LCCD

Cellules de charge en forme de S protégées environnementalement IP67

IP67 Environmentally Protected S-Beam Load Cells
Modèles en stock
  • Environmentally Protected to IP67
  • All Stainless Steel for Industrial Environments
  • 5 Point Calibration with 59 kOhm Shunt Cal Data
  • Tension Calibration Standard
LCCD
À partir de C$ 1,067.11
Modèles en stock
IP67 Environmentally Protected S-Beam Load Cells LCCD LCCD
loading all models
Aperçu du produit
  • 5-Point Calibration 0%, 50%, 100%, 50%, 0%
  • Bridge Resistance 350 Ω
  • Cable Length 20 ft
  • Calibration Option 5 POINT NIST
  • Creep in 20 min 0.0003
  • Electrical Connection Cable
  • Electrical Output 3 mV/V
  • Enclosure Ratings IP67
  • Hysteresis 0.0005
  • Interchangeability 0.0025
  • Load Cell Type S-beam
  • Materials 17-4 PH Stainless Steel
  • Operating Temperature, Max 66 °C
  • Operating Temperature, Min -18 °C
  • Overload, Max 300% FS
  • Process Temperature, Max 66 °C
  • Process Temperature, Min -18 °C
  • Repeatability 0.0001
  • Safe Overload 150% FS
  • Series ID LCCD
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect 0.0015% rdg/°C
  • Thermal Zero Effect 0.0027% FS/°C
  • Wire Gauge 22 AWG
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error 0.01

Supported Applications

The Omega LCDC/LCMCD series consists of environmentally protected S-beam load cells designed for tension and compression applications. These units are engineered to measure force across a broad capacity envelope, ranging from 0-25 lb to 0-20,000 lb (0-10 kgf to 0-5000 kgf). The series is offered in both standard inch-pound models (LCDC) and metric kilogram-force models (LCMCD), providing a single solution for diverse measurement requirements.

Operating Conditions & Performance

The LCDC/LCMCD load cells operate within an ambient temperature range of -18 to 66°C (0 to 150°F). Constructed from 17-4 PH stainless steel, the series carries an IP67 enclosure rating for environmental protection. Electrical performance is defined by a bridge resistance of 350 Ω nominal and an output signal of 3.0 mV/V ±0.25%. The units require an excitation voltage of 10 Vdc (15 Vdc maximum).

Accuracy specifications documented for the series include:

  • Linearity: 0.03% FS
  • Hysteresis: ±0.05% FS
  • Repeatability: 0.01% FS
  • Creeep in 20 min: 0.03% FS
  • Zero Balance: 1% FS

The series supports a maximum safe load of 150% and an ultimate load limit of 300%. Thermal effects are specified as 0.0027% FS/°C for zero and 0.0015% rdg/°C for span.

Configuration Options

The series is available with a standard electrical connection consisting of a 6 m (20') 4-conductor shielded 22-gage wire PVC cable. Process connections feature A Threads on both ends, with thread sizes varying by capacity to match the load rating.

Capacity and Thread Configurations

The series supports multiple capacities paired with specific UNF-2B or metric threads:

  • Standard (lb): Capacities from 25 lb to 20,000 lb utilize thread sizes ranging from 1/4-28 UNF-2B up to 1-1/4-12 UNF-2B.
  • Metric (kgf): Capacities from 10 kgf to 5,000 kgf utilize thread sizes ranging from M8 x 1.25-6H up to M20 x 1.5-6H.

Accessories and Options

The series is compatible with various load button models (LBC) and rod end models (REC), which are sold separately. Specific accessory compatibility includes:

  • Load Button Models: LBC-014, LBC-038, LBC-012, LBC-034, LBC-100, MLBC-M8, MLBC-M12, MLBC-M20.
  • Rod End Models: REC-014M, REC-038M, REC-012M, REC-034M, REC-100M, REC-114M, MREC-M8M, MREC-M12M, MREC-M20M.

Each unit includes a 5-point NIST-traceable calibration certificate and shunt data. The series is compatible with meters such as the DP25B-S, DP41-S, and DPIS (noting that the DPIS meter is suitable for one-direction measurement only).

Key Product Differences

The LCDC/LCMCD series distinguishes between standard inch-pound models (LCDC) and metric kilogram-force models (LCMCD). Model numbers follow a specific guide: LCDC/LCMCD - <CAPACITY>. For example, an LCDC-1K denotes a 1000 lb capacity load cell, while LCMCD-100 indicates a 100 kgf capacity. Physical dimensions (H, W, T1, T2) vary by capacity and thread size as detailed in the specification tables.

Rated 4 out of 5 by from Great Load Cell Works well in all conditions, what we use it for it is located in the elements and works great all the time.
Date published: 2024-09-30
Rated 5 out of 5 by from Gets the job done! Excellent product. Easy to install and configure. Gives solid information feedback.
Date published: 2023-07-26
  • y_2026, m_9, d_1, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_LCCD-100, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Does this come with Rod Ends?

Asked by: sbprin
Dear Sbprin, No, does not come with RodEnds. Once you select your range please use the datasheet link and scroll down to see the rod ends: They will start with REC-XXX Or you can also email pressure@omega.com
Answered by: SAE ENGINEER GUY
Date published: 2020-06-16

Are CAD models available for this product?

Asked by: polymerTester
No CAD models of the LCCD are available
Answered by: Applicatrions Engineer JK
Date published: 2021-07-20

Does the LCCD-50 model have threaded holes at the ends, or is there a different model that allows for threaded ends?

Asked by: Josh_DAY
Thank you for your inquiry, The LCCD has Threaded holes on both ends, please see data sheet for thread sizes.
Answered by: rkent
Date published: 2021-10-14

What is the end cable type? Is there something that can be purchased that allows for easy connection to a NI DAQ machine?

Asked by: Josh_DAY
Thank you for your inquire The end of the cable is stripped leads. You can purchase converters that change the milli volt signal to a usb,voltage or current. Please contact the engineering department directly to discuss in detail.
Answered by: application engineer je
Date published: 2021-10-11
  • y_2026, m_9, d_1, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_LCCD-100, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 46ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration