OMB-DAQ-56

USB Data Acquisition Modules for Thermocouples Process Signals

$2,680.88 / each

Item# OMB-DAQ-56

Product Specs

<< See all Product Models
Brand
A/D Conversion 22-Bit A/D
Accuracy ± 0.5 °C
Analog I/O Note Analog Input Note: Analog Specifications;Each channel is configurable for single-ended or differential, Volts, or thermocouple inputs;Thermocouple Accuracy;In very slow mode, 22 bit resolution, includes cold junction compensation error;J (±1.1°C), K (±1.2°C), T (±1.1°C); E (±1.0°C), R (±2.5°C), S (±2.6°C), B (±3.3°C), N (±1.5°C);Cold Junction Compensation Accuracy: (±0.5°C),;Over-Voltage Protection: ±45 V relative to analog Lo;AC Common Mode Rejection: >120 dB @ 60 Hz;Channel-to-Channel Crosstalk: <-120 dB (DC to 100 Hz);;Accuracy;OMB-DAQ-55/56: 0.015% of reading +0.002% of range (exclusive of noise);Input Resistance: >10 M Ohm (SE), >20 M Ohm (DE);Bias Current: <1 nA (0-35°C)
Bandwidth DC to 1 MHz
CMRR >120 dB @ 60 Hz
Commodity Code 8471.80.1000
Configuration Parameters Open-Collector Driver, Schmitt-Trigger Input, User-Configurable Input/Output
Data Interface Ethernet
DepthValue 12.1
Digital I/O Note Digital Output Maximum Switch Voltage:0 to +15 Vdc (20 V for <1 minute) Maximum Switch Current: 150 mA/output continuous, 500 mA/output peak (<100 µs),150 mA total continuous (per bank of 8 outputs) Output Resistance: 10 Ohms max;Cross talk: <-120 dB (DC to 100 Hz);Sink Current: 150 mA
Digital Input Digital: Low <1.3 Vdc
ECCN 3A992.a
GrossWeightValue 1.5
Height 45 mm
HeightUoM IN
HeightValue 2.6
Input Configuration Connected Software
Input Resistance >10 MΩ (SE), >20 MΩ (DE)
Input Type Thermocouple, Voltage
Isolation 500V from PC
Length 182 mm
NetWeightValue 1.5
Number of Channels, Input Analog: 10 DE, 20 SE, Frquency/Pulse: 4, Digital: 16
Number of Channels, Output Digital:16
OkForExport true
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
Output Resistance 10 Ω
Output Signal Digital
Pull-up Resistor 27 KΩ to 5V for Switch or Relay Sensing
Relative Humidity 0 to 95% RH non-condensing
Sampling Rate 80 Hz (80 updates/second)
Series ID OMB-DAQ55-Series
Supply Power Note Powered from USB, or from external 6 to 16 Vdc when used with a buspowered hub
Supply Power Type DC/USB
Supply Voltage 6 to 16 Vdc
Taxonomy Level 1 MGI
Taxonomy Level 2 DA
Taxonomy Level 3 BC
Taxonomy Level 4 PO
Voltage Measurement Range ±20V, -10 to 20V, ±10V, ±5V, ±4V, ±2.5V, ±2V, ±1.25V, ±1V, ±625 mV, ±500 mV, ±312 mV, ±250 mV , ±156 mV , ±125 mV, ±62 mV, ±31 mV, Differential, Single ended
WeightUoM LB
Width 92 mm
WidthValue 8.9
Country of Origin Hungary
See All Specs Show Less
USB Data Acquisition Modules for Thermocouples Process Signals OMB-DAQ-56 OMB-DAQ-56

Accessories

TERMINAL BLOCK
$54.87 / each
3 In Stock
DASYLab Data Acquisition System
$2,324.11 / each
0 In Stock
Rated 5 out of 5 by from ULTIMATE FOR RELIABILITY AND ACCURACY !!! RECOMMENDED FOR THERMOCOUPLE AND LOAD CELL MONITORING
Date published: 2017-12-24
  • y_2026, m_1, d_29, h_17
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OMB-DAQ-56, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration