Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FST200-Series

Thermal Dispersion Flow Switches for Liquids

Thermal Dispersion Flow Switches
Models In Stock
  • High Reliability — No Moving Parts
  • Very Low Flow Detection–Down to 0.04 FPS Liquids
  • Use in 1/8 through 12' Pipe or Tubing
  • SPST Relay Standard
FST200-Series
From C$ 434.30
Models In Stock
Thermal Dispersion Flow Switches FST200-Series FST200-Series
loading all models
Product Overview
  • Accuracy ± 5 %
  • Accuracy Detail ±5% of setpoint at constant temperature and flowrate
  • Additional Features 1  
  • Adjustments Potentiometer
  • Approvals CE
  • Approvals Note CE compliance: EN 61326 EMC EN 61010‐1 safety
  • Cable Length Note Max: 100 ft
  • Diameter 1.05 in
  • Electrical Connection 3/4 in NPT male Conduit with Cable
  • Enclosure Ratings IP65, NEMA Type 4X
  • Linear Flow Rate, Max 3 ft/s
  • Linear Flow Rate, Min 0.04 ft/s
  • Operating Pressure, Max 150 psi
  • Operating Pressure Note Maximum Fluid Pressure: PP or PVDF: 150 psi @ 25°C (77°F) derated @ 1.667 psi per °C above 25°C (77°F)
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -40 °C
  • Power Consumption 70 mA
  • Process Connection Size 3/4 in
  • Process Connection Type NPT Male
  • Process Temperature, Max 60 °C
  • Process Temperature, Min 0 °C
  • Response Time 10 sec
  • Response Time Note 10 sec after initial 30 sec warm up
  • Series ID FST200-Series
  • Supply Power Note 12 to 36 Vdc @ 70 mA
  • Supply Voltage 12 to 36 Vdc
  • Switch Rating 1 A
  • Switch Type SPST NO/NC, Selectable
  • Thermal Effects 0.5%/°C
  • Viscosity Range 1 to 300 cPs
  • Wire Gauge 22 AWG
Les vannes d'arrêt de débit OMEGA™ série FST-200 utilisent la technologie de dispersion thermique pour créer une méthode très précise et économique de détection du débit. Elles surveillent les fluides d'une densité comprise entre 0,4 et 1,2, d'une viscosité comprise entre 1 et 300 cp, et d'un débit pulsé compris entre 10 et 100 impulsions par minute. Les capteurs intègrent deux sondes de température, dont l'une est chauffée. Le débit du liquide réduit la température de la sonde chauffée, ce qui diminue la différence de température avec la sonde non chauffée. Les contrôleurs OMEGA LVCN-131 et LVCN-141 peuvent être facilement connectés pour effectuer diverses fonctions de contrôle.

Accessories

installation hardware

FLOW SWITCH FITTING PP
C$147.06 / each
0 In Stock

meters/controllers

Use with 0.10 - 6.53 GPM range, PVDF, 1/4 to 1/2 in pipe
C$228.85 / each
0 In Stock
Rated 1 out of 5 by from Great product! Unacceptable service I have one installed in a housing I made myself, and it has been working perfectly for about a year now.
Date published: 2017-05-12
Rated 3 out of 5 by from Flow Switch service replacements Sensors worked good, Many challenges to overcome for DC power supply, DC relay connections, and additions of DC to AC relays for proper operation
Date published: 2020-08-03
Rated 1 out of 5 by from Documentation sucks I guess these sensors connect themselves because there is ZERO info on the color code and wiring for NPN or PNP. No flow data either?????
Date published: 2019-09-26
  • y_2026, m_9, d_10, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_FST-211-SPST, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

How does one set the flow at which the device switches?

Asked by: DavidD
Thank you for your inquiry. There's a potentiometer on the flow switch which you can use to set the switch point. Full instructions to set a switch point can be found in the manual on page 12.
Answered by: AS Engineer
Date published: 2019-08-18

Can this unit be used in a wash down area; is the housing sealed against water ingress?

Asked by: BCB13
Thank you for your inquiry! These sensors have a NEMA 4X rating and should not have any issues in a washdown area.
Answered by: Application Engineer JM
Date published: 2025-08-21
  • y_2026, m_9, d_10, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_FST-211-SPST, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 11ms
  • QUESTIONS, PRODUCT
en-CA
fr
Save Configuration