1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
OM-CP-OCTPRO-Logger
Enregistreur de données portable programmable à 8 canaux - Écran tactile
Modèles en stock
- L'interface tactile permet une configuration facile sans PC ni logiciel
- Mesure simultanément la température, le courant, la tension et le pouls sur 8 canaux
- Compatible avec les thermocouples, les RTD, les thermistances et les capteurs à sortie de tension
- La mémoire intégrée stocke les données avec affichage en temps réel et sortie USB téléchargeable
OM-CP-OCTPRO-Logger
À partir de
C$
1,768.20
Modèles en stock
Aperçu du produit
- Type de prise d'alimentation CA N/A
- Précision ± 0.1 %
- Précision Précision du courant : ±0,024 mA Précision de la tension : ±0,1 mV, ±0,01 V Précision du thermistor : ±0,50 % Précision du RTD : ±0,1 °C Précision du thermocouple : J, K, T, E, N : ±0,5 °C R, S, B : ±2,0 °C
- Taille et type de batterie 3,7 V Li-ion
- Étalonnage L'étalonnage en usine est recommandé annuellement
- Interface de données USB
- Remarque sur les Dimensions 6,65 po x 4,40 po x 1,41 po (168,9 mm x 111,8 mm x 35,8 mm) Enregistreur de données uniquement
- Remarque sur l'affichage Écran tactile LCD : écran tactile capacitif LCD de 5 pouces.
- Type d'affichage Écran LCD
- Caractéristiques nominales du boîtier IP20
- Échelle d'entrée de fréquence 0 à 25 kHz
- Hauteur 6.65 in
- Impédance d'entrée Impédance d'entrée courant : 30Ω, Impédance d'entrée tension : 1 GΩ, Impédance d'entrée fréquence : 58 kΩ
- Signal de commande d'entrée Entrée millivolt : -100 à 2450 mV Entrée en volts : -0,5 V à 12,0 V
- Courant d'entrée -5 à 50 mA
- Type d'entrée Thermocouple ; RTD ; Thermistance ; Courant ; Tension ; Numérique
- Longueur 1.41 in
- Matériaux Polycarbonate
- Mémoire 1 000 000 ou 5 000 000 de lectures
- Remarque sur la mémoire 1 000 000 ou 5 000 000 de lectures
- Montage Portatif, de table ou montage mural
- Remarque sur l'entrée d'impulsions 0 à 4 000 000 000 impulsions
- Humidité relative 0 à 95 % HR sans condensation
- Résolution 0,1 °C
- Remarque sur la résolution Résolution du courant : 0,0001 mA Résolution de la tension : 0,0001 mV, 0,0001 V Résolution RTD : 0,01 °C Résolution thermistance : 0,01 °C Résolution thermocouple : J, K, T, E, N : 0,1 °C R, S, B : 0,5 °C
- Fréquence d'échantillonnage 4 kHz
- ID de série OM-CP-OCTPRO-Logger
- Modes de démarrage Démarrage différé, Démarrage immédiat
- Approvisionnement Remarque • Batterie rechargeable Lithium Ion 3,7 V, • Échantillonnage continu à l'écran : 9 heures ; Mode veille : 100 heures
- Type d'approvisionnement électrique USB
- Plage de mesure de la température J : -200 à 760 °C ; K : -270 à 1370 °C ; T : -270 à 400 °C ; E : -270 à 980 °C ;R : -50 à 1760 °C ; S : -50 à 1760 °C ; N : -270 à 1300 °C ; B : 50 à 1820 °C ;RTD : -200 à 850 °C ; TH 2252 Ω ; 10 kΩ : -25 à 150 °C
- Type de thermocouple J ; K ; T ; E ; N ; R ; S ; B
- Poids 1.3 lb
- Largeur 4.4 in
- Tableau de câblage/connecteurs RTD 2 et 4 fils
L'enregistreur OM-CP-OCTPRO est une solution tout-en-un pour les applications qui nécessitent une analyse immédiate. Équipé de huit canaux d'entrée, l'OCTPRO peut mesurer simultanément le courant, la tension, la température et le pouls, fournissant aux utilisateurs des données en temps réel à tout moment. Aucun PC n'est nécessaire, les utilisateurs peuvent visualiser toutes les données sous forme de tableaux ou de graphiques sur l'écran tactile couleur de 5 pouces.
OM-CP-OCTPRO Logger Highlight Sa polyvalence fait de l'OM-CP-OCTPRO le compagnon idéal des ingénieurs industriels, des professionnels de l'assurance qualité, des responsables de la conformité ou des techniciens automobiles. L'OM-CP-OCTPRO est très facile à utiliser et à configurer grâce à son écran graphique tactile capacitif intégré.
Applications
- Afficheur process
- Études sur l'efficacité des machines
- Applications polyvalentes en laboratoire et en R&D
Configuration de l'OM-CP-OCTPRO
I
Configuration du canal OM-CP-OCTPRO
Applications
- Afficheur process
- Études sur l'efficacité des machines
- Applications polyvalentes en laboratoire et en R&D
I
PDF & Manuels
Logiciels & Pilotes
Accessoires
accessories
Afficher les évaluations et les avis
Rated 4 out of
5
by
Grill Engineer from
Temperature Testing
Overall impression is good! It is super easy to use, I did not even require the manual to get up and testing in 5 minutes. My only complaints are battery life for long data logging tests (you can leave plugged in to wall outlet just wish the battery lasted longer), the plug in connectors are a little difficult to install and remove, I wish I could view all channels at the same time on the graph, I wish I could adjust the scale of the graph and finally I wish it could record more channels.
Date published: 2020-07-29
Rated 1 out of
5
by
loon027 from
Completely broken after a few uses
the analog board blew out according to an error message on the display after using only a few times. It was measuring fine but ended up just stopping and I haven't bee able to start it back up since then. It appears to be a $1000 broken piece of equipment. I'll see what Omega does to help fix this situation.
Date published: 2021-04-21
Rated 3 out of
5
by
roy wood from
Logger impressions after initial setup and use
This device is very simple and functional, but has several shortcomings. The touchscreen sometimes is very insensitive and other times double hits, but it is useable. The data graph is very basic with very limited scaling and only 2 channels displayed. This device is adequate, but was expecting amazing at this price point.
Date published: 2020-11-11
Rated 4 out of
5
by
Gerald43 from
Field Engineer
I bought this about two months ago and overall have been happy with it. There were a few times I had an error with programming when turning it on but was able to quickly fix the issue by just resetting it and have been able to log several different parameters and get the results I needed to. It coupled well with some of the pressure and temperature sensor we had available and the data and time stamping seemed accurate and easy to export. I think that this is a good versatile data logger for monitoring industrial issues.
Date published: 2020-05-22
Rated 5 out of
5
by
ChE John from
So easy to use!!!
Let me preface my review by letting you know that I am an engineer employed at a large and very well-known chemical company. I purchased this data logger a few weeks ago to log pressure in my plant's fire water piping system. I have used many different data loggers in the past, but this one is by far the best and easiest I have ever used. My only complaint is that this data logger does not have a built-in power supply; however, considering how small this data logger is in comparison to others with an interactive visual display, how can I really complain.
Date published: 2019-03-06
Rated 1 out of
5
by
Aaron K from
Tons of promise wrecked by poor UI and a buggy OS
We needed a product to use on the road for some basic logging - some 4-wire RTD's and some analog channels. This seemed like a great way to avoid headaches for temporary setups. We've got a deep well of trust for Omega, having used Omega stuff for years and years. So this was a shoe-in.
Out of the box, all was well. The interface draws a lot from modern smartphone conventions, which makes it super intuitive to figure out - I was logging 2 minutes after I opened it up.
In the field though, things began to fall apart.
During setup it would occasionally freeze up and need a power cycle. Fine, normal, but the power cycling takes a very long time (2-3 minutes at least) and the device doesn't tell you if it's turning off, turning on, if you've pressed the button long enough, etc. This was surprisingly frustrating.
Many selections made on the touchscreen (such as reading interval) feature a "poke and pray" scrolling list, which would be too hard to use even on the newest phones.
The screen itself has to be the poorest capacitive screen I've ever used. It almost feels like one of those old resisitive ones.
Data cannot be removed during a logging session. Not a big deal, unless combined with the last and largest issue...
Getting the thing to recognize a USB stick (including the one it comes with) is madness. Reboot, reboot with it plugged in, try a different stick, take it back to your PC and format it, reboot again, and MAYBE this time it will recognize it.
It's an excellent toy if you want to mess around. But if data is equal to dollars, stay far away from this product.
Date published: 2020-01-24
Rated 1 out of
5
by
Nick1 from
Do not buy
This datalogger is the most frustrating logger I have ever setup. Half the time, the settings do not save and you have to start from scratch, while the other half the screen randomly chooses different options that either cancel your setup or just start the logging without your parameters. When you finally do get a setup to run, you can't access the other saved data on the machine so you're stuck waiting until the test is complete. There have been days where I've spent hours trying to get the buggy screen to simply start a test only for it to fail or exit out just before I finish. Do not purchase this logger under any circumstances. Find one that doesn't have a touch screen from the early 2000s.
Date published: 2025-10-13
Rated 4 out of
5
by
Robby M from
Multi-channel configurable input data logger.
Excellent multi-channel data logger for the price. The unit is easy to configure and has good battery life. It would be nice if the unit had an internal loop power supply but this is easily overcome by obtaining a 24 VDC power supply (for loop power) and 24vdc to usb adapter to charge / power the device.
Date published: 2025-02-26
Can we connect strain gauge sensors or SG quarter bridge with this logger. And LVDT with 80mv/v could be connected with this logger?
Hello, this logger will not work with quarter bridge strain gauge or 80mv/v LVDT. We do not offer an off the shelf logger for quarter bridge strain gauge circuits. You will need to complete your bridge first.
Date published: 2025-06-05
The OM-CP-OCTPRO won't turn back on, how can I trouble shoot it? I have tried changing the charging cable. Any suggestions as to why it won't turn back on?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Date published: 2021-12-09
What are the power requirements to keep the unit continuously powered? The battery life is far too short for a semi-permanent installation.
Assuming that I don't have a 120 VAC plug in handy inside of the controller where I'd need to install the logger though, I'd need to provide power another way. I assume that it's expecting 5V on the USB circuit, but how much amperage will it draw? I can provide 5V more easily than 120V, but I'd still need to know the load.
Date published: 2022-11-23
What is the sample rate range?
Copied and pasted from the spec page:
All channels will use the same reading rate. Reading rates will be capped at 4 Hz when a temperature channel is selected.
Date published: 2024-11-13
There is one issue that continually comes up, in that it doesn't recognize a USB stick when inserted, so it is difficult to transfer the data off of the unit. Is there a workaround or firmware update available?
Thank you for your question. Please note that the USB drive should not be inserted until the OM-CP-OCTPRO is fully booted. If the USB drive is inserted before the OM-CP-OCTPRO is started, the drive will not be recognized. Please wait until the device is running, and then insert the USB drive. If you have further issues please e-mail DAS Engr-DAS@OMEGA.COM.
Date published: 2022-07-05
Channel 9 details? The manual is not clear on how ch 9 is connected to the system, just says "Port 9 serves as an alarm output". Are there any other details available (voltage, current limits, etc.)? Need to determine what, if anything, can be connected.
Thank you for your question. Please e-mail this request to our Data Acquisition Engr Dept- DAS@OMEGA.COM
Date published: 2023-03-28
How often is calibration recommended? Aside from standards is there a manufacturer time frame for this?
Thank you for your question. With all of our loggers, we recommend calibrating every year. However, this is not any sort of official specification or requirement; this is just our general recommendation. How often a user has the device calibrated will depend on their specific accuracy needs, any regulatory requirements they need to conform to, etc. So, ultimately, how often they calibrate the device will be their decision.
Date published: 2021-03-11
I need a downloadable data sheet for this product. Where can this be found? Thanks!
Hello
Please send request to das@omega.com
Thank you!
Date published: 2020-02-12