Need assistance? Call us: 1-800-663-4209
LC8400
Large 2.5 in to 3.13 in ID, Through-Hole, Compression Load Cells
Cellules de charge à compression, diamètre intérieur de 2,5 po à 3,13 po, à trou traversant
Models In Stock
- 5 Point NIST Traceable Calibration with
- 59 kOhm Shunt Cal Data
- 3.13, 4.00 and 4.50' OD Sizes
- Large I.D. Application
LC8400
From
C$
1,316.57
Models In Stock
Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Accuracy ± 0.5 %
- Cable Length 5 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Hysteresis ± 0.5%
- Input Resistance 360 Ω min
- Linearity ± 0.5%
- Load Cell Type Through Hole
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 121 °C
- Operating Temperature, Min -54 °C
- Output Resistance 350 ± 5 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.5%
- Safe Overload 150% FS
- Series ID LC8400
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.018% rdg/°C
- Thermal Zero Effect ± 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
Les capteurs de force annulaires des séries LC8313, LC8400 et LC8450 constituent une solution peu encombrante pour les applications nécessitant un grand trou traversant dans un espace limité. Grâce à leur construction et à leur conception robustes, ces capteurs de force sont idéaux pour des applications telles que les forces de charge sur de gros boulons ou d'autres applications de charge suspendue. Cette série, avec sa construction entièrement en acier inoxydable et sa protection environnementale, a prouvé sa fiabilité dans des applications industrielles difficiles.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
MBLTU from
Output cable
Shipped quickly. Used at our school and was easy to install
Date published: 2024-07-17
Rated 4 out of
5
by
AT Instrumentation from
Robust Load Cell Good for Industrial Applications
This load cell is very robust and suits industrial applications well. The performance of the cell is okay, but if finite measurements were desired, a more precise instrument would be needed.
Date published: 2023-01-23
The DP41-S mentioned above is out of stock. Is there another suitable display?
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Pressure Department Mon. – Fri. (HOURS 8:30AM - 5:00PM EST).
Date published: 2025-10-09
Could a model LC8313 be made with a 10' cable?
Thank you for your question?
The unit can be supplied with a 10 foot cable. This would make it non standard.
Please contact the sales group for pricing
Date published: 2019-06-27
How did you test it down to -54C, What liquid did you use to verify it at these temperatures, what happens beyound these temperatures? Unaccursy or complete failure?
Thank you for your inquiry. No testing was done, but it is the limiting temperature of the internal components. If the unit is used beyond the rated operating temperature, it will make readings unreliable and potentially damage the unit.
Hope this helps. Thank you
Date published: 2025-11-19
Do you offer a display unit we can use this load cell with? LC8400-213-200K
Thank you for your inquiry
The DP41-S is a good unit that will power and display the 200,000 counts
hope this was helpful.
Date published: 2021-03-26
For 8400 load cells greater than 10K, what are the dimensions of the loading surfaces? I need to machine mating adapters.
We can provide a control drawing with this information. Please contact Omega at pressure@omega.com and we will provide this drawing
Date published: 2023-02-11