Electronic Pressure Switch with OLED Display and Alarm OutputsPSW2100PSW2100
L'aperçu du produit
Accuracy
± 0.2 %
Deadband Type
Adjustable
Display
OLED Display
Electrical Connection
M12 4 pin Male
Enclosure Ratings
IP67, NEMA Type 6
Materials
316L Stainless Steel, Stainless Steel
Output Value
4 to 20 mA
Measurement Pressure Type
Gauge
Process Connection Type
NPT Male
Process Temperature, Max
120 °C
Process Temperature, Min
-40 °C
Stability
± 0.2% URL / 5 years
Storage Temperature, Max
85 °C
Storage Temperature, Min
-40 °C
Supply Power Note
≤1.44W(4-20mA+ transistor + OLED display @24Vdc)
Supply Voltage
12 to 30 Vdc
Transmission Distance
up to 1000 meters
Vibration
GB/T 1827.3/IEC61298-3 tests, <0.1% URL
Weight
0.4 kg
Omega’s PSW2100 electronic pressure switches feature a fully programmable digital interface with monosilicon sensor technology. Setup and programming is painless with the use of three keys and a premium, easy-to-read 1” wide 5-digit OLED display. Visibility is maximized with a display capable of rotating 350° and also with two LEDs providing visual alarms. With the rotation capabilties and a rugged, well-protected IP67 housing rating, this pressure switch is capable of high performance in a wide variety of environments and installation positions. These features coupled with high accuracy make this switch a premium, user-friendly option for pressure measurement and monitoring.
Thank you for your inquiry, the PSW2100-005C doesn’t have CRN’S .
Answered by: rkent
Date published: 2022-09-19
can it used on a helium supply system.
Asked by: Sparkie1
The wetted parts of this pressure transducer are all 316 Stainless Steel. It would be ok to use with Helium
Answered by: Applicatrions Engineer JK
Date published: 2021-11-10
What is the Emission and immunity to interference standard that applies to PSW2100 switch? For example, EN 61326 or NAMUR NE 21
Asked by: jfvanegasv
Thank you for your inquiry. Contacting manufacturing for information on which standard it conforms to. Will forward the information via email to you directly via email
Answered by: JK Applications Engineer
Date published: 2025-01-06
Will this switch work with a 4 pin M-12 connector?
Asked by: CSGPP
This pressure switch requires a 5-pin M12 female connector. It will not interface with a 4-pin M12.
Answered by: JK Applications Engineer
Date published: 2024-03-22
Just purchased a PSW2100-150C, I'm not getting a 4-20mA output, reads 21.1V open circuit and plugged into an measurement unit. Do I need to enable the output?
Signal connection diagram is incorrect, Pin 3 RET pin 5 SIG 2 SW2 4 SW1
Asked by: Mark123456
You should not have to enable the 4 to 20mA output. A wiring issue may be causing the problem. Reviewing the manual and will make corrections. Advise you contact us at pressure@omega.com with your contact information so we can respond directly with the resolution of this issue
Answered by: Applicatrions Engineer JK
Date published: 2022-11-30
Is this suitable for liquid measurement? The water we are measuring is contaminated with mercury.
Asked by: rebeler1
The Process Connection Material for the PSW2100-400C is 316L SS, this material is suitable for liquids
Answered by: rkent
Date published: 2021-05-19
Is this product capable of external visual warning/monitoring? As in output wired to 2-3 LEDs a couple feet away that read under pressure, good pressure, and/or overpressure? If not, could you point me in the direction of a product that does. Thank you.
Asked by: Greg14
The two on board transistor output can be wired to switch the power being used to drive the unit to also drive external alarm devices.