1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

U24Y175-Power-Supply
Regulated Power Supply for Transducers and Transmitters
- Rugged Power Supplies for Transducers and Transmitters
- 24 Vdc Regulated @ 175 mA Capacity
- 48 Vdc Unregulated @ 400 mA Capacity
- Economical Low Cost Solution

Product Overview
- Current Rating 175 mA
- Electrical Connection Screw Terminal
- Height 69 mm
- Isolated Analog Voltage 1500 Vdc
- Length 25 mm
- Line and Load Regulation ± 0.1 %
- Noise 3 mVrms
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -55 °C
- Short-Circuit Protected Current limited, overvoltage
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -10 °C
- Supply Power Note 105 to 125 or 210 to 250 Vac, user selectable
- Temperature Coefficient ±0.2% per °C
- Weight 283 g
- Width 76 mm
SPECIFICATIONS
U24Y175
Input: 105 to 125 or 210 to 250 Vac, user selectable
Operating Range: -10 to 65 °C (14 to 150 °F)
Storage Temperature: -55 to 85 °C (-67 to 185 °F)
Output: 24 Vdc at 175 mA max
Line and Load Regulation: ±0.1%
Ripple and Noise: 3 mV RMS
Temperature Coefficient: ±0.2% per °C
Dimensions: 69 H x 76 W x 25 mm D (2.7 x 3.0 x 1")
Output Protection: Current limited, overvoltage
Voltage Isolation: 1500 Vac
Weight: 283 g (10 oz)
U48Y40
Input: 110 Vac
Output: 48 Vdc at 400 mA
Operating Range: -10 to 65 °C (14 to 150 °F)
Dimensions: 114 H x 130 W x 87 mm D (4.49 x 5.12 x 3.44")
U24Y175
Input: 105 to 125 or 210 to 250 Vac, user selectable
Operating Range: -10 to 65 °C (14 to 150 °F)
Storage Temperature: -55 to 85 °C (-67 to 185 °F)
Output: 24 Vdc at 175 mA max
Line and Load Regulation: ±0.1%
Ripple and Noise: 3 mV RMS
Temperature Coefficient: ±0.2% per °C
Dimensions: 69 H x 76 W x 25 mm D (2.7 x 3.0 x 1")
Output Protection: Current limited, overvoltage
Voltage Isolation: 1500 Vac
Weight: 283 g (10 oz)
U48Y40
Input: 110 Vac
Output: 48 Vdc at 400 mA
Operating Range: -10 to 65 °C (14 to 150 °F)
Dimensions: 114 H x 130 W x 87 mm D (4.49 x 5.12 x 3.44")
PDFs & Manuals