1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
FLD100-Series
Stainless Steel Frame Industrial Variable Area Flow Meters
Models In Stock
- Heavy Duty Stainless Steel
- Thick Polycarbonate Safety Shields
- Fluted or Plain Tapered Tubes
- Direct Reading Metric and English System Scales
FLD100-Series
From
$
857.85
Models In Stock

Product Overview
- Accuracy ± 3 %
- Materials, Wetted 316 Stainless Steel, Borosilicate, FKM
- Number of Tubes 1
- Operating Pressure Note Maximum Pressure: [at 93°C (200°F)] 200 psi (tube sizes 3, 4, 5 and 6); 125 psi (tube sizes 8 and 9)
- Process Connection Size 1/2 in
- Process Connection Type NPT Female
- Repeatability ± 0.5%
- Scale Direct Read
- Valve Included false
The FLD100 Heavy-duty flowmeters are fully enclosed in a brushed stainless steel case. Ideal for industrial applications with flow rates up to 116 GPM and 250 SCFM. Used with industrial water and air service. Meters are graduated for direct reading of water and air. Flow meters come with FNPT end fittings for easy in-line installation.
SPECIFICATIONS
Accuracy: ± 3% of full scale
Minimum Flow Rate: Approx. 10% of max flow rate
Repeatability: ± 0.5% of full scale
Max Pressure: [at 93°C (200°F)] 200 psi (tube sizes 3, 4, 5 and 6); 125 psi (tube sizes 8 and 9)
Max Operating Temperature: 93°C (200°F)
Wetted Parts: Include borosilicate glass flow tubes, FKM O-rings, and 316 SS fittings, guide rods, floats and float stops
Read More
Model No. | Max Flow Rate | ||||
Water GPM | AIR SCFM | Water L/min | Air L/min | Tube Size | |
FLD101 | 0.25 | 1.2 | 0.95 | 35 | 3 |
---|---|---|---|---|---|
FLD102 | 0.36 | 1.7 | 1.3 | 50 | 3 |
FLD103 | 0.76 | 3.3 | 3 | 90 | 3 |
FLD104 | 1 | 4.2 | 3.7 | 120 | 4 |
FLD105 | 1.5 | 6.5 | 5.6 | 180 | 4 |
FLD106 | 2.2 | 8.5 | 8.2 | 250 | 4 |
FLD107 | 3.8 | 16 | 14 | 475 | 5 |
FLD108 | 5 | 21.5 | 18 | 650 | 5 |
FLD109 | 6 | 25.5 | 20 | 725 | 6 |
FLD110 | 7.4 | 30 | 27.5 | 900 | 6 |
FLD111 | 9.6 | 40 | 35 | 1200 | 6 |
FLD112 | 11 | 47.5 | 40 | 1400 | 6 |
FLD113 | 14 | 62 | 50 | 1800 | 6 |
FLD114 | 20 | 90 | 75 | 2600 | 6 |
FLD115 | 22 | 90 | 83 | 2550 | 8 |
FLD116 | 26 | --- | 98 | --- | 6 |
FLD117 | 41 | 160 | 155 | 4531 | 9 |
FLD118 | 44 | 180 | 167 | 5098 | 8 |
FLD119 | 60 | 245 | 227 | 6938 | 9 |
FLD120 | 61 | 250 | 231 | 7080 | 8 |
FLD121 | 86 | --- | 326 | --- | 9 |
FLD122 | 116 | --- | 439 | --- | 9 |
Tube Size | FNPT |
3 and 4 | 1/2" |
5 and 6 | 1" |
8 and 9 | 2" |
SPECIFICATIONS
Accuracy: ± 3% of full scale
Minimum Flow Rate: Approx. 10% of max flow rate
Repeatability: ± 0.5% of full scale
Max Pressure: [at 93°C (200°F)] 200 psi (tube sizes 3, 4, 5 and 6); 125 psi (tube sizes 8 and 9)
Max Operating Temperature: 93°C (200°F)
Wetted Parts: Include borosilicate glass flow tubes, FKM O-rings, and 316 SS fittings, guide rods, floats and float stops
PDFs & Manuals