  • Compliance CE
  • Enclosure Ratings None
  • Media Compatibility Air, Argon, Carbon dioxide, Helium, Nitrogen, Non-Corrosive Dry Gases
  • Mounting Orientation Not Position Sensitive
  • Operating Temperature, Max 140 °F
  • Measurement Pressure, Min 25 psi
  • Measurement Pressure Type Gauge
  • Process Connection Size 1/4 in
  • Process Connection Type NPT Female
  • Repeatability ± 5 psi
  • Set Point Adjustment Internal Screw
  • Switch Note 2 each SPST snap action, normally closed (NC), 20 A @ 120 VAC, 12 A @ 240 VAC, 9.6 A @ 240 VAC (3 phase), 8.6 A @ 32 VDC, 3.1 A @ 120 VDC, 1.6 A @ 240 VDC. 1.5 HP @ 120 VAC, 2 HP @ 240 VAC, 3 HP @ 240 VAC (3 phase), 0.25 HP @ 32/120/240 VDC.
  • Switch Rating 20 A @ 120 Vac, 12 A @ 240 Vac, 9.6 A @ 240 Vac (3 phase), 8.6 A @ 32 Vdc, 3.1 A @ 120 Vdc, 1.6 A @ 240 Vdc.ac
  • Switch Type SPST Snap, NC

The Series CX Compressor Pressure Switches are designed with a 20 amp normally closed SPST switch for direct control of pumps and motors. The set point and deadband are both easily adjustable via screw terminals inside the cover. For ease of installation, the switches come with a 1/4" female NPT process connection or the optional 4-port connection block on the CX-4 models. Besides making installation easier, one of the other ports can be used to install a pressure gage. Plus, these switches can be mounted in any orientation.

These units are perfect for regulating tank pressure on small air compressors. The CX series switches come with an unloader valve, which prevents compressors from starting under load. They also come with an auto/off disconnect lever for manually cutting off the load. When the lever is in the off position, there is a test button inside the housing that can be pushed to turn on the load.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 22ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration