Passer à la recherche Passer au contenu principal Passer à la navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

AQM-101

Formaldehyde Monitor and Data Logger

C$651.25 / each

Item# AQM-101

En stock

Délai de livraison (si non en stock) :6 jours

Spécifications du produit

<< Voir tous les modèles de produit
Brand
Fonctions supplémentaires 1 Wrong Location Environmental Monitor
Hauteur 110 mm
Humidité relative 10 to 90%
ID de série AQM-101-HCHO-Monitor
Interface de données USB
Largeur 108 mm
Longueur 28 mm
Mesure de la qualité de l'air 0 to 5 ppm
Mémoire 32,000 readings
Nombre de piles 4
Poids 165 g
Précision ± 5 % , + 0.03 ppm
Précision de l'humidité relative ± 5% RH
Précision de la température ± 0.1 °C
Remarque sur la mesure de la qualité de l'air 0.00 to 5.00 ppm @25ºC (77ºF), ambient pressure
Remarque sur la précision de l'humidité relative ±5% RH [at 25ºC (77ºF)]
Résolution 0.01 ppm
Résolution de température 0.1 °C
Taille et type de batterie Alkaline AAA
Temps de réponse < 30 sec (T90)
Température de stockage, max 70 °C
Température de stockage, min -40 °C
Température maximale du processus 50 °C
Température minimale du processus 0 °C
Type d'affichage LCD
Type de mesure HCHO ; température ; humidité relative
Type du capteur Stable Electrochemical
Valeur brute du poids 0.92
Pays d'origine Taiwan
Voir toutes les spécifications Montrer moins
Formaldehyde Monitor and Data Logger AQM-101 AQM-101
Rated 1 out of 5 by from Very Basic. Not very useful. Logging doesnt include TWA or STEL. Software very limited. Chart colors are terrible, Dark Blue background not a good choice and cant be changed. Changing line color makes it hard to see numbers on the side of the table. Each reading is a dot and not a continuous line making it hard to track. The only mode that shows up on the chart is Real-Time and it stops showing once it reaches the max 32000 points (doesnt rollover). If you choose RollOver mode, it does not display on the chart. If you download the data you have to do it every time it reaches 32000 points (every 8.8 hrs at 1 second scan rate) and then make your own chart/graph. This would be a decent monitor if they put a little effort into the functionality.
Date published: 2024-04-11
Rated 3 out of 5 by from Too Bad Ethanol Sets it Off Too! I bought these to detect formaldehyde outside of a fume hood in a lab space. Unfortunately it appears that this monitor detects the Methanol in the formaldehyde and not the formaldehyde itself. This is an issue because of the amount of Ethanol that we use of cleaning in our lab, these monitors were going crazy everytime Ethanol was sprayed and once the monitor was pegged it would take 30-40 minutes for it to return to normal levels. The monitor actually works really well but with our Ethanol use these are not practical in our lab.
Date published: 2022-03-28
Rated 4 out of 5 by from Reliable reading and reproducibility We purchased this model instead of other cheaper versions hoping to get an industrial level accuracy and reliability for the reading. We are quite happy on the reading stability and reproducibility so far. Repeated measurements comparing with fresh outdoor air has been done and this meter has proven to be solid. Battery life is also quite good. On the other side, you would need a Windows computer to be able to do logging. The unit does not log anything internally. The meter not only responds to Formaldehyde. It also responds to, say, acetone, tested so far. I would recommend Omega to provide a list of VOCs this meter is also responding to, and the associated corrections need to be applied. Or simply put the options into the firmware. It is not easy to tell if you are actually getting response from Formaldehyde or it could be some other VOCs being measured. In some limited scenarios, you could associate with the actual smell to distinguish the actual gas you are dealing with. For example, if you are using acetone to do some cleaning, you know the reading is from Acetone.
Date published: 2018-09-10
  • y_2026, m_4, d_13, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_AQM-101, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration