1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
OM-2041-Series
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product Models| Brand |
|
| AC Power Plug Type | N/A |
| Accuracy | ± 0.01 % |
| Accuracy Detail | Thermocouple: 100°C or More: (±0.1% of measuring value +0.3°C) , 100°C or Less: (±0.1% of measuring value +0.6°C), DC Voltage: (±0.1% of measuring value +0.2% of range); ±0.4°C (at ambient temperature 15 to 35°C); ±0.7°C (at ambient temp. -10 to 15, 35 to 50°C) |
| Approvals | CE |
| Approvals Note | EN-61326, Class B (battery operation) |
| Battery Size and Type | Alkaline AA |
| Data Interface | USB |
| Dimensions Note | 159 H x 70 W x 33 mm D excluding protrusions |
| Display Note | LCD with backlight Dot-matrix 128 x 64 dot (view area 41 x 29 mm), Operation key: 18-key including numeric key |
| Display Type | LCD |
| Enclosure Ratings | NEMA Type 3 |
| Height | 6.2 in |
| Input Control Signal | 0 to 5 Vdc |
| Input Current | 0 to 20 mA |
| Input Resistance | DC voltage inputs over 1 MΩ |
| Input Type | Thermocouple, Voltage, Current |
| Length | 1.3 in |
| Loop Resistance, Max | 100 Ω (burnout over upper limit) |
| Materials | Nylon |
| Memory | 10000 Records |
| Memory Note | Log Mode: 10,000 data records/channel Tag Mode: 5500 data records/channel |
| Mounting | Handheld |
| Operating Temperature, Max | 50 °C |
| Operating Temperature, Min | -10 °C |
| Relative Humidity | 10 to 80% RH no condensation |
| Sampling Rate | 1 sec to 24 hr |
| Sampling Rate Note | 1 second to 30 seconds (1 second steps) 1 minute to 24 hours (1 minute steps) Log Mode: Logging data per cycle (20 points) in log area Tag Mode: Logging data (20 points), then press the trigger in tag area |
| Series ID | OM-2041-Series |
| Supply Power Note | • 4 “AA” batteries or AC adaptor (100 to 240 Vac), • 500 hours or longer (at 25°C, 1-minute interval), • Backup log data, setting and clock by lithium battery with life of 5 years or longer (at 25°C). |
| Supply Power Type | Battery/AC |
| Supply Voltage | 100 to 240 Vac |
| Temperature Drift | ±0.01%/°C |
| Temperature Measurement Range | K: -200.0 to 1370.0°C,E: -200.0 to 700.0°C,J: -200 to 700.0°C,T: -200.0 to 400.0°C |
| Thermocouple Type | J, K, T, E |
| Weight | 10.5 oz |
| Width | 2.7 in |
| Withstand Voltage Note | 400 Vac |
| See All Specs | |
PDFs & Manuals
Accessories
accessories
sensors
General Purpose Thermocouple Probes With Miniature Plug Connector
C$112.70 / each
0 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$106.70 / each
7 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$106.70 / each
91 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$112.70 / each
12 In Stock
signal conditioners
Show Ratings & Reviews