Passer à la recherche Passer au contenu principal Passer à la navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

OM-CP-OCTPRO

Enregistreur de données portable programmable à huit canaux

Choisir une variante

Nombre de canaux

C$1 768.20 / each

Item# OM-CP-OCTPRO

En stock

Délai de livraison (si non en stock) :6 semaines

Spécifications du produit

<< Voir tous les modèles de produit
Marque
Approvisionnement Remarque • Batterie rechargeable Lithium Ion 3,7 V, • Échantillonnage continu à l'écran : 9 heures ; Mode veille : 100 heures
Caractéristiques nominales du boîtier IP20
Courant d'entrée -5 à 50 mA
Fréquence d'échantillonnage 4 kHz
Hauteur 6.65 in
Humidité relative 0 à 95 % HR sans condensation
ID de série OM-CP-OCTPRO-Logger
Impédance d'entrée Impédance d'entrée courant : 30Ω, Impédance d'entrée tension : 1 GΩ, Impédance d'entrée fréquence : 58 kΩ
Interface de données USB
Largeur 4.4 in
Longueur 1.41 in
Matériaux Polycarbonate
Modes de démarrage Démarrage différé, Démarrage immédiat
Montage Portatif, de table ou montage mural
Mémoire 1 000 000 ou 5 000 000 de lectures
Nombre de canaux 8
Plage de mesure de la température J : -200 à 760 °C ; K : -270 à 1370 °C ; T : -270 à 400 °C ; E : -270 à 980 °C ;R : -50 à 1760 °C ; S : -50 à 1760 °C ; N : -270 à 1300 °C ; B : 50 à 1820 °C ;RTD : -200 à 850 °C ; TH 2252 Ω ; 10 kΩ : -25 à 150 °C
Poids 1.3 lb
Précision Précision du courant : ±0,024 mA Précision de la tension : ±0,1 mV, ±0,01 V Précision du thermistor : ±0,50 % Précision du RTD : ±0,1 °C Précision du thermocouple : J, K, T, E, N : ±0,5 °C R, S, B : ±2,0 °C
Remarque sur l'affichage Écran tactile LCD : écran tactile capacitif LCD de 5 pouces.
Remarque sur l'entrée d'impulsions 0 à 4 000 000 000 impulsions
Remarque sur la mémoire 1 000 000 ou 5 000 000 de lectures
Remarque sur la résolution Résolution du courant : 0,0001 mA Résolution de la tension : 0,0001 mV, 0,0001 V Résolution RTD : 0,01 °C Résolution thermistance : 0,01 °C Résolution thermocouple : J, K, T, E, N : 0,1 °C R, S, B : 0,5 °C
Remarque sur les Dimensions 6,65 po x 4,40 po x 1,41 po (168,9 mm x 111,8 mm x 35,8 mm) Enregistreur de données uniquement
Résolution 0,1 °C
Signal de commande d'entrée Entrée millivolt : -100 à 2450 mV Entrée en volts : -0,5 V à 12,0 V
Tableau de câblage/connecteurs RTD 2 et 4 fils
Taille et type de batterie 3,7 V Li-ion
Type d'affichage Écran LCD
Type d'approvisionnement électrique USB
Type d'entrée Thermocouple ; RTD ; Thermistance ; Courant ; Tension ; Numérique
Type de prise d'alimentation CA N/A
Type de thermocouple J ; K ; T ; E ; N ; R ; S ; B
Valeur brute du poids 3.6
Échelle d'entrée de fréquence 0 à 25 kHz
Étalonnage L'étalonnage en usine est recommandé annuellement
Pays d'origine United States
Voir toutes les spécifications Montrer moins
Enregistreur de données portable programmable à huit canaux OM-CP-OCTPRO OM-CP-OCTPRO

Accessoires

Prise d’alimentation pour AUSTRALIE
C$80.23 / each
4 En stock
Fiche d'alimentation pour CHINE
C$80.23 / each
4 En stock
Fiche d’alimentation pour UE
C$80.23 / each
0 En stock
Prise d’alimentation pour le Japon
C$80.23 / each
3 En stock
Prise d'alimentation pour le Royaume-Uni
C$80.23 / each
6 En stock
Rated 4 out of 5 by from Temperature Testing Overall impression is good! It is super easy to use, I did not even require the manual to get up and testing in 5 minutes. My only complaints are battery life for long data logging tests (you can leave plugged in to wall outlet just wish the battery lasted longer), the plug in connectors are a little difficult to install and remove, I wish I could view all channels at the same time on the graph, I wish I could adjust the scale of the graph and finally I wish it could record more channels.
Date published: 2020-07-29
Rated 1 out of 5 by from Completely broken after a few uses the analog board blew out according to an error message on the display after using only a few times. It was measuring fine but ended up just stopping and I haven't bee able to start it back up since then. It appears to be a $1000 broken piece of equipment. I'll see what Omega does to help fix this situation.
Date published: 2021-04-21
Rated 3 out of 5 by from Logger impressions after initial setup and use This device is very simple and functional, but has several shortcomings. The touchscreen sometimes is very insensitive and other times double hits, but it is useable. The data graph is very basic with very limited scaling and only 2 channels displayed. This device is adequate, but was expecting amazing at this price point.
Date published: 2020-11-11
Rated 4 out of 5 by from Field Engineer I bought this about two months ago and overall have been happy with it. There were a few times I had an error with programming when turning it on but was able to quickly fix the issue by just resetting it and have been able to log several different parameters and get the results I needed to. It coupled well with some of the pressure and temperature sensor we had available and the data and time stamping seemed accurate and easy to export. I think that this is a good versatile data logger for monitoring industrial issues.
Date published: 2020-05-22
Rated 5 out of 5 by from So easy to use!!! Let me preface my review by letting you know that I am an engineer employed at a large and very well-known chemical company. I purchased this data logger a few weeks ago to log pressure in my plant's fire water piping system. I have used many different data loggers in the past, but this one is by far the best and easiest I have ever used. My only complaint is that this data logger does not have a built-in power supply; however, considering how small this data logger is in comparison to others with an interactive visual display, how can I really complain.
Date published: 2019-03-06
Rated 1 out of 5 by from Tons of promise wrecked by poor UI and a buggy OS We needed a product to use on the road for some basic logging - some 4-wire RTD's and some analog channels. This seemed like a great way to avoid headaches for temporary setups. We've got a deep well of trust for Omega, having used Omega stuff for years and years. So this was a shoe-in. Out of the box, all was well. The interface draws a lot from modern smartphone conventions, which makes it super intuitive to figure out - I was logging 2 minutes after I opened it up. In the field though, things began to fall apart. During setup it would occasionally freeze up and need a power cycle. Fine, normal, but the power cycling takes a very long time (2-3 minutes at least) and the device doesn't tell you if it's turning off, turning on, if you've pressed the button long enough, etc. This was surprisingly frustrating. Many selections made on the touchscreen (such as reading interval) feature a "poke and pray" scrolling list, which would be too hard to use even on the newest phones. The screen itself has to be the poorest capacitive screen I've ever used. It almost feels like one of those old resisitive ones. Data cannot be removed during a logging session. Not a big deal, unless combined with the last and largest issue... Getting the thing to recognize a USB stick (including the one it comes with) is madness. Reboot, reboot with it plugged in, try a different stick, take it back to your PC and format it, reboot again, and MAYBE this time it will recognize it. It's an excellent toy if you want to mess around. But if data is equal to dollars, stay far away from this product.
Date published: 2020-01-24
Rated 1 out of 5 by from Do not buy This datalogger is the most frustrating logger I have ever setup. Half the time, the settings do not save and you have to start from scratch, while the other half the screen randomly chooses different options that either cancel your setup or just start the logging without your parameters. When you finally do get a setup to run, you can't access the other saved data on the machine so you're stuck waiting until the test is complete. There have been days where I've spent hours trying to get the buggy screen to simply start a test only for it to fail or exit out just before I finish. Do not purchase this logger under any circumstances. Find one that doesn't have a touch screen from the early 2000s.
Date published: 2025-10-13
Rated 4 out of 5 by from Multi-channel configurable input data logger. Excellent multi-channel data logger for the price. The unit is easy to configure and has good battery life. It would be nice if the unit had an internal loop power supply but this is easily overcome by obtaining a 24 VDC power supply (for loop power) and 24vdc to usb adapter to charge / power the device.
Date published: 2025-02-26
  • y_2026, m_4, d_29, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.43
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_11
  • loc_en_CA, sid_OM-CP-OCTPRO, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration