Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous vous trouvez en . Veuillez consulter votre site local en cliquant sur le lien ci-dessous pour accéder aux offres et à l'assistance régionales.

OM-CP-STATE101A

State Data Logger

Choisissez une variante

Measurement Type

C$195.42 / each

Article# OM-CP-STATE101A

En stock

Délai de livraison (si pas en stock):6 journées

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Battery Size and Type 3.6V Li-ion
Battery life up to 10 yr
Baud Rate 115200
Commodity Code 9029.20.5000
Data Interface USB
DepthValue 4.4
Display Measuring Units °C, °F, ft/min, k/h, kts, m/s, mph
Détail de la précision ±1 minute/month at 20°C, stand alone data logging
ECCN 3A992.a
Electrical Connection Removable Screw Terminal
GrossWeightValue 0.23
Height 1.4 in
HeightUoM IN
HeightValue 2.5
Impedance Input >60 kΩ
Internal Weak Pull-Up <60 μA
LED Indicators Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory
Length 0.6 in
Materials ABS, Aluminum
Measurement Type Voltage
Memory 406,323 readings; software configurable memory wrap
Memory Modes Yes
Multi Start/Stop Mode Note To Start the Device:Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The device has started logging To Stop the Device:Press and hold the pushbutton for 5 seconds, the red LED will flash for 3 seconds and then the green LED will flash for two seconds. The device has stopped logging
NetWeightValue 0.23
Number of Measurements 1
OkForExport true
Operating Temperature, Max 80 °C
Operating Temperature, Min -40 °C
Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
Précision ± 1 min/month
RRS Code 1
Real Time Recording The device may be used with PC to monitor and record data in real-time
Relative Humidity 0 to 95% RH non-condensing
Resolution 4 Hz
Samples,Max 0.25 sec
Sampling Rate 4 Hz (4 updates/second)
Software XP SP3/Vista/7 and 8 (32 and 64-bit)
Start Modes Delayed Start, Immediate Start, Push-button
Supply Power Type Battery
Taxonomy Level 1 MGI
Taxonomy Level 2 DL
Taxonomy Level 3 PO
Taxonomy Level 4 PO
Voltage Input Range 0 to 30 vdc
Weight 0.9 oz
WeightUoM LB
Width 2.2 in
WidthValue 5.7
Pays d'origine United States