1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
OM-140-Series
Portable Temperature/Humidity Data Loggers with USB Interface
Enregistreurs de données de température/humidité portables avec interface USB
Models In Stock
- One Button Starts/Stops Data Logging Without a PC
- Plug-and-Play USB 2.0 Interface No Need for Cables, Cradles or Docks
- Large Storage Capacity: 16,000 Pairs of Temperature and Humidity Readings
- 3½-Digit LCD Displays Real-Time Temperature and RH Readings, Device Working Status and “Memory Full” (OM-143 and OM-144 Only)
OM-140-Series
From
C$
161.08
Models In Stock
Product Overview
- Battery life up to 1 yr
- Battery Size and Type 3.6V Li-ion
- Data Interface USB
- Field of view 2:1
- Form factor Handheld
- GPP Measurement 0 - 1500 GPP
- Height 23 mm
- Infrared Thermometer Emissivity 0.95 (fixed)
- Length 125 mm
- Measurement Type Humidity, Infrared, Temperature
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -20 °C
- Relative Humidity Accuracy ± 3% RH
- Relative Humidity Accuracy Note ± 3% RH from 20 to 80% RH; ± 3.5% RH elsewhere
- Relative Humidity, Max 1
- Relative Humidity, Min 0%
- Relative Humidity Resolution 0.001
- Samples,Max 16000
- Samples Note 16,000 pairs of RH and temperature readings or 10,000 RH and temperature sets + IR readings
- Sampling Rate 10 Hz (10 updates/second)
- Sampling Rate Note Adjustable from 10 seconds to 12 hours
- Series ID OM-140-Series
- Supply Power Type Battery
- Temperature Accuracy ± 3.0 °C
- Temperature Accuracy Note ± 3.0°C for surface temperature measuremtn, ± 1 °C for ambiant temperature accuracy
- Temperature Measurement, Max 250 °C
- Temperature Measurement, Min -20 °C
- Temperature Resolution ± 0.1 °C
- Temperature Sensor Type IR
- Weight 200 g
- Width 43 mm
La série OM-140 comprend des enregistreurs de données de température/humidité compacts, économiques et alimentés par batterie, capables d'enregistrer sans surveillance la température ambiante et l'humidité relative (HR) d'un environnement pendant des jours, des semaines ou des mois. L'enregistreur de données OM-144 peut également mesurer et, en option, enregistrer les températures de surface vérifiées ponctuellement par un technicien à l'aide du thermomètre infrarouge (IR) intégré à l'appareil. En outre, ces appareils peuvent également calculer et afficher les niveaux d'humidité absolue en grains par livre (GPP) ou en g/kg. Également appelé " rapport de mélange ", le GPP est une mesure de l'humidité plus utile que l'HR pour les restaurateurs de dégâts causés par l'eau. En utilisant uniquement la HR, un restaurateur pourrait, sans le savoir, introduire de l'air humide (avec une HR faible mais un GPP élevé) pendant la phase de séchage d'un chantier.
L'enregistrement des données peut être démarré ou arrêté en appuyant sur un bouton de l'appareil, ce qui évite d'avoir à apporter un ordinateur portable sur le chantier. Une fois les données enregistrées et stockées, elles peuvent être téléchargées sous forme de fichier .txt sur n'importe quel PC équipé du système d'exploitation Windows® XP/7 ou 8 après avoir branché l'enregistreur de données sur l'un des ports USB de l'ordinateur. La mémoire flash interne de l'enregistreur de données est suffisamment grande pour stocker 16 300 paires de mesures de température et d'humidité relative ou, pour le modèle OM-144, près de 10 000 ensembles de mesures d'humidité relative, de température ambiante et de température de surface. Le produit est livré avec un mini-disque contenant les pilotes nécessaires pour connecter l'appareil à l'ordinateur, ainsi qu'un logiciel permettant d'afficher un fichier journal sous forme de tableau ou de graphique et/ou de l'exporter vers Microsoft Excel. L'exportation vers Excel est recommandée pour l'analyse sophistiquée des tendances et des données d'humidité et de température, ainsi que pour la détection facile des écarts inattendus.
L'enregistrement des données peut être démarré ou arrêté en appuyant sur un bouton de l'appareil, ce qui évite d'avoir à apporter un ordinateur portable sur le chantier. Une fois les données enregistrées et stockées, elles peuvent être téléchargées sous forme de fichier .txt sur n'importe quel PC équipé du système d'exploitation Windows® XP/7 ou 8 après avoir branché l'enregistreur de données sur l'un des ports USB de l'ordinateur. La mémoire flash interne de l'enregistreur de données est suffisamment grande pour stocker 16 300 paires de mesures de température et d'humidité relative ou, pour le modèle OM-144, près de 10 000 ensembles de mesures d'humidité relative, de température ambiante et de température de surface. Le produit est livré avec un mini-disque contenant les pilotes nécessaires pour connecter l'appareil à l'ordinateur, ainsi qu'un logiciel permettant d'afficher un fichier journal sous forme de tableau ou de graphique et/ou de l'exporter vers Microsoft Excel. L'exportation vers Excel est recommandée pour l'analyse sophistiquée des tendances et des données d'humidité et de température, ainsi que pour la détection facile des écarts inattendus.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
DR B from
So Far So Good
Been using two of these units for the past couple weeks and they are performing well. Temperature accuracy is as advertised (they give the exact same reading to the tenth of a degree C and these temps match other accurate devices I have. The relative humidity values vary by 0.5%, but this is in the advertised range. Very easy devices to set-up and to remove data..
Date published: 2016-12-26
Rated 4 out of
5
by
mccmfbgn from
Great value. Excellent product.
After 2 weeks of testing I'm going to give the OM-141 4 stars. If I could give it a 4.9 I would do that. I've only had one problem so far and it is not a showstopper.
I initially set the sampling rate to 30 seconds to collect and simulate a collection of many data-points, way more than we need), and in one week it had collected more data than the software seemed to download without a 'timeout' error being thrown. There needs to be a way to set the timeout value. When I put these in production we will set the sample rate to 12 hours, more than adequate for our needs, but I'd like to only download the data when I receive an alarm. if my freezers are doing well, I can foresee a timeout occurring if the time between downloads is sufficiently long to record a bunch of data-points.
In device setup, the sensitivity of the slider to set High/Low points is way too sensitive and I end up setting bounds slightly different from what I want. Not a big deal, but frustrating.
As I explore the software I am continually surprised by how many features are available. The best advice I can give to new users of the products is to "Read the **** manual".
Another problem we experienced had nothing to do with the device, but rather it was cockpit trouble: when we placed two of the device, I forgot to hit the start-button. I don't know what the solution would be on the OM141 to protect us from operator (me) error. Add that to your "would be a nice feature to have" list.
Date published: 2018-02-20
Rated 1 out of
5
by
Anyone from
Thermometer and RH with data log portable
It takes too long to changes in temperature. I regret purchase. Software to retrieve data is troublesome as well. I don’t recommend it.
Date published: 2023-07-27
Rated 3 out of
5
by
Lumidity from
OK for low budget
I wish I had purchased the 143. The 141 is hard to tell if it's Power On or Not.
Date published: 2018-09-08
Rated 1 out of
5
by
ThomasArnold from
Frequent software malfunctions
Purchased 4 of the base models of the OM-141. They worked the first time, well within advertised accuracy. Additional setups and data extraction work 10% of the time. Package software often has timeout errors even with small <100 data point sets. Frequently wipes data off devices for no reason as well. Manual and setup DVD provided no explanations for these peculiar cases
Date published: 2017-08-31
Rated 4 out of
5
by
power3153 from
great features
I bought this instrument a couple of weeks ago and its very helpful to monitor our
ac performance data.
Date published: 2017-07-23
Rated 5 out of
5
by
Rick W D from
Great out the box
Tested over and hour and checked. So far so good. Fixing to put them to work on mold lawsuit home and will follow up after recording for three weeks
Date published: 2017-07-19
The OM-140 series (141;142;143 and 144) are they suitable for the monitoring of ventilation temperature into the undergound mines ?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-09-23
I use Linux, not Windows. A few Qs: 1. What is the default setting for sampling rate? 2. Will the device appear as a storage device if plugged into a Linux kernel? 3. If yes to 2., will the .txt data file appear on the device? Thx
Thanks for your questions. Unfortunately, the OM-141 (or the OM-HL-SP) will not support Linux since both logger’s software is designed for Windows. However, we can recommend the product OM-HL-SP, the max logging rate is 1 sec and the default is set to 60 secs. Please contact us anytime with further questions.
Date published: 2019-05-15
Regarding the OM-141 temperature/RH datalogger software, is it available for download as an alternative for laptop PCs without a CD drive?
Thank you for your question. ELUSB V2.04 software is available as a download from OM-141 product page. Just scroll down under manuals and downloads there will a software download.
Date published: 2022-09-22
I see the data sheet says these work with Windows® XP/7 or 8 operating system. Will these work with Windows 10?
At the time it is only tested to work with operating systems up to Windows 8
Date published: 2022-10-18
Is there a way to delete the data on the logger after it is no longer needed?
Thank you for your question. When you imitate a new configuration it will reset the logger and delete the memory.
Date published: 2025-10-29
Are these NIST calibrated, because the product details do not mention that. If not, what would be the cost of getting it calibrated?
Thank you for your question. The OM-141 is not available with Nist Please consider OM-EL-USB-2-PLUS which is available with Nist. I have attached 2 links from our website with details and pricing.
https://www.omega.com/en-us/temperature-measurement/temperature-and-humidity-data-loggers/om-el-usb-1-series/p/OM-EL-USB-2-PLUS
https://www.omega.com/en-us//p/OM-EL-USB-2-PLUS-NIST
Date published: 2023-02-08
Would this device be compatible with any type of probe . we are currently loooking for a device to measure compost temperature and humidity via some kind of probe. Thank you !
Hello Marc
As long as it is one of the following thermocouple types: J, K, T, E, R, S, B, C or N
Also the probe will need either a standard round prong or mini blade type connector attached at the end so it can connect to the transmitter.
Date published: 2019-08-28