of zero spans are available, Operation: Record On/Off: Recording operation ON/OFF*, Data Print: Printing measuring data*, Feed: Fast-forwarding chart paper
Remarque sur la puissance nominale du commutateur 100 to 240 Vac, 3 A resistance load
Résolution Input: 1/40,000; Display: Thermocouple, RTD: 0.1°C, DC Voltage: 1 µV(±10 mV, ±20 mV), 10 µV(±40 mV, ±80 mV), 100 µV(±1.25V, ±2.5V), 1 mV(±5V, ±10V)
Température de stockage, max 60 °C
Température de stockage, min -20 °C
Tension d'alimentation 100 to 240 Vac
Type RTD 100 Ω pt or Jpt sensor; 3-wire Pt100
Type d'approvisionnement électrique AC
Type de commutateur SPST NO
Type de thermocouple J, K, T, E, N, R, S, U, B, G, L, P, NiMo-Ni, PrRh40-PtRh20
Voir toutes les spécifications Montrer moins
Enregistreur graphique hybride, 250 mm (10") RD5120 RD5120

Accessoires

Logiciel d'acquisition de données
C$767.94 / each
0 En stock
Logiciel de programmation des paramètres
C$767.94 / each
0 En stock
Zaila Logiciel d'analyse de données
C$251.62 / each
1 En stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration