1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
DP8PT
PLATINUM™ Series Digital Panel Meters
 
								Choose a Variant
Data Interface
		                
		                
		                            
		                Display Type
		                
		                
		                            
		                Control Output
		                
		                
		                            
		                Retransmission Output
		                
		                
		                            
		                
	Added to Your Shopping Cart
  Configuration complete.
Please add to cart to keep it or exit the configuration
		
		
		Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
		Product Specs
<< See all Product Models| Brand |  | 
| A/D Conversion | 24-bit sigma delta | 
| Accuracy | 0.03 % FS | 
| Additional Features 1 | Programmable 3 Color Display | 
| Approvals | UL, cUL, CE, UKCA | 
| CMRR | 120 dB | 
| Configuration | Differential | 
| Control Output | N/A | 
| Cutout Dimensions | 45 mm | 
| Data Interface | USB | 
| Data Interface Note | Ethernet Standards Compliance: IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET Protocols: OMEGA ASCII, MODBUS® ASCII/RTU | 
| Digital Filter | Programmable | 
| Display Range | -1999 to 9999 | 
| Display Size | 21 mm (.82 in) | 
| Display Type | 4 Digit LED | 
| Electrical Connection | USB 2.0 | 
| Enclosure Ratings | NEMA Type 1 | 
| External Fuse Required | Time-Delay, UL 248-14 Listed: 100 mA/250 V; 400 mA/250 V (low voltage option) ;Time-Lag, IEC 127-3 Recognized: 100 mA/250 V; 400 mA/250 V (low voltage option) | 
| Form factor | 1/8 DIN | 
| Frequency | 50 to 400 Hz | 
| Height | 48 mm | 
| Impedance Input | Process/Strain: 10M Ω for ±100 mV, 1M Ω for other voltage ranges ;Process Current: 5 Ω ;Thermocouple: 10K Ω max | 
| Input Current | 4 to 20 mA, 0 to 24 mA | 
| Input Type | Thermocouple, RTD, Thermistor, Current, Voltage, Strain | 
| Input Voltage | -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc | 
| Isolation | Power to Input/Output: 2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option) Power to Relays/SSR Outputs: 2300 Vac per 1 min test Relays/SSR to Relay/SSR Outputs: 2300 Vac per 1 min test RS232/RS485 to Inputs/Outputs: 500 Vac per 1 min test | 
| Length | 127 mm | 
| Measuring Range | Process Voltage: ±50 mV, ±100 mV, ±1, ±10 Vdc;Process Current: Scalable within 0 to 24 mA;Thermocouple;Type J: -210 to 1200 °C ;Type K: -270 to 160 °C and -160 to 1372 °C;Type T: -270 to -190 °C and -190 to 400 °C;Type E: -270 to -220 °C and -220 to 1000 °C;Type R: -50 to 40 °C and 40 to 1788 °C;Type S: -50 to 100 °C and 100 to 1768 °C;Type B: 100 to 640 °C and 640 to 1820 °C;Type C: 0 to 2320 °C;Type N: -250 to -100 °C and -100 to 1300 °C;RTD;Pt, 0.00385, 100 Ω, 500 Ω, 1000 Ω: -200 to 850 °C;Pt, 0.003916, 100 Ω: -200 to 660 °C;Pt, 0.00392, 100 Ω : -200 to 660 °C;Thermistor;2252 Ω: -40 to 120 °C;5K Ω: -30 to 140 °C;10K Ω: -20 to 150 °C | 
| Number of Inputs | 1 | 
| Operating Temperature Note | 0 to 50°C (32 to 122°F), 90% RH non-condensing | 
| Operating Temperature, Max | 50 °C | 
| Operating Temperature, Min | 0 °C | 
| Polarity | Bipolar | 
| Power Consumption | 4 W | 
| RTD Input Range | 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves | 
| Reading Rate | 20/sec | 
| Relative Humidity | 0.9 | 
| Resolution | 0.1° temperature; 10 µV process | 
| Retransmission Output | N/A | 
| Sampling Rate | 20 Hz (20 updates/second) | 
| Sensor/Transmitter Power | 5, 10, 12 and 24 Vdc @ 25 mA | 
| Sensor/Transmitter Power Note | Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 Vdc @ 25 mA | 
| Strain Input | ± 50 mV, ± 100 mV | 
| Supply Power Note | 90 to 240 Vac ±10%, 50 to 400 Hz*, 110 to 375 Vdc, equivalent voltage | 
| Supply Power Type | AC | 
| Supply Voltage | 90 to 240 Vac | 
| Temperature Stability | RTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C | 
| Thermistor Input Range | 2252 Ω, 5K Ω, 10K Ω | 
| Thermocouple Type | J, K, T, E, R, S, B, C, N | 
| Warm Up Time | 30 mins | 
| Weight | 295 g | 
| Width | 48 mm | 
| See All Specs | |
				PDFs & Manuals
			
		
				Software & Drivers
			
		Accessories
cables
meters/controllers
Show Ratings & Reviews
 
			
	
	
	
        
            Rated 4 out of
            5
         by
        JonT from
        Basic DAQ
        For a basic data acquisition this part works fine.  I had to call into omega for help navigating the menu to get the scaling correct for the 4-20mA, 0-1000psi pressure transducer.   If all you need to do is acquire and log data from display this part is just fine.
        
    Date published: 2018-05-23
        
    
        
            Rated 5 out of
            5
         by
        Kevinn from
        Gets the job done
        Needed to connect different pressure transducer types.  The set up was a bit confusing (always hate 100+ page manuals) but tech support was able to assist with no problems.  All issues were resolved.
        
    Date published: 2018-11-08
        
    
        
            Rated 1 out of
            5
         by
        BURT from
        UNHAPPY
        VERY HARD TO PROGRAM NO BASIC EXAMPLE PROGRAM. PLAN TO SPEND DAYS PROGRAMMING
        
    Date published: 2018-03-08
        
    
        
            Rated 5 out of
            5
         by
        Mazi from
        SERAIL COMMUNICATION
        We have a DP8EPT-006 (Serial #  M20430706). We want to know if we can get a serial output from this panel.
        
    Date published: 2024-07-22
        
    
        
            Rated 5 out of
            5
         by
        Julian Mesa from
        Purchasing Agent
        Works flawlessly and was delivered in a quick manner!
        
    Date published: 2024-05-13
        
    
        
            Rated 5 out of
            5
         by
        GWILLIAMS from
        PLATINUM DIGITAL METERS
        These digital meters were a perfect match and were received in a timely manner.
        
    Date published: 2023-11-17
        
    
        
            Rated 5 out of
            5
         by
        Mohamed Kandil from
        Good product
        The meter quality is good and installation instruction is clear
        
    Date published: 2023-10-03
        
    
        
            Rated 4 out of
            5
         by
        Ted Bellanger from
        Digital meter
        Meter was easy to set up. Display of numbers were is to read
        
Date published: 2023-05-08
        
     
						
						 
					
				