Passer à la recherche Passer au contenu principal Passer à la navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

XTA-W5R26

Sondes thermocouples exotiques à température extrême

Modèles en stock
  • Gainages
    • Tantale
    • Molybdène
    • Platine/Rhodium
    • Inconel 600
  • Éléments de thermocouple
    • Tungstène/Rhénium
    • Platine/Rhodium
  • Isolations
    • Oxyde d'hafnium (HfO2)
    • Magnésie (MgO)
    • Alumine (Al2O3)
  • Connecteur d'accouplement vendu séparément!
XTA-W5R26
À partir de C$ 475.88
Modèles en stock
Sondes thermocouples exotiques à température extrême XTA-W5R26 XTA-W5R26
loading all models
Aperçu du produit
  • Matériau de l'alliage (-) Platinum - 6% Rhodium
  • Matériau en alliage (+) Platinum - 30% Rhodium
  • Code couleur standard ANSI
  • Type de jonction Non mis à la terre
  • Température de fonctionnement, min 0 °C
  • Taille du raccordement au process N/A
  • Température minimale du processus 0 °C
  • ID de série XTA-W5R26
  • Type de capteur de température Thermocouple
La série Omega XTA-W5R26 propose certaines des sondes thermocouples exotiques disponibles à ce jour, conçues pour des applications à très haute température pouvant atteindre 2315 °C (4200 °F). Fabriquées à partir de matériaux robustes et d'alliages spéciaux, ces sondes vous permettent d'effectuer des mesures précises dans les fours, les chambres à vide, les laboratoires de recherche et les processus métallurgiques où les capteurs standard ne sont tout simplement pas à la hauteur.

Ce qui distingue le XTA-W5R26, c'est son utilisation d'éléments en tungstène-rhénium ou en platine-rhodium, combinés à des matériaux de gainage et d'isolation haute performance tels que le tantale, le molybdène, l'hafnium, la magnésie ou l'alumine. Selon leur configuration, ils fonctionnent parfaitement dans des atmosphères inertes, oxydantes, réductrices ou sous vide.

Équipées de plusieurs types de terminaisons, notamment des connecteurs en céramique ou des fils conducteurs longs, les sondes sont conçues pour offrir à la fois flexibilité et durabilité.  La sonde XTA-W5R26 est idéale pour les mesures de précision où l'intégrité du signal est primordiale.

Comme tous les produits Omega, cette série bénéficie d'un contrôle qualité rigoureux, d'options d'étalonnage et d'un service client fiable. Si vous avez besoin de mesures de température qui repoussent les limites, ces sondes thermocouples exotiques offrent à la fois des performances élevées et une stabilité à long terme.
Rated 1 out of 5 by from Find a different supplier My issue with these probes is two-fold: first with the product itself and second with trying to address the product issues. The probes are not consistent from one to the next and I have contacted the engineering team to ensure that they are manufactured with tight tolerances, which they claim they do, but the following has been some of our experience. When changing thermocouples, we see high levels of temperature variation from one to the next which Omega’s provided calibration data does not account for, we have also seen vast differences in the temperature readings within a dual-probe thermocouple itself (i.e., one side reads 1000º while the other is reading 950º), we have been provided with dual thermocouples that have had the wires crossed, and so on. We are currently trying to get Omega to replace a few probes that were faulty and that has been a whole saga. First, they tried to claim that they were out of warranty, then when we were finally able to send them in and checked back a month later to find out the status, we were informed that Omega did not ever receive the probes. Upon sending them the signed delivery confirmation (then calling customer service a week later after not hearing anything) they informed us that they found the probes and could now start evaluating them. It has now been several months with zero updates even though we reach out for status updates every few weeks (which we imagine must be as annoying for them as it is for us). Do what you will with this information, but we found a new supplier.
Date published: 2021-03-17
  • y_2026, m_4, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_XIN-P10R-U-125-30-A-SX-12-DUAL, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Can this be put directly into an oven?

Asked by: bobbo
The metal probe portion sheath can be inserted into the oven but the connector is rated to only 650C so should not be exposed above it.
Answered by: ApplicationEngineerANB
Date published: 2024-10-25

Hi, Is Platinum-Rhodium Alloy TC (coded as XPA, https://assets.omega.com/spec/XTA-W5R26.pdf) compatible with fluorine? if yes, then what is the maximum temperature that it can work at in fluorine gas medium? If not, what TCs are compatible? Thanks

Asked by: JimmyC
Hi Jimmy, Thank you for the inquiry. We offer a variety of sheath materials. We can provide test data on the sheath alloys used. End user will need to verify if their specific gas concentration, temperature , and presures will be compatible with the alloys used. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-07-25

What kind of reader / data logger can be used to record and view the temperature readings of these ultra high temperature probes?

Asked by: Jamie B
Hi Jamie, Thank you for the inquiry. Some options; https://www.omega.com/en-us/data-acquisition/data-loggers/temperature-and-humidity-data-loggers/hh806/p/HH806AU https://www.omega.com/en-us/data-acquisition/data-loggers/multichannel-programmable-and-universal-input-data-loggers/om-cp-octpro-logger/p/OM-CP-OCTPRO And more options available. For more detail please forward request to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-10-29
  • y_2026, m_4, d_27, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_XIN-P10R-U-125-30-A-SX-12-DUAL, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration