1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

I-7520-Series
RS-232 to RS-485 Converter, 3 kV Isolation
Modèles en stock
- Auto Switching Baud Rate, 300 to 115,200 bps
- 3000 VDC Isolation Protection on the RS-485 side
- Power Input, +10 to +30 VDC
- DIN-Rail Mountable
I-7520-Series
Depuis
$
182.00
Modèles en stock

L'aperçu du produit
- Status Control false
- Baud Rate 300 to 115200
- Baud Rate Note Max. 1,200 m for at speed 9.6 kbps; Max. 400 m at 115.2 kbps
- Cable Note Belden 8941 (2P twisted-pair cable)/Belden 8942 (4P twisted-pair cable), if different cables are used, the transmission distance may change
- Cable Type 2P Twisted-Pair Cable, 4P Twisted-Pair Cable
- Compliance UL94-V0
- Data Interface Note RS232: TxD, RxD, GND, RS485: Data+, Data-
- Height 4.8 in
- Input Cable Connector Type RS232: 9 - Pin Female D-Sub
- Input Type RS232
- Isolation Three Way Protection: 3000 Vdc
- LED Indicators Power/Communication LED
- Length 1.5 in
- Materials ABS
- Mounting DIN-Rail Mounting
- Number of Channels 1
- Operating Temperature, Max 75 °C
- Operating Temperature, Min -25 °C
- Output Cable Connector Type RS485: 2 Terminal Block 10-Pins, Removable
- Power Consumption 1.2 W
- Relative Humidity 10 to 90% RH, Non-Condensing
- Self Tuner Yes, Asic Inside
- Storage Temperature, Max 75 °C
- Storage Temperature, Min -30 °C
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Supported Devices 256 (Without repeater)
- Transmission Distance 4000 ft
- Width 2.83 in
Most industrial computer systems provide standard RS-232 serial ports. Though widely accepted, RS-232 has limited transmission speed, range, and networking capabilities. The RS-422 and RS-485 standards overcome these limitations by using differential voltage lines for data and control signals, which transparently converts RS-232 signals into isolated RS-422 or RS-485 signal with no need to change any hardware or software. The I-7520/I-7520A lets you easily build an industrial grade, long-distance communication system using standard PC hardware.
The design of the isolation between the I-7520 and the I-7520R/AR is different. If the user wants to supply power from the PLC/PC, the I-7520R/AR should be used, otherwise the isolation will be broken. Refer to the I-7000 bus converter manual for detailed information.
PDF et manuels
Afficher les notes et les avis
Do you have any sample source code?
Thank you for your question. There is no source for this device it is just a converter. Please download manual from the product page for detailed information.
Date published: 2022-03-23
Where is the Windows 11 driver for this device? I can only find Windows 7 drivers which do not work on W11.
. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2025-04-25