Besoin d'aide? Appelez-nous: 1-800-663-4209
TSW-TD
Interrupteurs de température à action rapide NPT 1/2 po
- Interruttore a scatto di alta qualità
- Contatti da 5 Amp
- Resistente a urti e vibrazioni
- Filettatura di montaggio 1/2 NPT
TSW-TD
À partir de
C$
126.22
Aperçu du produit
- Accuratezza ± 3 °C (± 5,4 °F)
- Lunghezza cavo 457 mm
- Collegamento elettrico Cavi
- Caratteristiche elettriche 5 A a 250 V CA
- Isteresi media -11,1 °C
- Temperatura di esercizio, max 325 °F
- Temperatura di esercizio minima 0 °F
- Diametro della sonda 14.2 mm
- Lunghezza della sonda 16 mm
- Dimensioni attacco al processo 1/2 pollice
- Tipo di attacco al processo NPT maschio
- ID serie TSW-TD
- Tipo di setpoint Fisso
- Attivazione interruttore In aumento
- Tipo di interruttore SPDT NO
- Tipo di sensore di temperatura Soffietto
Description
Les interrupteurs thermiques à action instantanée de haute qualité de la série TSW-TD d'Omega sont parfaits pour les applications qui nécessitent une solution économique pour simplifier le contrôle de la température. Tous les thermostats s'activent en cas d'augmentation de la température et résistent aux chocs et aux vibrations. La série TSW-TD offre un large choix de valeurs de température préréglées.Afficher les évaluations et les avis
Rated 5 out of
5
by
Adolfo from
Good choice
Well constructed and seems to be a solid probe. Time somentime to get it delivered as the company doesn’t keep inventory.
Date published: 2024-05-14
Hi, Do your TSW-TD sensors come with the mounting nut? Thanks
The TSW-TD series does not include the mounting nut as they are typically screwed into the 1/2 Female NPT on the process equipment.
Date published: 2026-05-07
I bought one (TSW-TD-1c-250R/WL) for the purpose of regulating temperature in a heated stainless cabinet. I installed it and the temperature went high to 170 degrees C; it did not shut off. Is this intended for installing in a liquid piping?
Hi Martin
This switch will activate on rising temperature at 250 F. It both NO and NC contacts. NO, black to red, will read closed when above the set point. The NC, black to blue, will read open above the set point.
This is designed for liquid applications. Perhaps the unit is mounted where and air-pocket forms in the pipe.
Best regards
OMEGA
Date published: 2021-02-03