Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

OM-CP-XRTDTemp-Series

X-Series - Multi Channel RTD Temperature Loggers

Models In Stock
  • ± 0.04 °C Calibrated Accuracy
  • Real time Operation
  • Up to 4 Hz Reading Rate
  • Pushbutton or Programmable Start Time
OM-CP-XRTDTemp-Series
From $ 981.80
Models In Stock
X-Series - Multi Channel RTD Temperature Loggers OM-CP-XRTDTemp-Series OM-CP-XRTDTemp-Series
loading all models
Product Overview
  • Calibration Digital calibration through software
  • Data Interface WiFi
  • Data Interface Note USB-A to micro USB cable (included); 460,800 baud
  • Electrical Connection Screw Terminal
  • Enclosure Aluminium
  • Form factor Benchtop
  • LED Indicators 1 per channel and 2 status LEDs
  • Length 65.6 mm
  • Operating Humidity 0 to 95% RH
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Process Temperature, Max 850 °C
  • Process Temperature, Min -200 °C
  • Process Temperature Note 18.5 Ω to 390.5 Ω -200 °C to +850 °C (-328 °F to +1562 °F) (Probe Dependent)
  • Real Time Recording May be used with PC to monitor and record data in real time
  • Samples,Max 2800000
  • Sampling Rate 1 day
  • Sampling Rate Note 4 Hz up to 1 reading every 24 hours
  • Software Compatibility Windows XP SP3/7/8/10
  • Start Modes Adjustable Delay Start, Immediate Start
  • Supply Power Type Battery
  • Temperature Resolution 0.001 °C
  • Temperature Resolution Note 0.0001 Ω 0.001 °C (0.0018 °F) (Probe Dependent)
  • Temperature Sensor Type RTD
  • Time Accuracy ± 1 minute/month
  • Width 184.2 mm

The new OM-CP-RTDTempX Series consists of 4, 8, 12 and 16-channel RTD Temperature data logger with a reading rate of up to 4 Hz. X-Series devices ship with a standard USB-A to Micro USB cable for use with free OM-CP PC based software. The X-series has a high memory capacity and increased download speed compared to previous generations of product.

To maximize memory capacity, users can enable or disable channels. For easy identification, each channel can be named with up to a ten digit title.

Using the OM-CP Data Logger Software, starting, stopping and downloading from the OM-CP-RTDTempX Series data loggers is simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.

* Temperature specs based on ideal 100 Ω Pt RTD compliant with IEC 751 (1983) and ITS-90, 5000 Ω FSR (accuracy based on 36 inch lead wire RTD with4 wire configuration)

** Calibrated accuracies based on standard Omega calibrations for 0 Ω to 200 Ω range.

Accessories

consumables

Replacement 9V lithium battery
$55.90
4 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Is there a part number for ordering additional screw terminal connectors that can be plugged into the OM-CP-OCTRTDTEMP-A? Can you provide information how we can obtain replacements?

Asked by: 0475536342
Thank you for your question. OM-CP-CONNECTOR-4 is replacement connector for logger. https://www.dwyeromega.com/en-us/replacement-4-position-terminal-block-connecto/p/OM-CP-CONNECTOR-4
Answered by: PVLENGR
Date published: 2025-06-27

Could I read data directly to a .csv file via USB?

Asked by: Nazarii HRZ
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: PVLENG
Date published: 2024-11-19

Follow up to the question about reading temperature information on demand: can I read temperatures into LabVIEW in real time using the GUI software?

Asked by: Jantzi
Thank you for your question. There is no Labview support for the logger just provided software.
Answered by: Application Engineer PV
Date published: 2021-12-03

Does it work Win10?

Asked by: cbyFS
Thank you for your question. Yes it does work with Win 10.
Answered by: Application Engineer PV
Date published: 2021-04-29

We would like to connect our OM-CP-OCTRTDTEMP-A to a SAPC-RTD-4-100-A-120 RTD. Does the RTD come with screw terminals that will plug into the logger? If not can we purchase new screw terminals for the logger?

Asked by: 0475536342
Thank you for your question. The RTD has stripped leads, and the logger is provided with screw terminals to accommodate stripped leads.
Answered by: PVLENG
Date published: 2025-06-26

Does it work under vacuum state? in the vacuum chamber?

Asked by: Mr Oh
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2023-06-12

Can I put the entire logger in a vacuum chamber? I want to measure temperature in a vacuum enivroment

Asked by: moty
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: PVENG
Date published: 2025-01-28

Does it work with PT-1000 RTD's?

Asked by: Alfred
Thank you for your question. The logger only supports PT100 rtd's.
Answered by: Application Engineer PV
Date published: 2023-05-23
  • y_2025, m_8, d_30, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_16
  • loc_en_US, sid_OM-CP-OCTRTDTEMP-A2, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 39ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration