PX600

Subminiature, Flush Diaphragm Pressure Transducers

Transducteurs de pression à diaphragme affleurant subminiatures
Modèles en stock
  • All Stainless Steel Diaphragm and Threaded Side Wall Construction
  • Rugged Stainless Steel Case Protects Components in Industrial Environments
  • Uses a Standard 5 Vdc Regulated Power Supply for Maximum Versatility
  • Custom Subminiature Design Techniques Provide Small Size and Preserves Accuracy
PX600
À partir de C$ 1,249.72
Modèles en stock
Transducteurs de pression à diaphragme affleurant subminiatures PX600 PX600
loading all models
Aperçu du produit
  • Accuracy ± 1 %
  • Accuracy Class > 0.25%
  • Accuracy Detail ± 1% FS (linearity and hysteresis combined)
  • Additional Features 1 None
  • Burst Pressure Note 400% range
  • Compensated Temperature, Max 71 °C
  • Compensated Temperature, Min 16 °C
  • Electrical Output 2 mV/V
  • Enclosure Material 17-4 PH Stainless Steel
  • Input Resistance 350 Ω
  • Insulation Resistance 5 MΩ @ 75 Vdc
  • Materials, Wetted FKM
  • Operating Temperature, Max 121 °C
  • Operating Temperature, Min -54 °C
  • Output Resistance 350 Ω
  • Repeatability Error ± 0.1% FS
  • Sensitivity 2 mV/V nominal
  • Sensitivity Effect ± 0.036% reading/°C
  • Series ID PX600
  • Supply Power Note 5 Vdc @15 mA
  • Supply Voltage 5 Vdc
  • Weight 14 g
  • Zero/Balance Error ± 3% FS
Les transducteurs de pression à membrane affleurante subminiatures de la série PX600 sont les plus petits d'Omega. Ils offrent une construction robuste et une précision de ±1 % pour une utilisation industrielle. Ils fournissent une sortie électrique de 2 mV/V et sont disponibles dans des plages de pression de 200 à 10 000 psi, garantissant des performances fiables dans des environnements exigeants.

Accessoires

Amortisseurs de pression pour se protéger contre les variations de pression
Depuis C$27.12
0 En stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Hi, Can the PX600-10KGV be ordered with TWISTED TEFLON wires (or is it already the case in this product), also do you offer the same transducer with 15000 psi range ? Thanks Omar

Asked by: Omar
Thank you for contacting Omega. The PX600 series transducers come standard with a Teflon insulated lead wire. Sorry but the highest range available is the 0 to 10,000 psi range.
Answered by: RFengineer
Date published: 2019-10-01

What is the safe overload of this transducer? (Specifically the 5K and 10K variants) Is there a possibility to adapt this thread to SAE-2 (5/16-24 per J1926-2) with a custom thread adapter or would that blow out at high pressures near FS?

Asked by: JChez
Maximum safe overpressure (proof pressure) is 150% of the sensors rated pressure range. A 5/16-24 thread has a max pressure of 6000 PSI so it would work for the 10,000 PSI range unit
Answered by: Applcations Engineer JK
Date published: 2023-03-11

What is the response time of these sensors? I would like to use these to characterize a gear pump and need to be able to capture pressure pulses over 400 Hz.

Asked by: ej82
Thank you for your inquiry While this sensor has not been specifically tested for response time, typical for strain gage pressure sensors is a response time of 1kHz. Hope this helps.
Answered by: application engineer je
Date published: 2020-09-23

Does these contain silicon oil in the sensing element?

Asked by: SteveT
The PX600 Series pressure transducers do not contain any type of oil fill.
Answered by: JK Applications Engineer
Date published: 2024-03-23

When threading the PX-600 into the housing, we noticed an increase on the pressure when the torque increase. Is this behavior considered normal? if so, could you provide the recommended torque setting for the installation?

Asked by: rafaeldms27
It is normal to see an increase in the output signal tightening the sensor during installation. Design engineering suggests a torque value of 260 in-lbs. You would then correct for the reading offset at zero pressure in the scaling of your readout device.
Answered by: Applicatrions Engineer JK
Date published: 2023-09-11

Do you have mounting dimensions details for 3/8-24 UNF threads? there is no information in the drawing about mounting the sensor. Thank you

Asked by: Ben62
Yes. There is a dimensional drawing for the mating port for the PX600. Please contact a technical representative at pressure@omega.com to acquire the drawing
Answered by: Applicatrions Engineer JK
Date published: 2020-08-08

What does the small "balance" circuit board do that you find in the wiring of the sensor do? Is this board the same for all sensors of this type, or is the board specific to each sensor?

Asked by: Henrik
The external balance board is for designed to correct for any zero offset you have in the internal strain gage bridge internal to the sensor. It's external due to the very small size to the body of sensor. Each balance board is trimmed specifically to the sensor. They are not interchangeable.
Answered by: Applicatrions Engineer JK
Date published: 2022-11-18
  • y_2026, m_5, d_14, h_12CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_en_CA, sid_PX600-10KGV, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 41ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration