Modèles en stock
- Fine Particulate Matter (PM2.5) Measurement
- Temperature and Humidity Measurements
- Health Index (0 to 9) Detection and Alarm
- PM2.5, Time Weighted Average Reading
HHTP21-Meter
Depuis
C$
771.48
Modèles en stock

L'aperçu du produit
- Status Control false
- Accuracy ± 10 % of reading ± 10 μg
- Air Quality Measurement 0 to 500 ug/m³
- Battery life 8 hr
- Battery Size and Type LR-6 AA
- Display Type LCD
- Height 75 mm
- Length 165 mm
- Memory 39 sets
- Number of Batteries 4
- Operating Humidity 0 to 95% RH
- Operating Temperature, Max 60 °C
- Operating Temperature, Min 0 °C
- Process Temperature, Max 60 °C
- Process Temperature, Min -20 °C
- Relative Humidity 1 to 99%
- Relative Humidity Accuracy ± 3% RH
- Relative Humidity Accuracy Note ±3% RH (at 25ºC,30 to 80% RH), ±5% RH (at 25ºC, 0 to 20% RH and 80 to 100% RH)
- Resolution 0.1 μg/m³
- Response Time Relative Humidity: 45 to 95% RH ≤ 1 min 95 to 45% RH ≤ 3 min;Temperature: 10°C/2 sec
- Sampling Rate 1 Hz (1 update/second)
- Sensor Type Photodiode Sensor, Precision Capacitance RH Sensor, Thermistor Sensor
- Storage Humidity, Max below 70% RH
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -10 °C
- Supply Power Note Four 1.5V LR-6 “AA” size batteries, AC adaptor (included)
- Temperature Accuracy ± 0.8 °C
- Temperature Resolution 0.1 °C
- Weight 380 g
- Width 93 mm
Particle pollution comes from many different type of sources. The HHTP21 Particulate meter and particle counter is ideal for monitoring particulate pollution in department stores, burning plants, petrochemical facilities, thermal power plants, restaurants, hospitals, mining facilities, metal refineries, commercial and public buildings. Fine particle (2.5 micrometers in diameter and smaller) are found in power plants, industrial processes, vehicle tailpipes, wood stoves, and wildfires. Coarse particles (between 2.5 and 10 micrometers) come from crushing and grinding operations, road dust, and some agricultural operations. Particle pollution is linked a number of health problems, including coughing, wheezing, reduced lung function, asthma attacks, heart attacks and strokes. It also is linked to early death.
Specifications
Measurement Range:
PM2.5: 0 to 500 µg/m3
Humidity: 1 to 99% RH
Temperature: -20 to 60°C (-4 to 140°F)
Resolution: 0.1 µg/m3, 1 ppm, 0.1% RH, 0.1°C, 0.1°F
Accuracy:
PM2.5: ±10% of reading ±10 µg
Temperature: ±0.8°C, ±1.5°F
Humidity: ±3% RH (at 25°C, 30 to 80% RH), ±5% RH (at 25°C, 0 to 20% RH and 80 to 100% RH)
Sensor Type:
PM2.5: Photodiode sensor
Humidity: Precision capacitance sensor
Temperature: Thermistor sensor
Response Time:
Humidity: 45 to 95% RH ≤ 1 min 95 to 45% RH = 3 min
Temperature: 10°C/2 sec.
Sampling Rate: 1 sample/second
Operating Temperature and Humidity: 0 to 60°C, below 95% RH
Storage Temperature and Humidity: -10 to 60°C, below 70% RH
Power Supply: Four 1.5V “AA†size batteries, AC adaptor (U.S. plug/included)
Battery Life: Approx. 8 hour
Dimensions: 165 L × 93 W × 75 mm D (6.5 × 3.7 × 3")
Weight: Approx. 380 g (13.4 oz)
Specifications
Measurement Range:
PM2.5: 0 to 500 µg/m3
Humidity: 1 to 99% RH
Temperature: -20 to 60°C (-4 to 140°F)
Resolution: 0.1 µg/m3, 1 ppm, 0.1% RH, 0.1°C, 0.1°F
Accuracy:
PM2.5: ±10% of reading ±10 µg
Temperature: ±0.8°C, ±1.5°F
Humidity: ±3% RH (at 25°C, 30 to 80% RH), ±5% RH (at 25°C, 0 to 20% RH and 80 to 100% RH)
Sensor Type:
PM2.5: Photodiode sensor
Humidity: Precision capacitance sensor
Temperature: Thermistor sensor
Response Time:
Humidity: 45 to 95% RH ≤ 1 min 95 to 45% RH = 3 min
Temperature: 10°C/2 sec.
Sampling Rate: 1 sample/second
Operating Temperature and Humidity: 0 to 60°C, below 95% RH
Storage Temperature and Humidity: -10 to 60°C, below 70% RH
Power Supply: Four 1.5V “AA†size batteries, AC adaptor (U.S. plug/included)
Battery Life: Approx. 8 hour
Dimensions: 165 L × 93 W × 75 mm D (6.5 × 3.7 × 3")
Weight: Approx. 380 g (13.4 oz)
Afficher les notes et les avis
Rated 4 out of
5
by
Bassey from
Easy to use and reliable
Bought the meter about a month ago for our laboratory in Nigeria. Meter is working excellently.
Date published: 2016-11-29
Rated 5 out of
5
by
Tony21 from
Great Product & Great Company to do business with
Great product and a Great Company to purchase from.
Date published: 2018-10-23
Is it possible to get the HHTP21 Air Quality Monitor re-calibrated? What is the recommended interval between calibrations?
Thanks for your question. Unfortunately no. We do not provide calibration services for this instrument. We usually recommend 1 year interval between calibrations.
Date published: 2023-07-06
Would this work for testing indoor air quality due to wild fire smoke?
Thank you for your inquiry. Yes, the HHTP21 can detect coarse and fine particles such as or from wildfires.
Date published: 2020-09-18
Is this unit capable of performing adequate particulate count for ISO 7 cleanroom?
Thanks for your question. Unfortunately, no this product is not rated for ISO 7 cleanroom applications. Please contact our Tech Support if you have any further questions.
Date published: 2019-05-13