Passer à la recherche Passer au contenu principal Passer à la navigation

Besoin d'aide? Appelez-nous: 1-800-663-4209

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

RTD-800-ClassB

Capteurs RTD de classe B pour applications spécialisées

Class B RTD Sensors for Specialized Applications
Modèles en stock
RTD-800-ClassB
À partir de C$ 157.25
Modèles en stock
Class B RTD Sensors for Specialized Applications RTD-800-ClassB RTD-800-ClassB
loading all models
Aperçu du produit

Accessoires

accessories

Platinum Series Versatile High Performance PID Controllers
C$554.32 / each
4 En stock
PLATINUM™ Series Digital Panel Meters
C$391.68 / each
0 En stock
High Accuracy PT100 RTD Input Thermometers
C$375.16 / each
37 En stock
Rated 3 out of 5 by from Good product We have been ordering and using the RTD-850-B for at least 6 months now. We have used about 9 of these RTDs. Performance wise they work well. However durability is not great. The adhesive holding the RTD into the well often breaks loose from sustained operations between 200-210 C. Product is rated for 230 C.
Date published: 2017-08-21
  • y_2026, m_11, d_13, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.50
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_RTD-805-B, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT

The datasheet states +/-0.12%, but also states class B accuracy per IEC 60751. Class B from my understanding is +/-0.3C + 0.005*t where t is the temperature being measured, in absolute value. Is 0.12% correct for the whole temperature range?

Asked by: joebot5
Thank you for your inquiry joebot5. According to our documentation for Class B accuracy, the formula should be the Class B = ±(0.3 + 0.005*t)°C or 100.00 ±0.12 O at 0ºC. That's correct, the accuracy applies to the entire range.
Answered by: Application Engineer MC
Date published: 2022-08-25
  • y_2026, m_11, d_13, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.50
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_RTD-805-B, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 47ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration