1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
CYC325-Series
Cryogenic Dual Channel Digital Benchtop Temperature Controller
Contrôleur de température numérique de paillasse à double canal cryogénique- Operates Down to 1.2 K with Appropriate Sensors
- 2 Sensor Inputs
- Supports Diode, RTD, and Thermocouple Sensors
- Sensor Excitation (Current Reversal Eliminates Thermal EMF Errors for Resistance Sensors)
CYC325-Series
From
C$
13,038.47
Product Overview
- A/D Conversion 24-bit
- Accuracy Selectable
-
Accuracy Detail
PTC RTD (0 to 500 Ω : Range) : ± 0.004 Ω, ± 0.01 % of rdg
PTC RTD (0 to 5000 Ω : Range) : ± 0.004 Ω, ± 0.02 % of rdg
NTC RTD (0 to 7500 Ω : Range) : ± 0.1 Ω, ± 0.04 % of rdg
Thermocouple (± 25 mV) : ± 1 µV,± 0.05 % of rdg
Thermocouple (± 50 mV) : ± 1 µV,± 0.05 % of rdg
- Approvals CE Mark
- Baud Rate 9600 to 57600
-
Control Characteristics
PID Control Settings:
- Proportional (Gain): 0 to 1000 with 0.1 setting resolution
- Integral (Reset): 1 to 1000 (1000/s) with 0.1 setting resolution
- Derivative (Rate): 1 to 200% with 1% resolution
Manual Output: 0 to 100% with 0.01% setting resolution
Zone Control: 10 temperature zones with P, I, D, manual heater out, and heater range
Setpoint Ramping: 0.1 K/min to 100 K/min
Safety Limits: Curve temperature, power up heater off, short circuit protection
- Control Output Heater
- Control Type Manual Heater Output, Open Loop, PID Control
- Data Interface RS232
- Digital Connector Type 9 pin Sub-D
- Display Annunciators Autotune, Control input, Remote
- Display Measuring Units °C, K, mV, V
- Display Size 5.5 mm Digits
- Display Type LCD
-
Display Type Note
Display: 2-line, 20-character, liquid crystal display with 5.5 mm (0.216”) character height
Display Update Rate: 2 rdg/s
Other Displays: Setpoint, heater range, and heater output; user selected
- Electrical Connection Ceramic Isothermal Block
- Filter Averages 2 to 64 input readings
- Form factor Benchtop
- Front Panel Display Readings 1 to 4
- Heater Output Display Percentage of full power or current
- Heater Output Resolution 0.01
- Height 89 mm
- Input Type Thermocouple, RTD, Thermistor
- Input Type Note Temperature, sensor units Input Configuration: Each input is factory configured for either diode/RTD or thermocouple
- Interface Features IEEE-488 Interface Features: SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0, E1
- Isolation Sensor inputs optically isolated from other circuits but not each other
- Keypad 20-key membrane, numeric and specific functions
- Length 368 mm
- Loops Control Loops : 2
- Measurement Type Temperature
- Number of Control Outputs 2
- Number of Inputs 2
- Operating Temperature, Max 35 °C
- Operating Temperature, Min 15 °C
- Output Detail 2 Heater output
- Output Signal None
- Power Consumption 6 W
- Resolution Sensor dependent, refer to input specifications table
- RTD Type 4-lead differential With 6-Pin DIN Connector
- Sampling Rate 10 Hz (10 updates/second)
- Sampling Rate Note To 10 rdg/s on each input
-
Sensor Input Configuration
Measurement Type: 4-lead differential
Excitation: Constant current with current reversal for RTDs Supported
Sensors: Diodes, silicon, GaAlAs; RTDs, 100 Ω Platinum, 1000 Ω Platinum, germanium, carbon-glass, CernoxTM, and RoxTM Standard Curves: CY7 and CY670, PT-100, PT-1000, RX-102A, RX-202A
Input Connector: 6-pin DIN
- Sensor Units Display Resolution Sensor dependent up to 5 digits
- Series ID CYC325-Series
- Setpoint Setting Resolution Same as display resolution (actual resolution is sensor dependent)
- Settable Parameters Curve Entry, Keypad Lock-out
- Software Support LabVIEWTM driver; consult factory for availability
- Supply Power Note Standard 120 Vac, optional 240 Vac, 6%, -10%, 50 or 60 Hz, 85 VA
- Supply Power Type AC
- Supply Voltage 100 to 240 Vac
- Temp Display Resolution 0.001° from 0 to 99.999°, 0.01° from 100 to 999.99°, 0.1° above 1000°
- Tuning Autotune, PID, PID zones
- Update Rate, Max 10 rdg/s on each input (except 5 rdg/s on input A when configured as thermocouple)
- Weight 4 kg
- Width 216 mm
Description
Le contrôleur de température à double canal de la série CY325 est capable de prendre en charge presque tous les capteurs de température à diode, RTD ou thermocouple. Deux boucles de contrôle PID indépendantes avec des sorties de chauffage de 25 et 2 Ware sont configurées pour piloter une charge de 50 ou 25 à pour une flexibilité de contrôle optimale. Conçue dans un souci de facilité d'utilisation, de fonctionnalité et de valeur, la série CYC325 est idéale pour les applications générales de mesure et de contrôle de la température en laboratoire et dans l'industrie.
PDFs & Manuals
Accessories
accessories
cables
1 m (3.3 ft long) IEEE-488 (GPIB) computer interface cable assembly
C$606.99 / each
0 In Stock
installation hardware
Rack mount kit for mounting one 1/2 rack temperature controller in 482.60 mm (19 in) rack, 90 mm (3.5 in) high
C$754.65 / each
0 In Stock
Rack mount kit for mounting two 1/2 rack temperature controllers in 482.60 mm (19 in) rack, 135 mm (5.25 in) high
C$835.30 / each
0 In Stock