Portable Temperature and Humidity Data Logger with LCD DisplayOM-HL-SH-SeriesOM-HL-SH-Series
L'aperçu du produit
Applications
Building and Maintenance, Food and Beverage
Battery life
up to 6 mo
Battery Size and Type
Alkaline AAA
Data Interface
USB
Display Type
LCD
Display Type Note
37L X 17H mm
Form factor
Handheld/Wall Mount
Number of Measurements
2
Operating Temperature, Max
25 °C
Operating Temperature, Min
0 °C
Process Temperature, Max
70 °C
Process Temperature, Min
-20 °C
Recorder Height
92 mm
Recorder Length
57 mm
Recorder Width
20 mm
Samples,Max
43000
Sampling Rate
60 seconds between updates
Sampling Rate Note
sampling interval is 60 secs, logging interval is 300 secs
Sampling Time
1/300 sec
Sampling Time Note
sampling interval is 60 secs, logging interval is 300 secs
Supply Power Type
Battery/USB
Temperature Accuracy
± 0.5 °C
OM-HL-SH Operation Instruction
The OM-HL-SH Series of portable temperature and temperature/humidity data loggers are easy-to use, versatile and price competitive devices which can be used for a wide range of logging applications including coolers, freezers, greenhouses, museums, laboratories, shipping containers, warehouses, environmental monitoring and food storage.
With 100~200ms sensor response time, these data loggers are capable of sampling as fast as 1 second and logging between once every 2 seconds to 24 hours. Both Models OM-HL-SH-T and OM-HL-SH-TH can store a total of 43,000 temperature only or 43,000 temperature & 43,000 humidity measurements in memory. Excellent user experience and cost effective makes this OM-HL-SH series one of the best temperature/humidity logging solutions in the market.
NIST Traceable calibration model OM-HL-SH-TH-CAL is available to order as well as the external probe model OM-HL-SH-EX coming with standard 3 meter long IP65 temperature and humidity probe. See the following picture of EX model.
Specifications Temperature Range: OM-HL-SH-T: -20 to 70°C (-22 to 158°F) OM-HL-SH-TH: -20 to 70°C (-22 to 158°F) OM-HL-SH-EX: -40 to 85°C (-40 to 185°F) Temperature Accuracy: OM-HL-SH-T: ± 0.5°C OM-HL-SH-TH: ± 0.5°C OM-HL-SH-EX: ± 0.5°C Record Volume: 43,000 Temperature Points (OM-HL-SH-T) or 43,000 Temperature & 43,000 Humidity Points (OM-HL-SH-TH & OM-HL-SH-EX) Humidity Range: OM-HL-SH-TH: 0-95% RH OM-HL-SH-EX: 0-100% RH Humidity Accuracy: OM-HL-SH-TH: ± 5% RH OM-HL-SH-EX: ± 5% RH Resolution: Temperature: 0.1°C / Humidity: 0.1% RH Power Supply: 2 x AAA Batteries, 1.5V Battery Typical Battery Life: 1 year
OM-HL-SH Software Setup
Logging Mode: Stop on memory full; when data logger operation is start/stopped by user intervention via button press, last memory location is retained Logging Interval: 2 Secs to 24 Hrs Sampling Interval: 1 Sec to 240 Secs Sensor Response Time: 100~200ms Display: LCD display LCD Size: 36 L x 16 W mm (1.41 x 0.6") Dimensions: 92 L x 57 W x 20 Dia mm (3.6 x 2.2 x 0.78") Weight: 150g (5.29 oz)
Logpro Recorder Analysis Software OM-HL Logpro Software is comprehensive temperature and humidity recorder data analysis software designed to log attribute settings, download logger data efficiently, graphically analyze data, and export the data to Excel/PDF/BMP, and other formats.
The software interface is easy to use and efficient for ultimate data analysis. See the software instruction video for more details
Is there anyway to export data to .csv or to google sheets? In other words, is there anyway to access the raw data if I don't have Excel?
Asked by: Anonymous
Thank you for your question. Please send your request to DAS Engr Dept-DAS@OMEGA.COM.
Answered by: Cheetah
Date published: 2020-07-18
Can this equipment be calibrated to a known standard in particular Humidity
Asked by: ScottD
Thank you for your question. Please send your request to DAS Engr Dept-DAS@OMEGA.COM
Answered by: Raptor
Date published: 2024-03-04
Does it come with the probes?
Asked by: Anonymous123
Thank you for your question. Yes, comes with standard 3 meter long IP65 temperature and humidity probe
Answered by: Application Engineer PV
Date published: 2021-08-25
Hello, I would like to use the OM-HL-SH-EX Model inside a paint booth. Is there a protective sleeve available for the external probe sensor ?
Asked by: MikeH
Thank you for your question. Unfortunately, there is not.
Answered by: Application Engineer PV
Date published: 2022-09-09
Is there a way to increase the speed of data download? When the device is full, it takes around 15 minutes to get all the data to my PC. The OM-62 did the same in a few seconds.
Asked by: Temp_logger
Hello
Regarding your question, the download speed cannot be modified as it is dependent on the USB port capability
Answered by: JA Engineer
Date published: 2021-10-26
Can the software be setup to send a text or e-mail alert if RH or temp exceeds limits?
Asked by: hiker
Thank you for your question. Unfortunately, it cannot.
Answered by: Application Engineer PV
Date published: 2022-03-18
1. Can it display both Temperature and humidity during recording?
2. Can the data be download thro USB to computer and generate excel file?
Asked by: Eric Chung
Thank you for your question. Yes , the logger can display Temp and Humidity while logging and downloaded data can be imported into Excel. Please note that correct part number for Temperature and Humidity is OM-HL-SH-TH. https://www.omega.com/en-us/temperature-measurement/temperature-and-humidity-data-loggers/om-hl-sh-series/p/OM-HL-SH-TH?searchterm=om-hl-sh-th
Answered by: Application Engineer PV
Date published: 2023-02-02
With a sample interval of 240 s (4 min) will the logger recorder SINGLE points at the 30 minute log point or will it record what it has taken during that 30 minutes so....7 points if you are set at 240 seconds?
Asked by: Brand
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com