Besoin d'aide? Appelez-nous: 1-800-663-4209
LCCD
Cellules de charge en forme de S protégées environnementalement IP67
IP67 Environmentally Protected S-Beam Load Cells
Modèles en stock
- Environmentally Protected to IP67
- All Stainless Steel for Industrial Environments
- 5 Point Calibration with 59 kOhm Shunt Cal Data
- Tension Calibration Standard
LCCD
À partir de
C$
1,067.11
Modèles en stock
Aperçu du produit
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Bridge Resistance 350 Ω
- Cable Length 20 ft
- Calibration Option 5 POINT NIST
- Creep in 20 min 0.0003
- Electrical Connection Cable
- Electrical Output 3 mV/V
- Enclosure Ratings IP67
- Hysteresis 0.0005
- Interchangeability 0.0025
- Load Cell Type S-beam
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 66 °C
- Operating Temperature, Min -18 °C
- Overload, Max 300% FS
- Process Temperature, Max 66 °C
- Process Temperature, Min -18 °C
- Repeatability 0.0001
- Safe Overload 150% FS
- Series ID LCCD
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect 0.0015% rdg/°C
- Thermal Zero Effect 0.0027% FS/°C
- Wire Gauge 22 AWG
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error 0.01
Supported Applications
The Omega LCDC/LCMCD series consists of environmentally protected S-beam load cells designed for tension and compression applications. These units are engineered to measure force across a broad capacity envelope, ranging from 0-25 lb to 0-20,000 lb (0-10 kgf to 0-5000 kgf). The series is offered in both standard inch-pound models (LCDC) and metric kilogram-force models (LCMCD), providing a single solution for diverse measurement requirements.
Operating Conditions & Performance
The LCDC/LCMCD load cells operate within an ambient temperature range of -18 to 66°C (0 to 150°F). Constructed from 17-4 PH stainless steel, the series carries an IP67 enclosure rating for environmental protection. Electrical performance is defined by a bridge resistance of 350 Ω nominal and an output signal of 3.0 mV/V ±0.25%. The units require an excitation voltage of 10 Vdc (15 Vdc maximum).
Accuracy specifications documented for the series include:
- Linearity: 0.03% FS
- Hysteresis: ±0.05% FS
- Repeatability: 0.01% FS
- Creeep in 20 min: 0.03% FS
- Zero Balance: 1% FS
The series supports a maximum safe load of 150% and an ultimate load limit of 300%. Thermal effects are specified as 0.0027% FS/°C for zero and 0.0015% rdg/°C for span.
Configuration Options
The series is available with a standard electrical connection consisting of a 6 m (20') 4-conductor shielded 22-gage wire PVC cable. Process connections feature A Threads on both ends, with thread sizes varying by capacity to match the load rating.
Capacity and Thread Configurations
The series supports multiple capacities paired with specific UNF-2B or metric threads:
- Standard (lb): Capacities from 25 lb to 20,000 lb utilize thread sizes ranging from 1/4-28 UNF-2B up to 1-1/4-12 UNF-2B.
- Metric (kgf): Capacities from 10 kgf to 5,000 kgf utilize thread sizes ranging from M8 x 1.25-6H up to M20 x 1.5-6H.
Accessories and Options
The series is compatible with various load button models (LBC) and rod end models (REC), which are sold separately. Specific accessory compatibility includes:
- Load Button Models: LBC-014, LBC-038, LBC-012, LBC-034, LBC-100, MLBC-M8, MLBC-M12, MLBC-M20.
- Rod End Models: REC-014M, REC-038M, REC-012M, REC-034M, REC-100M, REC-114M, MREC-M8M, MREC-M12M, MREC-M20M.
Each unit includes a 5-point NIST-traceable calibration certificate and shunt data. The series is compatible with meters such as the DP25B-S, DP41-S, and DPIS (noting that the DPIS meter is suitable for one-direction measurement only).
Key Product Differences
The LCDC/LCMCD series distinguishes between standard inch-pound models (LCDC) and metric kilogram-force models (LCMCD). Model numbers follow a specific guide: LCDC/LCMCD - <CAPACITY>. For example, an LCDC-1K denotes a 1000 lb capacity load cell, while LCMCD-100 indicates a 100 kgf capacity. Physical dimensions (H, W, T1, T2) vary by capacity and thread size as detailed in the specification tables.
Afficher les évaluations et les avis
Rated 4 out of
5
by
Dan E from
Great Load Cell
Works well in all conditions, what we use it for it is located in the elements and works great all the time.
Date published: 2024-09-30
Rated 5 out of
5
by
Luke S from
Gets the job done!
Excellent product. Easy to install and configure. Gives solid information feedback.
Date published: 2023-07-26
Does this come with Rod Ends?
Dear Sbprin,
No, does not come with RodEnds.
Once you select your range please use the datasheet link and scroll down to see the rod ends:
They will start with REC-XXX
Or you can also email pressure@omega.com
Date published: 2020-06-16
Are CAD models available for this product?
No CAD models of the LCCD are available
Date published: 2021-07-20
Does the LCCD-50 model have threaded holes at the ends, or is there a different model that allows for threaded ends?
Thank you for your inquiry, The LCCD has Threaded holes on both ends, please see data sheet for thread sizes.
Date published: 2021-10-14
What is the end cable type? Is there something that can be purchased that allows for easy connection to a NI DAQ machine?
Thank you for your inquire
The end of the cable is stripped leads. You can purchase converters that change the milli volt signal to a usb,voltage or current.
Please contact the engineering department directly to discuss in detail.
Date published: 2021-10-11