1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
RD1000-RD2000-RD3000-Series
Touch Screen Paperless Recorders with Expandable I/O
Models In Stock
- Color TFT Touch Screen Display: 4.3', 5.6' and 12.1'
- Expandable Inputs and Outputs via Plug and Play I/O Cards: RD1000/2000 Series–4 Slots RD3000 Series–16 Slots
- Analog Inputs: RD1000 Series–Up to 6, RD2000 Series–Up to 24, RD3000 Series–Up to 48
- User Friendly with Bar Graph, Numerical, Vertical or Horizontal Trend Display
RD1000-RD2000-RD3000-Series
From
$
3,075.57
Models In Stock
Product Overview
- Accuracy ± 0.05 %
- Accuracy Detail Voltage and Current: ±0.05%, Thermoocouple: (J, K, T, E): ±1˚C, (N, L, U, P, W5, W3, LR, A1, A2, A3, M, E, B, R): ±2˚C, RTD: ±0.4˚C (CU10: ±1.0˚C)
- Altitude,Max 2000 m
- Burnout Current 10 µA
- CMRR 120 dB
- Configuration ARM Cortex-A8, 1 GHz
- Connection Note 2 Ports (One front, One back)
- Data Interface Ethernet, Modbus
- Depth Behind Panel 171 mm
- Dielectric Strength 2300 Vac, 50/60 Hz for 1 minute between power terminal and earth
- Display Type LCD
- Enclosure Ratings IP20, IP65
- Features 19 languages including English, Japanese, Chinese (simplified, traditional), French, German, Spanish, Swedish, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Brazil Portuguese and Czech
- Input Current ± 26 mA
- Input Note Sensor Lead Resistance Effect: Thermocouple: 0.32 ppm of reading/Ω, 3-Wire RTD: 2.6˚C/Ω of resistance difference of two leads (based on ˚C measurement temperature for Pt100), 2-Wire RTD: 2.6˚C/Ω of resistance sum of two leads (based on ˚C measurement temperature for Pt100); RTD Input: ±20V, Thermocouple and Voltage Input: ±65V, Current (mA) Input: ±10V
- Input Type Thermocouple, RTD, Voltage, Current
- Input Voltage ± 60 mVdc, ± 200 mVdc, ± 1 Vdc, ± 2 Vdc, ± 6 Vdc, ± 20 Vdc, ± 50 Vdc, 0.4 to 2 Vdc, 1 to 5 Vdc
- Insulation Resistance 20 MΩ @ 500 Vdc
- Isolation 1500 Vac at 50/60 Hz for 1 minute
- Keypad Functions Start/Stop Recording and turn off Display only (for quick re-start), Does not turn off Power to the unit
- Length 189 mm
- Measurement Type Universal
- Memory 256 MB Samples on 128 MB Flash Card
- NMRR 55 dB
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Relative Humidity 20 to 90% RH
- Relative Humidity Note 20 to 90% RH (noncondensing), maximum relative humidity of 90% RH is for ambient temperature up to 38˚C (100˚F) decreasing linearly to 50% RH at 50˚C
- RTD Type 2-, 3- or 4-wire RTD
- Sampling Rate 10 Hz (10 updates/second)
- Sensor Break Detection Sensor opened for thermocouple, RTD and mV inputs; below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs; Within 1 second for thermocouple, RTD and mV inputs; 0.1 second for 4 to 20 mA and 1 to 5V inputs
- Shock Resistance 30m/s² (3g) for Operation, 20 g for Transportation
- Software Standard Software supplied for Historical data viewing and Configuration, Optional: Data Acquisition Studio Software, OS:Windows XP/Vista/7/8
- Storage Temperature, Max 70 °C
- Storage Temperature, Min -30 °C
- Supply Power Note 90 to 250 Vac, 47 to 63 Hz,52 VA, 26 W max; 11 to 36 Vdc, 26 VA, 26 W max (optional)
- Supply Power Type AC
- Supply Voltage 90 to 250 Vac
- Thermal Effects ±0.1 µV ±15 ppm of reading for all inputs except mA, ±30 ppm of reading for mA input
- Thermocouple Type J, K, T, E, N, R, S, B, C, W5, W3, L, U, P, A1, A2, A3, M, LR
- Vibration Resistance 10 to 55 Hz, 10 m/s² for 2 hours
The RD1000/2000/3000 Series paperless recorders offer real time display of data in a variety of formats on a high resolution TFT touch screen display. The user friendly unit with plug and play cards can easily be set to monitor, record, and evaluate any application. The user can access data on the screen, as well as from a remote site via the standard Ethernet, Web Server or optional RS232/422/485 serial interface. The historical data may be stored in a flash ROM, compact flash card, or collected in a remote host PC for evaluation and print out. The units compact size saves space and minimizes depth required behind the panel.
Expandable Input and Output Cards
Each recorder is equipped with rear expansion slots (RD1000/RD2000 Series has 4 slots, RD3000 Series has 16 slots) which work flexibly with the following plug and play I/O cards:
Analog Input Cards (RD1000-3AI & RD1000-6AI): These two cards are used for 3 or 6-channel analog inputs. Each input is isolated from each other to avoid noise and to ensure stable measurement.
Relay Output Card (RD1000-6R):
Each card includes 6 alarm relays. Contacts are rated 5 A/240 Vac
Digital Input Card (RD1000-6DI):
Each card includes 6 channels. Logic Low: -5V minimum, 0.8V maximum, Logic High: 3.5V minimum, 24V maximum
Combination Relay Output and Digital Input Card (RD1000-3R-3DI): Each card includes 3 digital Inputs and 3 relay outputs. For digital inputs, Logic Low: -5V minimum, 0.8V maximum, Logic High: -3.5V minimum, 24V maximum. For relay outputs, the contacts are rated 5 A/240 Vac.
Analog Output Card (RD1000- 6AO): Each card includes 6 channels. They are used for 4 to 20 mA, 0 to 20 mA current output, 0 to 5 V, 1 to 5 V, 0 to 10 Vdc voltage output.
Communication
The standard communication interface is Ethernet with protocol IEEE 802.3 † “ 10/100 Base T. RS232/422/485 serial communications is optional.
Expandable Input and Output Cards
Each recorder is equipped with rear expansion slots (RD1000/RD2000 Series has 4 slots, RD3000 Series has 16 slots) which work flexibly with the following plug and play I/O cards:
Analog Input Cards (RD1000-3AI & RD1000-6AI): These two cards are used for 3 or 6-channel analog inputs. Each input is isolated from each other to avoid noise and to ensure stable measurement.
Relay Output Card (RD1000-6R):
Each card includes 6 alarm relays. Contacts are rated 5 A/240 Vac
Digital Input Card (RD1000-6DI):
Each card includes 6 channels. Logic Low: -5V minimum, 0.8V maximum, Logic High: 3.5V minimum, 24V maximum
Combination Relay Output and Digital Input Card (RD1000-3R-3DI): Each card includes 3 digital Inputs and 3 relay outputs. For digital inputs, Logic Low: -5V minimum, 0.8V maximum, Logic High: -3.5V minimum, 24V maximum. For relay outputs, the contacts are rated 5 A/240 Vac.
Analog Output Card (RD1000- 6AO): Each card includes 6 channels. They are used for 4 to 20 mA, 0 to 20 mA current output, 0 to 5 V, 1 to 5 V, 0 to 10 Vdc voltage output.
Communication
The standard communication interface is Ethernet with protocol IEEE 802.3 † “ 10/100 Base T. RS232/422/485 serial communications is optional.
PDFs & Manuals
Accessories
accessories
Anemometers for Spare 2 GB SD memory card
$10.25
0 In Stock
Show Ratings & Reviews