CL543B

Calibrator for Thermocouple and RTDs (PT100)

Choose a Variant

Operating Temperature, Max

$2,520.77

Item# CL543B

In Stock

Lead Time (If not in stock): 5 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 Read and Source Signals
Alerts Red LED displays OVERLOAD or out of range conditions
Battery life 50 hr, low battery warning with less than 1 hr operation left
Cold Junction Sensor ≤± 0.01% °/ ° from ambient temperature ( °C or °F)
Display Type LCD
Display Type Note High contrast graphic Liquid Crystal Display. LED backlighting for use in low lit areas.
Height 41 mm
Length 143 mm
Operating Temperature, Max 60 °C
Operating Temperature, Min -20 °C
Over-Voltage Protection Up to 60 vrms (rated for 30 seconds), protection against misconnection
RTD and OHMS Read Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 Accuracy: ± (0.015% of reading + 0.05Ω) Excitation Current: 0.9 mA to 401Ω, 0.4 mA to 4010Ω (nominal)
RTD and OHMS Source 3- and 4-Wire Accuracy: From 1 to 10.2 mA External Excitation Current: ± (0.015% of setting + 0.05Ω) Below 1 mA of External Excitation Current: Add (0.025 mV/mA excitation current) 2-Wire Accuracy: Add 0.1Ω to 3-wire and 4-wire accuracy Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 RMS Noise: 400Ω Range: ≤± 0.005Ω from 0.1 to 10 Hz 4000Ω Range: ≤± 0.05Ω from 0.1 to 10 Hz Allowable Excitation Current Range: 400Ω Range: 10.2 mA max; steady or pulsed/intermittent 4000Ω Range: 1 mA max; steady or pulsed/intermittent Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width, 0.025 mV, mA excitation current
Relative Humidity Note 10% ≤RH ≤90% (0 to 35°C),non-condensing; 10% ≤RH ≤70% (35 to 60°C),non-condensing
Relative Humidity, Max 0.9
Relative Humidity, Min 10%
Storage Temperature, Max 60 °C
Storage Temperature, Min -30 °C
Supply Voltage 6 Vdc
Temperature Effect ≤± 25 ppm/°C
Thermocouple Type J, K, T, E, R, S, B, C, N, L, G, U, D
Voltage Read Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of reading + 0.006 mV) Input resistance: ≥10 MΩ Normal Mode Rejection: 50/60 Hz,50 dB Common Mode Rejection: 50/60 Hz,120 dB
Voltage Source Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of setting + 0.006 mV) Source Current: ≥10 mA Output Impedance: <0.3Ω RMS Noise: ≤± 0.0005 mV from 0.1 to 10 Hz Short Circuit Duration: Infinite
Weight 0.34 kg
Weight Note 0.34 kg (12.1 oz) with boot and batteries
Width 76 mm
See All Specs Show Less
Calibrator for Thermocouple and RTDs (PT100) CL543B CL543B
  • y_2025, m_6, d_6, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_CL543B, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration