RTD probes with 4 to 20 mA Analog Output and M12 Connector M12TX M12TX
loading all models
Product Overview
  • Accuracy Class A
  • Body Material Thermoplastic
  • Downscale 3.6 mA
  • Electrical Output 4 to 20 mA
  • EMC In accordance to EN 61326
  • Enclosure Ratings IP67
  • Enclosure Ratings Note IP65 and IP67 in accordance to IEC60529
  • Factory Setting 0 to 150°C/sensor break >21 mA (upscale)
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Permissible Load 700
  • Permissible Load Note 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
  • Process Connection Size N/A
  • Process Temperature, Max 500 °C
  • Process Temperature, Min -50 °C
  • Range Configurations Note It is possible set the input temperature range (span) by the M12TX-CONFIG-SETconfiguration kit (PC with OS Windows® required)
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Response Time < 50 ms
  • RTD Type 100 Ω Pt Sensor
  • Sensor Break Monitoring Note Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
  • Sensor Error Compensation Note Over 2 points (maximum 1% of span)
  • Series ID M12TX
  • Span, Min 50°C
  • Span Note 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
  • Supply Power Effects Negligible
  • Supply Voltage 8.5 to 32 Vdc
  • Temperature Influence, Max ± 0.3%
  • Temperature Influence Note Maximum of ± 0.3°C/25°C (77°F) or ± 0.3% of span/25°C (77°F)
  • Temperature Sensor Type RTD
  • Thermocouple Type N/A
  • Tmax. Electronic 80°C
  • Upscale 21 mA
  • Zero Setting Adjustable Range Any value between -50 to 50°C (-58 to 122°F)

Supported Applications

The Omega M12TX series consists of analog PC-programmable 2-wire transmitters with integrated Pt100 RTD sensors. Designed for space-limited areas, these compact mineral-insulated probes feature a molded IP67 connector and are intended for industrial temperature measurement applications where the electronic section must remain within -40 to +80°C.

Operating Conditions & Performance

The M12TX series provides a configurable input temperature range from -50 to 800°C via software, with standard factory defaults typically set for ranges such as 0 to 150°C. The Pt100 sensor (Pt-0.00385) meets Class A accuracy in accordance with IEC751 up to 300°C. Transmitter accuracy is specified at a maximum of ±0.2°C or ±0.2% of span.

Performance characteristics include:

  • Response Time (90%): <50 ms for the transmitter electronics.
  • Sensor Response Time (63.2%, test in water to IEC751): Less than 3.5 seconds for Ø3 mm probes and less than 13 seconds for Ø6 mm probes.
  • Ambient Temperature: -40 to +80°C (for the electronic section).
  • Process Temperature Limits: Up to 500°C (-58 to 932°F) is listed for standard operation; higher process temperatures up to 800°C are configurable but require adherence to Tmax./Tenv. graphs to prevent damage from heat transfer.
  • Humidity: 0 to 100% relative humidity.

Configuration Options

The series supports a wide envelope of configurations for probe diameter, insertion length, and output parameters. The transmitter is powered by an external supply or via the configuration interface during setup.

  • Sensor Element: 3-wire Pt100 (Pt-0.00385) with a sensor current of 0.5 mA; maximum wire resistance per wire is 20 Ω.
  • Output Signal: 4 to 20 mA analog output, non-isolated. Permissible load is 700Ω @24Vdc (calculated as R_load = (U - 8.5) / 0.022).
  • Power Supply: 8.5 to 32 Vdc with polarity protection.
  • Housing & Materials: Thermoplastic body for the transmitter section; probe sheath and thermowell options include AISI 316L stainless steel or compact mineral-insulated (MgO) cable construction.
  • Degree of Protection: IP65 and IP67 in accordance with IEC60529. The molded connector is M12x1 male, compliant with VDE0627.
  • Error Monitoring: Configurable sensor break monitoring (upscale >21 mA or downscale <3.6 mA) and fixed short-circuit action (downscale <3.6 mA).

Key Product Differences

Variants within the M12TX series are distinguished by probe diameter, insertion length, and specific model families.

  • Diameter Options: Probes are available in 3 mm (approx. 1/8") or 6 mm (approx. 1/4").
  • Length Configurations: Insertion lengths range from 100 mm to 1000 mm, with specific inch-based variants including 4", 6", 9", 12", 18", and 24".
  • Bending Radius: The compact mineral-insulated cable probe allows a minimum bending radius of three times the outer diameter (excluding the sensing tip).
  • Configuration Kit: Programming is performed using the M12TX-CONFIG-SET, which includes USB interface hardware and software for Windows 10.0 or higher to adjust range span, units (°C/°F/K), sensor error compensation, and transmitter identification.

Accessories

accessories

CONFIGURATION KIT FOR M12TX SENSORS
$510.34 / each
0 In Stock
Rated 5 out of 5 by from Excellent Temperature Probe We have been using this M12 Temperature Transmitter for 15 years and are very satisfy with the quality of this temperature probe.
Date published: 2025-11-18
  • y_2026, m_8, d_9, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_M12TX-PT100-1-4-10, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration