1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
DPG409S
Sanitary, High Accuracy, Digital Pressure Gauge with Output
- Easy to Read 25 mm (1') Backlit LCD Display
- High 0.08% Accuracy Typical
- Hi and Lo Alarms Standard
- MIN/MAX/AVG Reading
DPG409S
From
$
1,236.90

Product Overview
- Accuracy Class < 0.1%
- Accuracy Detail ± 0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined)
- Battery life 9 mo
- Battery Size and Type 3.6V Li-ion
- Burst Pressure 6x Full Scale
- Cable Length 2.7 m
- Calibration Note 5-Pt NIST traceable Calibration with zero and span values, Calibrated in horizontal direction (Compound Gage models calibrated in positive direction only)
- Compliance CE
- Connection Location Lower
- Data Interface USB
- Data Interface Note USB connection for set-up, cable included
- Display Segment Height 25 mm
- Display Type 4 Digit LCD
- Display Type Note 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height.
- Electrical Output 4 to 20 mA
- Electrical Output Note User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power required)
- Enclosure Material 316 Stainless Steel
- Enclosure Ratings IP65, NEMA Type 4X, Weatherproof
- Fill Fluid NEOBEE M5 food grade
- Isolation between Case and Output Terminations, Min 100MΩ @ 50 Vdc
- Materials, Wetted 316 Stainless Steel
- Number of Batteries 1
- Number of Digits 4
- Operating Temperature, Max 66 °C
- Operating Temperature, Min -18 °C
- Output Signal Current, Voltage
- Pressure Accuracy ± 0.08 %
- Pressure Cycles 250000
- Process Connection Note 11 ⁄2 and 2" Tri-GripTM Fitting (compatible with Tri-Clamp®): 600 psi using suitable clamp (600 psi on 11 ⁄2" Tri-Clamp® only)
- Process Connection Type Tri-Clamp
- Sample/Display Rate 0.25 to 10 sec
- Sample Display Rate Note User selectable from 0.25 to 10 sec. (preset to 1/sec)
- Sensor Dimension Note 72 to 89 mm L (2.8 to 3.5") below display
- Settable Parameters Backlight, Min, Max, Zero, Clear
- Software Settings Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _”
- Span Setting ± 0.5% FS typical ± 1% maximum (For ranges ≤2.5 psi ± 1% Typical ± 2% maximum)
- Storage Temperature, Max 82 °C
- Storage Temperature, Min -40 °C
- Supply Power Type Battery
- Thermal Effects Thermal Effect (Over Compensated Range): Zero and Span shift over Compensated Range; Ranges: ≤2.5 psi: Zero: 1.00% Span: 0.70% ;5 psi: Zero: 0.80% Span: 0.50% ; > 5 psi: Zero: 0.50% Span: 0.50% ; 26B & 26HB Barometric Range: Zero: 0.90% Span: 0.50%
- Weight 900 g
- Weight Note 900 g (2 lb) Typical depending upon configuration
- Wireless Option Specifications Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP, Vista Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level
- Zero/Balance Error ± 0.5% FS typical ± 1% maximum (For ranges ≤2.5 psi ± 1% Typical ± 2% maximum)
SPECIFICATIONS
RoHS Compliant
CE Compliant: Meets industrial emissions and immunity standard IEC61326 for industrial locations
Accuracy: ± 0.08% Best Straight Line Typ. (Linearity, Hysteresis and Repeatability combined)
Calibration: 5-Pt NIST traceable Calibration with zero and span values, Calibrated in horizontal direction (Compound Gage models calibrated in positive direction only).
Zero Balance: ± 0.5% FS typical ± 1% maximum (For ranges =2.5 psi ± 1% Typical ± 2% maximum)
Span Setting: ± 0.5% FS typical ± 1% maximum (For ranges =2.5 psi ± 1% Typical ± 2% maximum)
Storage/Operating Temperature Range:
Storage: -40 to 82°C (-40 to 180°F)
Operating: -18 to 66°C (0 to 150°F)
Compensated Temperature Range:
Ranges =5 psi: 4.4 to 60°C (40 to 140°F)
Ranges >5 psi: -4 to 85°C (25 to 150°F)
Thermal Effect (Over Compensated Range):
Zero and Span shift over Compensated Range
Ranges =2.5 psi: Zero: 1.00%
Span: 0.70%
Range = 5 psi: Zero: 0.80%
Span: 0.50%
Ranges > 5 psi: Zero: 0.50%
Span: 0.50%
26B & 26HB Barometric Range:
Zero: 0.90% Span: 0.50%
Minimum Isolation Between Case and Output Terminations: 100M O @ 50 Vdc
Analog Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc of 4 to 20 mA (external 24 Vdc power supply required for all analog output types)
Note: Compound gage ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc.
Analog Output Cable: 2.7 m (8.9')
Analog Output Accuracy: 0.08% typical
Pressure Cycles: 250,000, minimum
Long Term Stability (1-Year): ± 0.1% FS Typ.
Fill Fluid: NEOBEE M5 Food Grade
Approved to 3A Sanitary Specification
Environmental Protection: NEMA 4X (IP65) depending upon electrical termination
Pressure Rating: 1½ and 2' Tri-GripTM Fitting (compatible with Tri-Clamp®): 600 psi using suitable clamp (600 psi on 1½' Tri-Clamp®) only)
Over Pressure: 4 x rated pressure to maximum rated flange pressure
Secondary Containment: 6 x rated pressure to a maximum of 2000 psi (not in clamp)
Display: 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height
Computer Interface: UBS connection for set-up, cable included
Sample/Display Rate: User selectable from 0.25 to 10 sec. (preset to 1/sec)
Power: One 3.6V lithium 8.4 Ah capacity (C cell) Included (Two included with Wireless Option)
Battery Life (Typical): Up to 9 months
Enclosure Material: 316 Stainless Steel and ABS center gasket
Enclosure Finish: Brushed 316 stainless steel
Enclosure Environmental Rating: Weatherproof, NEMA 4X (IP65)
Connection Location: Lower (head rotates to position display)
Front Panel Functions
Backlight: Manually turns backlight on/off
Min/Max: Recalls min/max values
Zero/Clear: Zeros display or clears min/max
Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second
Units: psi, inHg, inH2O, bar, mbar, hPa, units must be specified at time of order
Lock: Allows the lock-out of front panel functions
Alarms: User selectable “High” and “Low” alarm limits. (Open Collector)
Analog Output: User Selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA (requires external 24 Vdc power)
Backlight: On/Off, 10 sec, 30 sec, 1 min, 5 min
Wireless Transmitter (optional): Channel Number, Transmission rate, alarms, sensor offset, chart recording, data logging
Calibrate: Zero and Span
Overrange Indication: “_ _ _ _”
Wireless Option Sepcifications
Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz
RF Output: 10 dBm (10 mW)
Range of RF Link:
Outdoors (Line of Sight): Up to 120 m (400')
Indoors/Urban: Up to 40 m (130')
Included Software: Requires Windows® 7 (32 bit); XP, Vista
Internal Battery: Two 3.6V lithium 8.4 Ah capacity (C-cell) included
Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level
Dimensions:
Display: 115 D x 89 W x 74 mm H (4.5 x 3.5 x 2.9')
Sensor: 72 to 89 mm L (2.8 to 3.5') below display
Weight: 900 g (2 lb) Typical depending upon configuration