Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

M12probes

Thermocouple Probes with Mounting Threads and M12 Connectors

Models In Stock
  • Type J with 304SS probe in 1/4" or 6mm diameter
  • Type K with Inconel 600 probe in 1/8", 1/4", 3mm, or 6mm diameter
  • Single or Dual Element Configurations
  • Variety of Lengths and Mounting Threads
M12probes
From $ 67.76
Models In Stock
Thermocouple Probes with Mounting Threads and M12 Connectors M12probes M12probes
loading all models
Product Overview
  • Connector Temperature, Max 85 °C
  • Connector Temperature, Min -50 °C
  • Electrical Connection M12 4 pin Male
  • Process Connection Type NPT Male
  • Process Temperature, Min 0 °C
  • Temperature Sensor Type Thermocouple
  • Vibration Vibration Tested at 3g’s Between 5 and 500 Hz for 3 Hours in the Axial and Transverse Axes

Note: These Sensors Require an M12 Extension Cable to Connect the Sensor to Your Instrumentation.

Omega's M12 Thermocouple probes are a convenient way to measure the temperature in your process. These thermocouple probes are available as Type K thermocouples with Inconel 600 sheaths, or as Type J thermocouples with 304 Stainless Steel Sheaths. Standard probe sizes include 1/4" & 1/8" diameter probes 6, 9, 12, 18 and 24" long, and 3mm & 6mm diameter probes 200, 350 and 500mm long. These thermocouples can also be provided in other lengths.

With a variety of standard mounting threads, these probes can be easily configured to match your specific requirements. Fractionally sized 1/4" and 1/8" diameter probes are available with 1/2"NPT, 3/8"NPT, 1/4"NPT or with no mounting threads. Metric sized 3mm and 6mm diameter probes are available with M8x1, M10x1 or with no mounting threads. The non-threaded versions of the sensor can be used as-is or mounted into your process using one of Omega's line of Compression Fittings.

For use in thermowells, the M12-TC-SL version of this sensor is the preferred solution. The M12-TC-SL design includes a non-threaded M12TC style probe with a self-gripping spring and 1/2NPT threaded fitting to insure that the probe will contact the bottom of the thermowell bore without damaging the sensor. This insures that the sensor length will always be a perfect fit for your thermowell. See the M12-TC-SL page for additional information.

The thermocouple compensated M12 connector offers a quick and reliable method for connecting this sensor to your instrumentation. The M12 connector on these sensors is wired in accordance with the pin out shown in the accompanying figure. This pin out matches the wiring provided on Omega's Molded M12 Thermocouple extension Cables so that the IEC or ANSI color code is maintained between the sensor and your instrumentation. A selection of Omega's M12 Extension Cables are included in the ordering table below.


View the Thermocouple Accuracy and Color Code charts

Accessories

signal conditioners

Compact Analog Current or Voltage to IO Link Convertor
$180.99
100 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What is the time constant for these, J and K?

Asked by: muchtoohard
Thank you for the inquiry, Please use following charts for time constant values; https://www.omega.com/en-us/resources/thermocouples-response-time Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-03-14

M12KIN-M3-U-200-E CAD models?

Asked by: ABRU
We do not provide with CAD drawings of our products. They are considered proprietary information. Thank you.
Answered by: Application Engineer
Date published: 2021-04-01

What is the pinout for the M12KIN-1/8-U-2-B model and how do the pin outputs read a temperature?

Asked by: Eleanor
Hi Eleanor, Thank you for the inquiry. The M12 pins are set up so that pin 3 is (-) and pin 2 is (+). The pins provide connection point for the electrical signal. Following link may help you with detail; https://assets.omega.com/pdf/cable-and-wire/cable-assemblies/thermocouple-and-rtd-cable-assemblies/M12CM.pdf Best regards, OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-02-24
  • y_2025, m_10, d_10, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_M12JSS-1-4-U-12-B, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration