TXUN-ST-FM-Series-Tx
2-Wire Programmable Transmitter with Universal Input
Models In Stock
TXUN-ST-FM-Series-Tx
From
$
223.08
Models In Stock

Product Overview
- Accuracy ± 0.05 %
- Accuracy Detail ≤ ±0.05% of span
- ADC Resolution 20 bit
- Approvals "Authority Requirements: EMC: 2014/30/EU RoHS: 2011/65/EU EAC: TR-CU 020/2011"
- Cable Resistance 5 Ω
- Calibration TXUN-KIT Communication Tool Kit
- Calibration Temperature, Max 28 °C
- Calibration Temperature, Min 20 °C
- Cold Junction Compensation < ±1.0°C
- DAC Resolution 16 bit
- Diameter 44 mm
- Drop 7.2 Vdc
- Electrical Connection Screw Terminal
- Electrical Output 4 to 20 mA
- EMC Standard NAMUR NE 21
- Enclosure Ratings IP00, IP68
- Height 20.2 mm
- Humidity Range Up to 95% non-condensing
- Input Control Signal -12 to 800 mV
- Input Resistance 10 MΩ
- Input Type Thermocouple, RTD, Resistance, Voltage
- Isolation 1500 V
- Offset 50% of selected max. value
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Output Detail Min. Signal Range: 16 mA NAMUR NE43 Upscale/Downscale: 23 mA/3.5 mA
- Output Load ≤ (Vsupply - 7.2)/0.023 Ω
- Power Dissipation 25 mW to 0.8 W
- Probe Length 0 mm
- Programmable Functions Loop Link and HART
- Response Time 1 to 60 sec
- RTD Type Ni100,Pt100
- Sensor Break Detection 3.5 to 23 mA
- Sensor Current 0.2 mA
- Sheath Material N/A
- Signal/Noise Ratio > 60 dB
- Stability ≤ 0.01% of span/100 Ω (Load Stability)
- Supply Power Effects < 0.005% of span/Vdc
- Supply Power Type DC
- Supply Voltage 7.2 to 35 Vdc
- Temperature Coefficient ≤ ±0.01%/°C
- Temperature Input Range N/A
- Thermocouple Type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
- Update Rate, Max 440 ms
- Vibration IEC 60068-2-6;2 to 25 Hz: ±1.6 mm;25 to 100 Hz: ±4 g
- Warm Up Time 5 min
- Weight 50 g
- Wiring/Connector Table 2-, 3-, or 4-Wire
Application
• Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
• Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.• Amplification of a bipolar mV signal to a standard 4 to 20 mA current signal.
Technical Characteristics
• Within a few seconds the user can program PR5331A to measure temperatures within all ranges defined by the norms.
• The RTD and resistance inputs have cable compensation for 2/3 and 4-wire connection.
• A continuous check of vital stored data for safety reasons.
PDFs & Manuals
Software & Drivers
Accessories
accessories
Show Ratings & Reviews
Rated 5 out of
5
by
Mayor Stacy from
GREAT SERVICE
I appreciate the quality service that provided a quality product.
Date published: 2024-08-29
What is the size and thread of the 2 mounting screws. Thank you.
Thank you for your inquiry Engr416. Due to the complexity of your question, please send an email to temp@omega.com and one of our engineers will assist you in finding this information.
Date published: 2022-08-24
Can I program the output of the 4-20ma to equal 0 degrees F to 300 degrees F. i.e. 4ma=0F and 20ma=300F with a 100ohm RTD 32-492F range.
You can scale the PT100 RTD to any values within the sensors range using the TXUN-KIT programming module sold as an accessory.
Date published: 2021-12-03