PRTXD

Digital Temperature Transmitter

Modèles en stock
  • Two-Wire Transmitter
  • 4 to 20 mA Output
  • 3 1/2 Digit Display
  • RTD Probe Included, Available with 4' or 12' Immersion Lengths, Fixed Length or Spring Loaded for Thermomell Use
PRTXD
Depuis C$ 932.58
Modèles en stock
Digital Temperature Transmitter PRTXD PRTXD
loading all models
L'aperçu du produit
  • Précision ± 0.1 %
  • Détail de la précision ±0.1% of span plus max sensor error of ±0.3°C at 0°C or ±1.1°C at 150°C
  • Display Type 4.5 Digit LCD
  • Electrical Connection Cable
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP66, NEMA Type 4X
  • Housing Material ABS,Polycarbonate
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -20 °C
  • Sensor Length 12 in
  • Sheath Material 316 Stainless Steel
  • Storage Temperature, Max 95 °C
  • Storage Temperature, Min -40 °C
  • Supply Voltage 8 to 32 Vdc
  • Temperature Measurement Range -50 to 200 °C
  • Temperature Resolution 0.1 °C
  • Weight 1 lb
  • Wire Gauge 22 AWG
The PRTXD Series are two-wire transmitters that provide a 4 to 20 mA signal representing temperature. The units include a 3 1/2 digit display and the RTD sensor. The NEMA 4X (IP66) housing protects the electronics. Units are available with 4 inch or 12 inch fixed length or spring loaded RTD probes. Spring loaded RTD probes provide good thermal contact when used in thermowells.
Rated 5 out of 5 by from Hi Temp Temerature Transmitter Nice to find one with that high of a temperature tolerance.
Date published: 2021-12-21
  • y_2025, m_9, d_14, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_PRTXD-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

What is the pressure rating of the probe when used without a thermowell?

Asked by: TerryD
Hi TerryD, Thank you for the request. We do not provide a pressure rating on this product due to the temperatures the probe may be exposed to. Best regards, OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-12-12

Can the 4-20 mA output be scaled on this transmitter. ie could you scale your 4-20 for 0 - 50 degrees?

Asked by: Mack
Hi Mack, Thank you for the inquiry. Yes, the scale can be modified to 0 to 50 degrees. Manual describes the configuration steps. Best regards OMEGA
Answered by: AENorwalk
Date published: 2020-02-21
  • y_2025, m_9, d_15, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_PRTXD-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration