Need assistance? Call us: 1-800-663-4209
VT-110
VT-110: B&K Vibro Compact Vibration Velocity Transmitter with 4-20mA Output
Models In Stock
- Vibration Velocity Output 4-20mA loop powered
- Additional dynamic signal output - 100mV/g
- High quality with glass sealed M12 connector
- Compact size with superior “annular shear technology”
VT-110
From
$
475.69
Models In Stock
Product Overview
- Additional Features 1 100mV/g Additional dynamic signal output
- Applications Assembly Line, Casing Vibration, Compressor Control, Power Generation, Power Plants & Boilers, Pump Control, Shaft Vibrations
- Approvals CE
- Cable Length 5 m
- Capacitance 70 pF
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP67
- Frequency Note 3 Hz to 1 kHz
- Ground Isolated Case
- Isolation 100 MΩ
- Loop Resistance, Max (Vdc power -10V)/20mA
- Mounting UNF Tapped Hole
- Operating Temperature, Max 120 °C
- Operating Temperature, Min -55 °C
- Operating Temperature Note Temperature operating_x000D_ • Loop current max. 10 mA -55…+120 °C (-65…+250 °F)_x000D_ • Loop current max. 20 mA -55 …+90 °C (-65…+212 °F)
- Output Detail Analog output_x000D_ • Analog output 4…20 mA, loop powered, proportional to vibration velocity mm/s rms_x000D_ • No vibration 4 mA ±5%_x000D_ • Full scale 20 mA ±5%
- Overload Capacity 2500 g peak
- Protection Overvoltage : Yes,Reverse polarity : Yes
- Sensitivity Range 100 mV/g ± 30 %
- Series ID VT-110
- Supply Voltage 10 to 30 Vdc
- Tolerance ± 30 %
- Vibration 250 g peak
Supported Applications
The VT-110 is a hermetically sealed, 4-20 mA loop-powered industrial vibration velocity transmitter designed for monitoring vibration in harsh industrial environments. It measures vibration velocity and is intended for continuous machinery condition monitoring where a rugged, compact transmitter is required.
The transmitter interfaces directly with PLCs, DCS, or 4-20 mA monitors and complies with ISO 10816 standards, making it straightforward to integrate into existing plant instrumentation. Its compact size allows installation in tight spaces, and it features a glass-sealed M12 axial connector with dual case isolation and an IP 67 enclosure rating for reliable service in demanding conditions.
The unit mounts using a machine thread M8 x 1.25 and provides both an analog loop output and a dynamic signal output (buffer) for connection to external analyzers. Installation and operation require qualified personnel.
Operating Conditions & Performance
The primary output is an analog 4-20 mA, loop powered, proportional to vibration velocity in mm/s rms. It reads 4 mA ±5% at no vibration and 20 mA ±5% at full scale. A separate dynamic output (buffer) provides a sensitivity of 100 mV/g with a tolerance of ± 30 %. Output linearity is specified to a maximum of ±1%.
The transmitter is loop powered from a 10...30 VDC supply, and the maximum load resistance is defined by RI Max=(Vdc power -10V)/20mA. The mounted resonant frequency is 25 kHz.
Operating temperature depends on the loop current drawn:
- Loop current max. 10 mA: -55...+120 °C
- Loop current max. 20 mA: -55...+90 °C
The enclosure carries an IP 67 rating. The transmitter withstands 250 g peak continuous vibration and a 2,500 g peak shock acceleration limit, and it is CE marked.
Configuration Options
All VT-110 transmitters share the M12 axial connector and 4-20 mA loop-powered architecture; the variants differ in two selectable parameters encoded in the model number.
Frequency range is set by the first code position:
- /01: 3...1,000 Hz
- /02: 10...1,000 Hz
Measuring range is set by the second code position:
- /020: 0...20 mm/s rms
- /050: 0...50.8 mm/s rms
The /01 code selects the wider 3...1,000 Hz frequency range, while the higher-range measuring code raises full scale from 20 mm/s to 50.8 mm/s for machines with larger vibration amplitudes.
Key Product Differences
Model numbers follow the structure VT-110/<frequency_range_code>/<measuring_range_code>/CE/0, for example VT-110/01/020/CE/0. The four ordering combinations, all using the M12 axial connector, are:
- VT-110/01/020/CE/0 — 3...1,000 Hz / 20 mm/s
- VT-110/02/020/CE/0 — 10...1,000 Hz / 20 mm/s
- VT-110/01/050/CE/0 — 3...1,000 Hz / 50.8 mm/s
- VT-110/02/050/CE/0 — 10...1,000 Hz / 50.8 mm/s
Two connecting cables are available as accessories: the AC-1405/0050 standard overmolded cable with M12 connector, 5m length, and the AC-1406/0050 angle overmolded cable with M12 connector, 5m length.